Log:
valutazioni - 2, GPA: 3 ( )

Istruzioni per l'uso Heat & Glo LifeStyle, Modello PIER-HV-IPI

Produttore : Heat & Glo LifeStyle
File Size : 3.11 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


The information contained in this Installers Guide, unless noted otherwise, applies to all models and gas control systems. Gas fireplace diagrams, including the dimensions, are shown in this section. Pre-install Preparation This gas fireplace and its components are tested and safe when installed in accordance with this Installers Guide. Report to your dealer any parts damaged in shipment, particularly the condition of the glass. Do not install any unit with damaged, incomplete, or substitute parts. The vent system components are shipped in separate packages. The gas logs are packaged separately and must be field installed. Read all of the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety and benefit. Failure to follow these instructions will void the owner’s warranty and may present a fire hazard. The Heat & Glo Warranty will be voided by, and Heat & Glo disclaims any responsibility for, the following actions: • Installation of any damaged fireplace or vent system component. • Modification of the fireplace or direct vent system. • Installation other than as instructed by Heat & Glo. • Improper positioning of the gas logs or the glass door. • Installation and/or use of any component part not manufactured and approved by Heat & Glo, not withstanding any independent testing laboratory or other party approval of such component part or accessory. ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE HAZARD. When planning a fireplace installation, it’s necessary to determine: • Where the unit is to be installed. • The vent system configuration to be used. • Gas supply piping. • Electrical wiring. • Framing and finishing details. • Whether optional accessories—devices such as a fan, wall switch, or remote control—are desired. If the fireplace is to be installed on carpeting or tile, or on any combustible material other than wood flooring, the fireplace should be installed on a metal or wood panel that extends the full width and depth of the fireplace. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 16 Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 Figure 1. Diagram of the PIER-HV-IPI 5-1/4 (133mm) 1/2 (13mm) 12 (306mm) O8 (205mm) 42-5/8 O8 (1082mm) (205mm) 12 (305mm) ELECTRICAL ACCESS GAS LINE 34-3/4 ACCESS (883mm) 4-1/16 (102mm) 4-1/2 (114mm) 4-3/4 (121mm) 2-5/16 (58mm) 37-7/16 (950mm) 17-15/16 (455mm) 24 (610mm) 21-9/16 (547mm) 32-5/16 (820mm) 21-9/16 (547mm) 42 (1067mm) REAR VENT COLLARS ELECTRICAL ACCESS GAS LINE ACCESS GAS CONTROLS & LABELS SIDE GLASS DOOR TOP STANDOFFS TOP VENT COLLARS Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 17 Figure 2. Diagram of the ST-HV-IPI 5-14 (133mm) 12 (306mm) 1/2 (13mm) (4) 46-5/8 (1183mm) 42 (1067mm) 32-5/16 (821mm) 21-9/16 (548mm) 36-3/16 (919mm) 2-5/16 (58mm) 4-3/4 (121mm) 4-1/16 (102mm) 4-1/2 (114mm) ELECTRICAL ACCESS GAS LINE ACCESS 12 (305mm) 4-1/2 (114mm) 2-9/16 (64mm) 24 (610mm) 8-1/2 (216mm) 34-3/4 (882mm) O8 (205mm) O8 (205mm) REAR VENT COLLARS ELECTRICAL ACCESS GAS LINE ACCESS GAS CONTROLS & LABELS SIDE GLASS DOOR TOP STANDOFFS TOP VENT COLLARS 18 Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 Figure 3. Diagram of the LCOR-HV-IPI and RCOR-HV-IPI 5-1/4 (133mm) 1/2 (13mm) (4) O8 (205mm) 12-1/16 (306mm) 12 O8 (305mm) (205mm) 34-3/4 (882mm) 10 (254mm) 7-1/4 (184mm) 4-3/4 (121mm) 32-5/16 (821mm) 37-7/16 (950mm) ELECTRICAL ACCESS GAS LINE ACCESS 42-5/8 (1083mm 2-9/16 (64mm) 2-5/16 (58mm) 17-15/16 (455mm) 21-9/16 (547mm) 24-1/8 (612mm) 29-1/4 (743mm) 42 (1067mm) 21-9/16 (548mm) REAR VENT COLLARS ELECTRICAL ACCESS GAS LINE ACCESS GAS CONTROLS & LABELS END GLASS DOOR TOP VENT TOP STANDOFFS COLLARS SIDE GLASS DOOR Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06 19 3Installing the Fireplace Step 1. Locating the Fireplace The diagram below shows space and clearance requirements for locating a fireplace within a room. Figure 4A. Fireplace Dimensions and Locations 36" GLASS GLASS GLASS 36" GLASS GLASS 36" GLASS 36" GLASS GLASS GLASS 36" 36" 36" PIER-HV-IPI TOP VIEW RCOR-HV-IPI TOP VIEW LCOR-HV-IPI TOP VIEW ST-HV-IPI TOP VIEW Clearance Requirements The top, back, and sides of the fireplace are defined by stand-offs. The minimum clearance to a perpendicular wall extending past the face of the fireplace is one inch (25 mm). The metal ends of the fireplace may NOT be recessed into combustible construction. Note: Refer to Figure 4B for dimensions and appliance locations if installing a Pier-HV unit with a Catalina shelf and/or marble package. Note: Refer to the Catalina installation instruction included with kit for assembly and installation. Figure 4B. 50-1/2 in. 34-1/2 in. 7 in. 47-1/2 in. 45-1/4 in. 13/16 in. Marble sizes (inches): Header .................................. 26 x 8 Side headers .................. 45-1/2 x 8 Legs ................................ 3...

Questo manuale è adatto anche per i modelli :
Camini - LCOR-HV-IPI (3.11 mb)
Camini - RCOR-HV-IPI (3.11 mb)
Camini - ST-HV-IPI (3.11 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie