Log:
valutazioni - 3, GPA: 3.7 ( )

Istruzioni per l'uso Lenmar Enterprises, Modello 32354

Produttore : Lenmar Enterprises
File Size : 5.94 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Not all keyboards report country information and two different styles of keyboard may be connected to the LINDY CPU Switch. Consequently in AUTOMATIC mode the LINDY CPU Switch will attempt to query both the keyboards that are attached to try and find a country code (user port 1 is tested first). If a country code is not found then the LINDY CPU Switch will use the DEFAULT COUNTRY code specified by the user. In MANUAL mode, the connected keyboards are not queried for country information and instead the DEFAULT COUNTRY value is reported to all computers that request country information. In DISABLED mode no country information is supplied to computers requesting country information. LINDY CPU Switch Dual Multi-Platform Installation and Use Page 34 Keyboard Country Codes Country Code Country Code Arabic 01 Persian (Farsi) 20 Belgian 02 Poland 21 Canadian-Bilingual 03 Portugese 22 Canadian-French 04 Russian 23 Czech Republic 05 Slovakian 24 Danish 06 Spanish 25 Finnish 07 Swedish 26 French 08 Swiss/French 27 German 09 Swiss/German 28 Greek 10 Switzerland 29 Hebrew 11 Taiwan 30 Hungary 12 Turkish-Q 31 International (ISO) 13 UK 32 Italian 14 US 33 Japan (Katakana) 15 Yugoslavia 34 Korean 16 Turkish-F 35 Latin American 17 Reserved 36-255 Netherlands 18 Not supported 00 Norwegian 19 3.6.8 MOUSE SWITCHING Accessed from menu: GLOBAL PREFERENCES Settings: ENABLED, DISABLED Like most LINDY KVM switches, the LINDY CPU Switch Dual MP's channel may be switched using a three button mouse or IntelliMouse (see section 4.9). Pressing the central button or wheel button together with the left hand mouse button will cause the LINDY CPU Switch to switch to the next available computer. When mouse switching is enabled the central mouse button or wheel mouse button is allocated to control the LINDY CPU Switch and is not therefore available for use by computer applications. If you want to use the central mouse button within your applications you will need to disable mouse switching. The rotation action of an IntelliMouse wheel is not affected and is always available to the computer application. 3.6.9 SCREEN SAVER Accessed from menu: GLOBAL PREFERENCES Settings: DISABLED; 2, 5, 7, 10, 15, 20 & 30 MINUTES LINDY CPU Switch Dual Multi-Platform Installation and Use Page 35 To avoid burning out the phosphor on CRT monitor screens, the LINDY CPU Switch can be set to blank the screen after no keyboard or mouse activity has been detected for a selected timeout period. If preferred, the user can blank the screen manually by selecting channel '0' using the keyboard hotkeys or by pressing ESC from the login screen. 3.6.10 AUTOSCAN MODE Accessed from menu: GLOBAL PREFERENCES Settings: SCAN LIST, ACTIVE PCs, ALL PCs The LINDY CPU Switch supports an autoscan mode that automatically scans between the connected computers in sequence. The LINDY CPU Switch supports three autoscan modes. In the first mode the LINDY CPU Switch will scan all the named computers that are defined in the autoscan list (SCAN LIST). The computers defined in the scan list may be connected to cascaded LINDY CPU Switches. If you wish to scan the ports on the current LINDY CPU Switch then you may select ALL the available computers or just the available computers that are currently powered on (the ACTIVE computers). Scanning just the active computers avoids blank screens from being displayed and stops the monitor from going into a power down state on every scan cycle. WARNING - Many modern monitors are fitted with automatic power save relays and will switch off after a few seconds if connected to an inactive PC. If you are using such a monitor you must not set the LINDY CPU Switch to scan ALL ports. Constant switching on and off of your monitor's relay will eventually damage your monitor. If you are using the SCAN LIST option then you should ensure that all the computers are active if you are using one of these monitors. If you choose to use the SCAN LIST option then you may define the computers to be scanned in the following manner. To define the autoscan list Ensure that you are logged on as the ADMIN user. From the main on-screen menu press F1 for MORE MENUS. Select EDIT AUTOSCAN LIST from the menu. A list of defined computers will appear. The starred computers will be autoscanned during the autoscan cycle. To add a computer to the autoscan list, move the selection bar over the computer name and press SPACE BAR. To add all named computers press F1. To remove LINDY CPU Switch Dual Multi-Platform Installation and Use Page 36 all named computers press F2. When all the computers that you wish to scan have a star to the right hand side of their name, press RETURN or ENTER to save the selections. The selected computers will be autoscanned in alphabetical order when you activate autoscan mode (when the SCAN LIST option is selected). 3.6.11 AUTOSCAN PERIOD Accessed from menu: GLOBAL PREFERENCES Settings: DISABLED; 2, 5, 7, 10, 15, 20, 30 SECONDS The autoscan time defines the length of ti...

Questo manuale è adatto anche per i modelli :
Accessori computer - 32353 (5.94 mb)
Accessori computer - 32353 (5.94 mb)
Accessori computer - 32353 (5.94 mb)
Accessori computer - 32354 (5.94 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie