|
Facilità d'uso
WARNING: Use solid wood or processed solid fuel firelogs only. When processed wood fuel fire logs are used, do not poke or stir the logs while they are burning. Use only fire logs that have been evaluated for the application in fireplace and refer to fire log warnings and caution markings on packaging prior to use. WARNING: Always leave glass doors fully opened or fully closed when operating fireplace. 109493-01N Specifications 42" Models 10.5" 17" 0.625" 51" 30.5" 28.5" 21.25" 41.25" 23.5" 24.25" 3.5" 13" 1" 49" 8" 58" 30" 42" 51" 12" 9.5" 8.5" 67" 11" GAS LINE KNOCK OUTS AIR KIT KNOCK OUT LEFT SIDE OUTSIDE AIR11/2" AIR SPACE BACK AND SIDES 0" TOBOTTOMGAS LINEKNOCKOUTS12" EACH SIDE COMBUSTIBLE WALL BOARD NO COMBUSTIBLEMATERIAL ON FACEMINIMUM 18" TO PERPENDICULAR SIDEWALL HEARTH EXTENSION66" X 20" 2" CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL ROUND TOP TERMINATION TERMINATION SQUARE CHASE-TOP Specifications 50" Models 10.5" 17" 50" 23.5" 32.75" 3.5" 13" 9.5" 8.5" 2" CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL TERMINATION SQUARE CHASE-TOP ROUND TOP TERMINATION COMBUSTIBLE WALL BOARD NO COMBUSTIBLE MATERIAL ON FACE 0" TOBOTTOMOUTSIDE AIR11/2" AIR SPACE BACK AND SIDES GAS LINEKNOCKOUTS12" EACH SIDE MINIMUM 18" TO PERPENDICULAR SIDEWALL HEARTH EXTENSION 74" X 20" 0.625" 59" 38.5" 28.5" 21.25" 11" 1" 49" 8" 58" 30" 50" 59" 12" 67" LEFT SIDE GAS LINE KNOCK OUTS AIR KIT KNOCK OUT Fireplace Installation selecting location To determine the safest and most efficient location for the fireplace, you must take into consideration the following guidelines: 1. The location must allow for proper clearances (see Figures 1 and 2). 2. Consider a location where the fireplace will not be affected by drafts, air conditioning ducts, windows or doors. 3. A location that avoids the cutting of joists or roof rafters will make installation easier. 4. An outside air kit is available with this fireplace (see Optional Outside Air Kit on page 6). Minimum clearance to combustibles Back and sides of fireplace 1 1/2" min.* Front of fireplace 48" min. Floor** 0" min. Perpendicular wall to opening 12" min. Top spacers 0" min. Mantel clearance see Mantels, page 5 Chimney outer pipe surface 2" min. * Not required at nailing flanges ** See step 2 of Framing WARNING: Do not pack required air spaces with insulation or other materials. Minimum/Maximum Chimney Height The minimum height of the chimney, measured from the base of the fireplace to the flue gas outlet of the termination, is 16 feet for straight flue or a flue with one elbow set. The maximum distance between elbows is 6 feet. For systems with two elbow sets, the minimum height is 22 feet. The maximum height of any system is 50 feet. This measurement includes the fireplace, chimney sections and the height of the termination assembly at the level of the flue gas outlet (see Figure 15, page 9). Framing 1. Frame the opening for the fireplace using the dimensions shown in Figures 1 and 2. 2. If the fireplace is to be installed directly on carpeting, tile (other than ceramic) or any combustible material other than wood flooring, the fireplace must be installed upon a metal or wood panel extending the full width and depth of the fireplace. 3. Set the fireplace directly in front of this opening and slide the unit back until the nailing flanges touch the side framing. 4. Check the level of the fireplace and shim with sheet metal if necessary. 5. Before securing fireplace to prepared framing, the ember protector (provided) must be placed between the hearth extension (not supplied) and under the bottom front edge of the fireplace to protect against glowing embers falling through. If the fireplace is to be installed on a raised platform, a Z-type ember protector (not supplied) must be fabricated to fit your required platform height. The ember protector should extend under the fireplace a minimum of 1 1/2". The ember protector should be made of galvanized sheet metal (28 gauge minimum to prevent corrosion. 6. Using screws or nails, secure the fireplace to the framing through flanges located on the sides of the fireplace. 30.125" 58.125" 67.125" 51.25" (42") 59" (50") Figure 1 - Framing Dimensions 92" (42" Models) 100" (50" Models) 65" (42" Models) 71" (50" Models) Maintain 1 1/2" Clearance at Sidesand Back of Fireplace1 1/2" ClearanceNot Required at Nailing Flanges Figure 2 - Corner Installation Hearth Extension A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of the fireplace opening is required to protect combustible floor construction in front of the fireplace. Fabricate a hearth extension using a material which meets the following specifications: a layer of noncombustible, inorganic material having a thermal conductivity of K=0.84 BTU IN/FT, HR. F (or less) at 1" thick. For example, if the material selected has a K factor of 0.25, such as glass fiber, the following formula would apply: 0.25 x 1.0" = 0.30" thickness req...
Questo manuale è adatto anche per i modelli :Camini - (V)G42/50 (1.14 mb)
Camini - (V)G42H/50H (1.14 mb)
Camini - (V)G42R/50R (1.14 mb)