Facilità d'uso


Event ID
Event Severity Event Description
The system software violated one of the 'well-behavedness' rules of soft partitions
and tried to call a firmware procedure within the firmware instance of a sibling. This
is an access violation and firmware rejects the call. Probable Cause: System Software
Defect - using the wrong entry address for the owner of the CPU. Recommended
Action: Update the system software WBEM EventID: 4928. WBEM ProviderName:
11515
Warning
FPL_IndicationProvider
AlbInitPrep was unable to read the ALREC_CONFIG CSR to determine whether the
link is up or not. Data field: unused. Probable Cause: An error occurred while routing
the fabric Recommended Action: Collect IPMI event logs, and contact your HP support
representative to inspect the fabric and system firmware. WBEM EventID: 4929.
11521
Warning
WBEM ProviderName: FPL_IndicationProvider
The fPar whose ID is identified in the event detail is disabled from booting because
it has no bootable, healthy CPU. It may not own any CPU or the CPUs it owns are
Unhealthy (or deconfigured). Probable Cause: The fPar whose ID is identified in the
event detail is disabled from booting because it has no bootable, healthy CPU. It may
not own any CPU or the CPUs it owns are Unhealthy (or deconfigured) Recommended
Action: Use the soft partitioning configuration tool released with the OS product to
reconfigure the fPar and reboot the partition. A cold reset of the hard partition may
11529
Warning
be required WBEM EventID: 4930. WBEM ProviderName: FPL_IndicationProvider
Non-critical event announces that an fPar is enabled to boot but has inadequate
memory resources to instantiate the firmware for the fPar. The configuration is
modified to disable but not delete this fPar. Probable Cause: The user has configured
an fPar to be booted with inadequate memory resources to instantiate the firmware
image for this fPar. The fPar is software deconfigured (disabled) from booting.
Recommended Action: Reconfigure the fPar, giving it at least instance-size (an fPars
EFI variable) amount of physically contiguous RAM. Then re-enable and reset the
11530
Warning
fPar. WBEM EventID: 4931. WBEM ProviderName: FPL_IndicationProvider
The fPar has been enabled to boot, and contains at least one CPU and adequate
memory but has not been given any IO resources. It must be reconfigured and reset
before it may boot an operating system. Probable Cause: The fPar has been enabled
to boot, and contains at least one CPU and adequate memory but has not been given
any IO resources. The soft partition (fPar) may therefore only boot as far as the EFI
shell. It must be reconfigured and reset before it may boot an operating system.
Recommended Action: Reconfigure the soft partition using an
Operating-system-specific utility then reset the soft partition. WBEM EventID: 4932.
11531
Warning
WBEM ProviderName: FPL_IndicationProvider
All processors are scheduled for deconfiguration. Probable Cause: All CPUs were
scheduled to be deconfigured through a combination of user deconfigures and/or
failures Recommended Action: No action is required. WBEM EventID: 5270. WBEM
11537
Warning
ProviderName: FPL_IndicationProvider
Processors have been reconfigured due to installation of a new processor type, or
SFW revision change. Probable Cause: Either all CPUs were slated for deconfiguration,
or NVM has been cleared, or a new CPU type has been installed. Recommended
Action: No action is required. WBEM EventID: 5262. WBEM ProviderName:
11538
Warning
FPL_IndicationProvider
IO Backplane 3.3V power fault. Probable Cause: One of the 3.3v VRM's is reporting
a fault, one failure and power state is N, after two power state will be N-.
Recommended Action: Check IO backplane power board faulted VRM is give by PS
11566
Error
command. WBEM EventID: 6825. WBEM ProviderName: FPL_IndicationProvider
IO Backplane 5.0V power fault. Probable Cause: One of the 5.0v VRM's is reporting
a fault, one failure and power state is N, after two power state will be N-.
Recommended Action: check IO backplane power board faulted VRM is give by PS
11567
Error
command. WBEM EventID: 6826. WBEM ProviderName: FPL_IndicationProvider
IO Backplane -12V power fault. Probable Cause: One of the -12v VRM's is reporting
a fault, one failure and power state is N, after two power state will be N-.
Recommended Action: Check IO backplane power board faulted VRM is give by PS
11568
Error
command. WBEM EventID: 6827. WBEM ProviderName: FPL_IndicationProvider
88
WBEM Provider Event Tables


...

Questo manuale è adatto anche per i modelli :
Computer - HP Integrity rx7620 Server (973.52 kb)
Computer - HP Integrity rx8620 Server (973.52 kb)
Computer - HP Integrity NonStop BladeSystem NB50000c Server (973.52 kb)
Computer - HP Integrity rx7640 Server (973.52 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie