|
Facilità d'uso
Performing these tasks ensures that Windows numbers the boot drives in the proper sequence. Adding Peripherals Required for PowerEdge 8450 Cluster Nodes WARNING: Hardware installation should be performed only by trained service technicians. Before working inside the computer system, see the safety instructions in your PowerEdge system documentation to avoid a situation that could cause serious injury or death. The following list provides PCI slot assignment information for the system’s PCI buses, RAID controllers, NICs, and DRAC 2. • PCI buses — PCI bus 1: PCI slots 1 and 2 are 64-bit, 33-MHz — PCI bus 2: PCI slots 3 through 6 are 64-bit, 33-MHz — PCI bus 3: PCI slots 7 and 8 are 64-bit, 33/66-MHz — PCI bus 4: PCI slots 9 through 10 are 64-bit, 33/66-MHz support.dell.com Dell PowerEdge Cluster SE100, SE200, and SL200 Platform Guide • RAID controllers — Install the RAID controller for the server’s internal drives in PCI slot 1. — Install additional RAID controllers in any available 64-bit, 33-MHz or 32-bit, 33-MHz PCI slot. — If you use multiple RAID controllers and there are available slots, Dell recommends installing the RAID controllers on separate 64-bit PCI buses to balance the load on the system. NOTICE: The PERC 2/DC is keyed to prevent installation in a 64-bit 33/ 66 MHz PCI slot. NOTE: The PERC 2/DC comes fitted with an ISA retainer (the extension bracket at the edge of the PCI card) to allow it to fit into a full-length ISA expansion slot. You may need to remove the ISA retainer from systems that use full-length PCI expansion slots. To remove the ISA retainer, use a Phillips screwdriver to remove the two screws that fasten the retainer to the PERC 2/DC. • NICs — NICs can be installed in any available PCI slot. • DRAC 2 — If you are currently using a DRAC 2 or plan to use one in the future, install it in PCI slot 2. NOTE: To make sure that the SCSI or RAID controller attached to the boot drives initializes first, you may have to change the scan order of the PCI bus, if the system BIOS supports this option, or change the order of the RAID, NIC, and DRAC 2. Performing these tasks ensures that Windows numbers the boot drives in the proper sequence. Adding Peripherals Required for PowerEdge 2300, 43xx, and 63xx Cluster Nodes There are no PCI slot requirements or restrictions. PowerEdge Cluster SE100, SE200, and SL200 Configuration Matrixes The following forms can be attached to the back of each cluster node or rack and may be used by the system installer to record important information about the hardware on each cluster component. In addition, have a copy of the form available any time you call Dell for technical support. Record the following information on the configuration matrix form: • Cluster name, installer, date installed, and notes • Cluster server information 10 Dell PowerEdge Cluster SE100, SE200, and SL200 Platform Guide • Storage array description for each storage array • Service tag information for each cluster component • Connectivity information to indicate the SCSI connector (A or B) on each shared storage system that connects to the RAID controller channel (A or B) on each shared storage system; see the PowerEdge Cluster Configuration Matrix for specific instructions • Each cluster node’s PCI slot number, a description of each slot, the adapters installed in each slot, and a usage description for each adapter installed support.dell.com Dell PowerEdge Cluster SE100, SE200, and SL200 Platform Guide 11 PowerEdge Cluster SE100 Configuration Matrix Cluster Type PowerEdge Cluster SE100 Cluster Name Installer Date Installed Applications Location Notes Node PowerEdge Server Model Windows NT Name Node 1 Node 2 Storage Array Description (Drive letters, RAID types, applications/data installed) Storage 1 Storage 2 Component: Node 1 Node 2 Storage 1 1 Storage 2 2 Service Tag System Storage 1 Storage 2 Node 1, controller 1 Node 2, controller 1 Node 1, controller 2 Node 2, controller 2 PCI Slot Number PCI Slot Description Adapter Installed (PERC 2/SC, NIC, and so on) Usage (Public Network, Private Network, Shared Storage, Internal Drives) PCI slot 1 PCI slot 2 PCI slot 3 PCI slot 4 PCI slot 5 PCI slot 6 PCI slot 7 12 Dell PowerEdge Cluster SE100, SE200, and SL200 Platform Guide PowerEdge Cluster SE200/SL200 Configuration Matrix Cluster Type PowerEdge Cluster SE200 or SL200 Cluster Name Installer Date Installed Applications Location Notes Node PowerEdge Server Model Windows NT Name Node 1 Node 2 Storage Array Description (Drive letters, RAID types, applications/data installed) Storage 1 Storage 2 Storage 3 Storage 4 Component: Node 1 Node 2 Storage 1 Storage 2 Storage 3 Storage 4 Service Tag System Storage 1 Storage 2 Storage 3 Storage 4 Node 1, controller 1 Node 2, controller 1 Node 1, controller 2 Node 2, controller 2 PCI Slot Number PCI Slot Description Adapter Installed (PERC 2/SC, PERC 2/DC, NIC, and so on) Usage (Public Network, Private Network, Shared Storage, Internal Drives) PCI slot 1 PCI slo...
Questo manuale è adatto anche per i modelli :Computer - POWEREDGE CLUSTER SE200 (77.96 kb)
Computer - POWEREDGE CLUSTER SL200 (77.96 kb)