Log:
valutazioni - 2, GPA: 4 ( )

Istruzioni per l'uso Heat & Glo LifeStyle, Modello SL-750TV-IPI-E

Produttore : Heat & Glo LifeStyle
File Size : 4.5 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


The fireplace should be inspected before use and at least annually by a professional service person. The following tasks may be performed annually by the homeowner. If you are uncomfortable performing any of the listed tasks, please call your dealer for a service appointment. More frequent cleaning may be required due to lint from carpeting or other factors. Control compartment, burner and circulating air passageway of the fireplace must be kept clean. CAUTION! Risk of Burns! The fireplace should be turned off and cooled before servicing. Glass Cleaning Frequency: Seasonally By: Homeowner Tools Needed: Protective gloves, glass cleaner, drop cloth and a stable work surface. CAUTION! Handle fixed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slamming glass • Avoid abrasive cleaners • DO NOT clean glass while it is hot • Prepare a work area large enough to accommodate fixed glass assembly and door frame by placing a drop cloth on a flat, stable surface. Note: Fixed glass assembly and gasketing may have residue that can stain carpeting or floor surfaces. • Remove door or decorative front from fireplace and set aside on work surface. • See Section 14.G for instructions to remove fixed glass assembly. • Clean glass with a non-abrasive commercially available cleaner. - Light deposits: Use a soft cloth with soap and water - Heavy deposits: Use commercial fireplace glass cleaner (consult with your dealer) • Carefully set fixed glass assembly in place on fireplace. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Doors, Surrounds, Fronts Frequency: Annually By: Homeowner Tools needed: Protective gloves, stable work surface • Assess condition of screen and replace as necessary. • Inspect for scratches, dents or other damage and repair as necessary. • Check that louvers are not blocked. • Vacuum and dust surfaces. Remote Control Frequency: Seasonally By: Homeowner Tools needed: Replacement batteries and remote con trol instructions. • Locate remote control transmitter and receiver. • Verify operation of remote. Refer to remote control operation instructions for proper calibration and setup procedure. • Place batteries as needed in remote transmitters and battery-powered receivers. • Place remote control out of reach of children. If not using your fireplace for an extended period of time (summer months, vacations/trips, etc), to prevent unintended operation: • Remove batteries from remote controls. • Unplug 3 volt adapter plug on IPI models. Heat & Glo • SL-550 / 750 / 950TV-IPI-E • 2119-900 Rev. J • 12/09 Venting Frequency: Seasonally By: Homeowner Tools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow, debris, etc. • Verify termination cap clearance to subsequent construction. See Section 6. • Inspect for corrosion or separation. • Verify weather stripping, sealing and fl ashing remains intact. • Inspect draft shield to verify it is not damaged or missing. B. Maintenance Tasks-Qualifi ed Service Technician The following tasks must be performed by a qualifi ed service technician. Gasket Seal and Glass Assembly Inspection Frequency: Annually By: Qualifi ed Service Technician Tools needed: Protective gloves, drop cloth and a stable work surface. • Inspect gasket seal and its condition. • Inspect fixed glass assembly for scratches and nicks that can lead to breakage when exposed to heat. • Confirm there is no damage to glass or glass frame. Replace as necessary. • Verify that fixed glass assembly is properly retained and attachment components are intact and not damaged. Replace as necessary. Logs Frequency: Annually By: Qualifi ed Service Technician Tools needed: Protective gloves. • Inspect for damaged or missing logs. Replace as necessary. Refer to Section 14 for log placement instructions. • Verify correct log placement and no fl ame impingement causing sooting. Correct as necessary. Firebox Frequency: Annually By: Qualifi ed Service Technician Tools needed: Protective gloves, sandpaper, steel wool, cloths, mineral spirits, primer and touch-up paint. • Inspect for paint condition, warped surfaces, corrosion or perforation. Sand and repaint as necessary. • Replace fi replace if firebox has been perforated. Control Compartment and Firebox Top Frequency: Annually By: Qualifi ed Service Technician Tools needed: Protective gloves, vacuum cleaner, dust cloths • Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided. • Remove all foreign objects. • Verify unobstructed air circulation. Burner Ignition and Operation Frequency: Annually By: Qualifi ed Service Technician Tools needed: Protective gloves, vacuum cleaner, whisk broom, flashlight, voltmeter, indexed drill bit set, and a manometer. • Verify burner is pr...

Questo manuale è adatto anche per i modelli :
Camini - SL-550TV-IPI-E (4.5 mb)
Camini - SL-950TV-IPI-E (4.5 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie