Log:
valutazioni - 3, GPA: 4 ( )

Istruzioni per l'uso Fujitsu, Modello PRIMERGY RX600 S6

Produttore : Fujitsu
File Size : 2.2 mb
File Nome : rx600s6-om-en.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


. The unit automatically adjusts itself to a mains voltage in a range of 100 - 127 V / 200 - 240 V. Ensure that the local mains voltage lies within these limits. . This device must only be connected to properly grounded power outlets or insulated sockets of the rack's internal power supply with tested and approved power cords. . Ensure that the device is connected to a properly grounded power outlet close to the device. 28 Operating Manual RX600 S6 Important information V CAUTION! . Ensure that the power sockets on the device and the properly grounded power outlets are freely accessible. . The On/Off button or the main power switch (if present) does not isolate the device from the mains power supply. To disconnect it completely from the mains power supply, unplug all network power plugs from the properly grounded power outlets. . Always connect the server and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the server is still running but a peripheral device (e.g. memory subsystem) fails during a power outage. . Data cables must be adequately shielded. . Ethernet cabling has to comply with EN 50173 and EN 50174-1/2 standards or ISO/IEC 11801 standard respectively. The minimum requirement is a Category 5 shielded cable for 10/100 Ethernet, or a Category 5e cable for Gigabit Ethernet. . Route the cables in such a way that they do not create a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting the server, refer to the relevant instructions in this manual. . Never connect or disconnect data transmission lines during a storm (risk of lightning hazard). . Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can get inside the server (risk of electric shock, short circuit). . In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign bodies), switch off the server immediately, remove all power plugs and contact your sales outlet or customer service team. RX600 S6 Operating Manual Important information V CAUTION! . Proper operation of the system (in accordance with IEC 60950-1/2 resp. EN 60950-1/2) is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted (electric shock, cooling, fire protection, interference suppression). . Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals. If you install other expansions, they may damage the system or violate the safety regulations. Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet. . The components marked with a warning notice (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. Exception: CSS components can be replaced. . The warranty is void if the server is damaged during installation or replacement of system expansions. . Only set screen resolutions and refresh rates that are specified in the operating manual for the monitor. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service center. . Before installing/removing internal options to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the outlet. Failure to do so can cause electric shock. . Do not damage or modify internal cables or devices. Doing so may cause a device failure, fire, or electric shock. . Devices inside the server remain hot after shutdown. Wait for a while after shutdown before installing or removing internal options. . The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Before handling them, first touch a metal part of the server to discharge static electricity from your body. . Do not touch the circuitry on boards or soldered parts. Hold the metallic areas or the edges of the circuit boards. 30 Operating Manual RX600 S6 Important information V CAUTION! . Install the screw removed during installation/detaching Internal Options in former device/position. To use a screw of the different kind causes a breakdown of equipment. . The installation indicated on this note is sometimes changed to the kind of possible options without notice. Batteries V CAUTION! . Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system board). . Do not throw batteries into the trash can. . Batteries must be disposed of in accordance with local regulations concerning special waste. . Replace the lithium battery on the system board in accordance with the instructions in the technical manual for the system board. . A...

Questo manuale è adatto anche per i modelli :
Computer - PRIMERGY RX600 S6 (2.2 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie