|
da questo dispositivo ha anche altre istruzioni :
Facilità d'uso
ThinkServer TD100x features and specifications (Machine Types 4203,
4204, 4205, 4206)
The following information is a summary of the features and specifications of the
server. Depending on the server model, some features might not be available, or
some specifications might not apply.
Table 2. Features and specifications
Microprocessor:
Hot-swap fans:
Acoustical noise emissions:
v
Intel Xeon™ dual-core or quad-core with 12
v
Three (standard)
v
Sound power, idle: 5.5 bel declared
MB Level-2 cache
v
Upgradeable to six fans (for redundant
v
Sound power, operating: 6.0 bel declared
Important: Do not use dual-core and
cooling)
quad-core processors in the same server.
Environment:
Note: To upgrade to redundant cooling, install
v
Support for up to two microprocessors
v
Air temperature:
the redundant power and cooling option kit. Kit
v
Support for Intel Extended Memory 64
– Server on: 10° to 35°C (50.0° to 95.0°F);
Technology (EM64T)
includes one 835-watt hot-swap power-supply
altitude: 0 to 2134 m (7000 ft)
and three hot-swap fans.
– Server off: -40° to 60°C (-40.0° to 140.4°F);
Note: Use the Configuration/Setup Utility
maximum altitude: 2134 m (7000 ft)
program to determine the type and speed of the
Size:
v
Humidity:
v
microprocessors.
Tower
– Server on: 8% to 80%
– Height: 440 mm (17.3 in.)
– Server off: 8% to 80%
Memory:
– Depth: 747 mm (29.4 in.)
– Width: 218 mm (8.6 in.)
v
Minimum: 1 GB depending on server model,
Heat output:
expandable to 48 GB
– Weight: approximately 38 kg (84 lb) when
fully configured or 20 kg (42 lb) minimum
v
Type: 667 MHz, PC2-5300, ECC Fully
Approximate heat output in British thermal units
v
Buffered DIMMs (FBD) with double data rate
Rack
(Btu) per hour:
(DDR) II, SDRAM
– 5 U
v
Minimum configuration: 2013 Btu per hour (590
– Height: 218 mm (8.6 in.)
v
Connectors: Twelve 240-pin dual inline
watts)
memory module (DIMM) connectors
– Depth: 696 mm (27.4 in.)
v
Maximum configuration: 2951 Btu per hour (865
– Width: 424 mm (16.7 in.)
watts)
Drives:
– Weight: approximately 34 kg (75 lb) when
fully configured or 20 kg (42 lb) minimum
v
IDE:
Electrical input:
– DVD (standard)
v
Sine-wave input (50-60 Hz) required
– CD, CD-RW, DVD/CD-RW (optional)
Racks are marked in vertical increments of 4.45
v
Input voltage low range:
– Maximum of two devices can be installed
cm (1.75 inches). Each increment is referred to
– Minimum: 100 V ac
as a unit, or “U.” A 1-U-high device is 4.45 cm
v
Diskette (optional): External USB 1.44 MB
– Maximum: 127 V ac
(1.75 inches) tall.
v
Supported hard disk drives:
v
Input voltage high range:
– Serial Attached SCSI (SAS)
– Minimum: 200 V ac
– Serial Advanced Technology Attachment
Integrated functions:
– Maximum: 240 V ac
v
(SATA)
Baseboard management controller (Intelligent
v
Approximate input kilovolt-amperes (kVA):
Platform Management Interface (IPMI) 2.0
– Minimum: 0.60 kVA
Expansion bays:
compliant)
– Maximum: 0.88 kVA
v
Service microprocessor support for Remote
v
Eight hot-swap SAS, 3.5-inch bays or 12
hot-swap SAS, 2.5-inch bays
Supervisor Adapter II SlimLine
Notes:
v
Light path diagnostics
v
Three half-high 5.25-inch bays (DVD drive
1. Power consumption and heat output vary
v
installed)
ServeRAID-8k (512 MB with battery backup)
depending on the number and type of optional
Note: Full-high devices such as an optional
and ServeRAID-8s SAS Controllers support
features that are installed and the
tape drive will occupy two half-high
RAID levels 0, 1, 1E, ,10, 5, 6, 50, and 60
power-management optional features that are
5.25-inch bays.
Note: The server will not start without a
in use.
RAID controller installed.
2. These levels were measured in controlled
PCI and PCI-X expansion slots:
– Eight 3.5–inch hard disk drive models:
ServeRAID-8k-l or ServeRAID-8k
acoustical environments according to the
v
Six PCI expansion slots
procedures that are specified by the American
– Three PCI Express x8 (two x8 links and
– Twelve 2.5-inch hard disk drive models:
National Standards Institute (ANSI) S12.10 and
one x4 link) slots
ServeRAID-8k and ServeRAID-8s
ISO 7779 and are reported in accordance with
v
– One PCI 33 MHz/32-bit slot
Four Universal Serial Bus (USB) ports (2.0)
ISO 9296. Actual sound-pressure levels in a
– Two PCI-X 2.0 133 MHz/64-bit slots
– Two on rear of server
– Two on front of server
given location might exceed the average stated
values because of room reflections and other
v
Upgradeable microcode:
Broadcom 5721 and 5721KFB3 10/100/1000
nearby noise sources. The declared
System BIOS, service microprocessor, BMC, and
Gigabit Ethernet controllers
sound-power levels indicate an upper limit,
v
SAS microcode
ATI PCI ES1000 video
– 16 MB video memory
below which a large number of computers will
operate.
Power supply:
– VGA and SVGA compatible
v
Note: To upgrade to two 835-watt hot-swap
ATA-100 single-channel IDE controller (bus
power supplies, install the redundant power and
mastering)
v
cooling option kit. Kit includes one 835-watt
Vitesse VSC7250 SAS/SATA RAID controller
v
power-supply and three hot-swap fans.
Mouse connector
v
Keyboard connector
v
Standard: One 835-watt 110 V or 240 V ac
v
input dual-rated power supply
Serial connector
v
Upgradeable to two 835-watt hot-swap power
supplies
Chapter 1. Introduction
5
... Questo manuale è adatto anche per i modelli :
Computer - ThinkServer TD100x (8.48 mb)