Facilità d'uso
1. Open the top lid. Clear all foreign objects and shipping materials from the hopper compartment and the entrance to the grind chamber. 2. Tip the machine gently, on its back, so it rests with approximately one inch of the bottom overhanging the work surface. 3. Remove the drawer from the base assembly. 4. Place the base against the grinder bottom and align the four sets of holes. 5. Securely fasten the base to the grinder bottom using the four screws and washers provided. 6. Raise the grinder to the upright position. 7. Insert the drawer into the base assembly. 8. The grinder can now be plugged-in and put into service. OPERATING CONTROLS Off/On/Start Switch OFF - (upper position) Switching to this position stops the operation of the grinder. ON - (center, resting position) The switch will return to this position after a grind cycle has begun and will remain in this position after grinding has ceased. START - (lower, momentary position) Pressing the switch initiates grinding only when a bag is in place behind the chute. Grind Selector Allows the user to vary the grind for each bag of coffee. Each setting will provide precisely the same grind every time it is selected. Bag Sensor Prevents the grinder from operating unless the back of a bag is in place behind the dispense chute. Do not attempt to bypass this safety device. 10191 062309 4 CLEANING WARNING - Unplug the grinder before the removal of any panel or grind chamber-housing parts. 1. Clean all exterior surfaces using a damp cloth rinsed in any mild, nonabrasive, liquid detergent. Care should be taken not to scratch the grinder with any abrasive material. 2. Empty all beans from hopper(s). Plug in the grinder, place an empty bag behind the dispense chute. Press and release the “START” switch. Run a few cycles until all coffee in the grind chamber is dispensed and disconnect the grinder from the power source. Remove the bag. WARNING - Prior to cleaning the grind chamber, unplug the grinder. 3. Remove the two screws and remove the dial plate and selector knob assembly. 4. Slide the burr auger rotor/spring assembly off the motor shaft and disassemble for cleaning. 5. Remove the two screws securing the stationary burr to the grind chamber. 6. Remove the four screws at the top of the chute and remove the chute. Using a pair of pliers, remove the C- clips securing the flapper arm to the chute. Remove the flapper securing pins carefully (noting the location of each flapper spring). 7. Wash all parts in a mild solution of detergent with hot water and a stiff non-metallic bristle brush. Rinse all parts thoroughly and allow them to air dry before reinstalling. 8. Carefully clean the grind chamber, dial plate assembly, chute opening and dial plate opening with a dry stiff non-metallic bristle brush. Wipe with a clean cloth that has been soaking in a mild solution of detergent and hot water. Reinstall the spring and rotor with burr onto the motor shaft. 9. Align the slot in the motor shaft with the rotor and reinstall shear plate. Reinstall rotor cup and grind selector dial plate to the burr housing. Refer to the “Adjustment” section of the Operating and Service manual for burr adjustments. 10191 113007 5 COFFEE GRINDING 1. Turn the selector knob to align the red arrow with the desired grind. 2. Raise the top lid and add the whole bean coffee. Close the top lid. 3. Locate the back of a bag behind the dispense chute. (The grinder will not operate unless the bag is behind the chute.) 4. Allow the bag to rest on the screen beneath the chute. 5. Press the start switch. 6. Flip the cleaning lever a few times as dispensing slows. 7. Remove the bag when ground coffee is no longer dispensed from the chute. The grinder will stop automatically as the bag is removed. NOTE - The start switch will have to be pressed again to continue the cycle if the bag is removed while grinding. ADJUSTMENT 1. Place an empty bag on the screen, with the back of the bag behind the dispense chute. 2. Start the grinder to clear the grind chamber. Leave grinder “ON”. 3. Turn the Grind Selector knob to the “TURKISH” (fully clockwise) position. 4. Using a small flat blade screwdriver, loosen the two set screws on the left side of the grind selector knob. 5. Hold the knob in the “TURKISH” (fully clockwise) position with one hand. 6. Using a large flat blade screwdriver, slowly turn the adjusting screw in the center of the grind selector knob to the right (clockwise) until a metallic whine can be heard due to the rubbing of the grinding burrs. 7. While holding the knob in the “TURKISH” (fully clockwise) position, back off the screw to the left (counterclockwise) just until the metallic whine ceases. 8. Turn-off the grinder. 9. Push the knob against the dial plate and tighten both set screws on the left side of the grind selector knob. 10. Turn the grinder on and listen again for the metallic whine with the grind selector knob in the turkish (fully clockwise) position. If the metallic whine is heard, r...