Log:
valutazioni - 4, GPA: 4.5 ( )

Istruzioni per l'uso Monessen Hearth, Modello N/PE7

Produttore : Monessen Hearth
File Size : 3.98 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


In Canada CSA-B149 (1 or 2) Installation Code. CAUTION A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8" NPT pressure tapping point should be installed upstream of the appliance. Figure 41 IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the fireplace. Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces. Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged burner system valve. Use pipe joint sealant that is resistant to liquid petroleum (LP) gas. We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 41. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap collects moisture and contaminants and keeps them from going into the burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system may not run properly. 3" MinimumFP1978gas connection CSA Design-Certified Equipment Shutoff Valve with 1/8" NPT Tap* Approved Flexible Gas Line Natural Gas From Gas Meter (4.5" w.c. to 10.5" w.c. Pressure) Propane/LP From External Regulator (11" w.c. to 13" w.c. Pressure) Tee Joint Sediment Trap/Drip Leg Pipe Nipple Cap Figure 41 - Gas Connection CHECK GAS PRESSURE & Electrical installation 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately. 2. To ease installation, a 30" (mm) flex line with manual shut- off valve has been provided with this appliance. Install and attach 1/2" gas line onto shut-off valve. 3. After completing gas line connection, purge air from gas line and test all gas joints from the gas meter to the fireplace for leaks. Use a solution of 50/50 water and soap or a gas sniffer. 4. To adjust flame height, turn HI/LO knob to HI to get maximum pressure to burner. Turn HI/LO knob to LO to get minimum pressure. 5. To check gas pressures at valve, turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point. Turn unit to high. Figure 42. After taking pressure reading, be sure and turn captured screw clockwise firmly to reseal. Do not over torque. Check test points for gas leaks. FP1979Millivolt gas valve Pressure Test “IN” Pressure Test “OUT” FP1979 HI/LO Knob Pilot Adjustment Screw Figure 42 - Gas Pressure Check at Gas Valve WARNING Do not use open flame to check for gas leaks. Electrical Wiring This fireplace will work without any electrical supply. Electricity is only needed to operate blower. NOTE: If installed in mobile home, fireplace must be bolted securely to floor. WARNING CAUTION Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service. All wiring shall be in compliance with all local, city and state codes. The appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes, with the National Electrical Code ANSI/NFPA 70 (latest edition) and Canadian Electrical Code, CSA C22.1. Label all wires before disconnecting when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Electrical installation FP2284aCDV7 controls Remote Wall mounted Switch A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 43. Do not extend beyond the wall switch wire length provided. NOTE: Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local code. WARNING Do not connect wall switch to (110 V) circuit. ONOFFOPTIONAL REMOTEWALL SWITCHONOFFOPTIONAL REMOTECONTROL RECEIVERPILOTHILOONOFFTHTPTH/TPONOFFRSFP1980Dv wiring diagram Figure 43 - Wiring Diagram for Wall Switch Remote Wall Switch Position the wall switch. Do not extend beyond the 15 feet of wire. Optional DC Remote Systems See section entitled Hearth Mount in the Millivolt hand held remote instructions supplied with the remote. 1. Using a flat head screw driver, bend the “remote” tabs up from the bottom of the fireplace. Figure 44 2. Follow the instructions on remote control to snap the remote cover plate to the remote receiver 3. Connect the wire terminal from the remote receiver. Figure 43 4. Use the screws that came with the ...

Questo manuale è adatto anche per i modelli :
Camini - CDV7 (3.98 mb)
Camini - CDVR33N/PV7 (3.98 mb)
Camini - N/PSC7 (3.98 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie