|
Facilità d'uso
These fireplaces must be vented directly to the outside. The vent system may not service multiple appliances, and must never be connected to a flue serving a solid fuel burning appliance. The vent pipe is tested to be run inside an enclosing wall (such as a chase). There is no requirement for inspection openings in the enclosing wall at any of the joints in the vent pipe. Preparing the Appliance Vent Collar on D-500/600/800 Series (Combined Top and Rear Vent) Models Each of the unit's two vent collars are sealed with a cover plate and a seal plate and gasket. The cover, and seal plate and gasket must be removed from the vent collar being used. Refer to Figure 13 for top vent usage and Figure 14 for rear, and the following steps to prepare the appropriate collar for use. From the vent collar being used, remove the four screws securing the vent seal plate and gasket. Remove and discard the seal plate and gasket. When the top vent collar is being used, from inside the firebox, loosen the two screws in the keyhole slots of the cover plate and remove the remaining two cover plate securing screws. Remove and discard the cover plate. Reinstall and securely tighten all four screws. When the rear vent collar is being used, from inside the firebox, remove the two screws securing the lintel to the rear wall of the firebox, then remove the lintel. Remove the four cover plate securing screws. Remove and discard the cover plate. Reinstall and securely tighten all four cover plate screws. Re-secure the lintel to the rear wall of the firebox. WARNING: FAILURE TO REINSTALL AND SECURELY TIGHTEN COVER PLATE SCREWS COULD RESULT IN LEAKAGE OF FLUE PRODUCTS INTO THE LIVING SPACE. VENT COVER PLATE AND VENT SEAL PLATE MUST REMAIN SECURELY INSTALLED ON UNUSED VENT COLLAR. FAILURE TO DO SO COULD RESULT IN LEAKAGE OF FLUE PRODUCTS INTO LIVING SPACE. VENT SEAL PLATE GASKET FIREBOX TOP CABINET TOP SECURING SCREWS VENT COVER PLATE TOP VENT ON D-500/600/800 SERIES MODELS(COMBINED TOP AND REAR VENT UNITS) TOP VENT SEAL & COVER PLATE REMOVAL WHEN USING THE TOP VENT COVER PLATE SECURING SCREWS CROSS SECTION(INSIDE UNIT) (OUTSIDE UNIT) Figure 13 VENT SEAL PLATE GASKET SECURING SCREWS CROSS SECTION LINTEL SECURING SCREWS LINTEL REAR VENT COVER PLATE SECURING SCREWS ON D-500/600/800 SERIES MODELS(COMBINED TOP AND REAR VENT UNITS) REAR VENT SEAL & COVER PLATE REMOVAL WHEN USING THE REAR VENT CABINET BACK (INSIDE UNIT) (OUTSIDE UNIT) Figure 14 Installation of Vent Restrictor A vent restrictor may be needed with this appliance, install the vent restrictor (provided) in the appliance top flue outlet as shown in Figure 15 or rear flue outlet as shown in Figure 16. It is held in place by friction, only. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. A vent restrictor may be needed when vertically terminating the vent system above the roof (when using the appliance topvent), install vent restrictor in the top vent of the fireplace outlet on D-500/600/800 and DT-500/600/800 series models. RESTRICTOR APPLIANCE TOP VENT OUTLET VENT RESTRICTOR INSTALLATION (TOP VENT) If needed, install the restrictor orientated as shown, either from inside or outside the unit, in the inner fireplace collar. INNER FIREPLACE COLLAR Figure 15 RESTRICTOR APPLIANCE REAR VENT OUTLET A vent restrictor may be needed when horzontally terminating the vent systemfrom the rear of the appliance (when using the applliance rear vent), install vent restrictor in the rear vent of the fireplaceoutlet on D-500/600/800 and DR-500/600/800 series models, in any installation that has a vertical vent run in excess of three feet (0.914 meters). VENT RESTRICTOR INSTALLATION (REAR VENT) INNER FIREPLACE COLLAR If needed, install the restrictor orientated as shown, either from inside or outside the unit, in the inner fireplace collar. Figure 16 Select Venting System - Horizontal or Vertical With the appliance secured in framing, determine vent routing and identify the exterior termination location. The following sections describe vertical (roof) and horizontal (exterior wall) vent applications. Refer to the section relating to your installation. A list of approved venting components is shown in the two tables on page 24 and the two tables on page 25. VENT SECTION LENGTH CHART VENT SECTION LENGTH CHART Nominal Section Length (inches) 6 12 24 36 48 T O T A L QT Y Nominal Section Length (inches) 6 12 24 36 48 T O T A L QT Y SectionNet Length (inches) 4-1/2 10-1/2 22-1/2 34-1/2 46-1/2 SectionNet Length (inches) 4-1/2 10-1/2 22-1/2 34-1/2 46-1/2 Height of Vent Number of Vent Sections Height of Vent Number of Vent Sections inches ft inches ft 4.5 0.375 1 0 0 0 0 1 144 12 1 0 0 0 3 4 9 0.75 2 0 0 0 0 2 150 12.5 0 1 0 0 3 4 10.5 0.875 0 1 0 0 0 1 154.5 12.875 1 1 0 0 3 5 15 1.25 1 1 0 0 0 2 160.5 13.375 0 2 0 0 3 5 19.5 1.625 2 1 0 0 0 3 172.5 14.375 0 0 0 5 0 5 21 22.5 1.75 1.875 0 0 2 0 0 1 0 0 0 0 2 1 177 183 14.75 15.25 1 0 0 1 0 0 5 5 0 0 6 6 31.5 25.5 2.625 2.125 0 1 3 2 0 0 0 0 0 0 3 3 186 15.5 0 0 0 0...
Questo manuale è adatto anche per i modelli :Camini - 500 (976.79 kb)
Camini - 600 (976.79 kb)