Log:
valutazioni - 4, GPA: 4.3 ( )

Istruzioni per l'uso Fujitsu, Modello C120-E361-04EN

Produttore : Fujitsu
File Size : 701.08 kb
File Nome : 9a40a6e5-8830-494f-b4d3-03de45f24a53.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


You can use this command if the system is powered off. setrci -c set [host_no] Sets up an RCI Host node. Before this command can be executed, the RCI settings must already have been initialized. host_noAF Integer numbers from 1 to 32 are assigned in this order. setrci -c initconfig Assigns an RCI address to an I/O unit connected via RCI. Before this command can be executed, the RCI Host node settings must already have been made. setrci -c addconfig Makes the RCI settings for the case that a host unit or an I/O unit is added. C120-E361-04EN CHAPTER 1 RCI Build Procedure 1.3 RCI Setup This section explains the RCI setup for the following cases: • New setup for a single RCI Host and two RCI I/O units • New setup of two RCI Hosts • When an RCI I/O unit is added later • When a RCI Host is added later Remarks: Please refer to Appendix A, "Troubleshooting." when there is a problem at RCI setup. 1.3.1 New setup for a single RCI Host and two RCI I/O units RCI Host RCI I/O unit RCI I/O unit Figure 1.5 New setup for a single RCI Host and two RCI I/O units 1 Log in to the XSCF Shell. 2 Execute the setrci -c stat command to display the RCI status. XSCF> setrci -c stat HOST address 000f7fff Inactive The command completed successfully 3 Verify that the RCI address is 000f7fff. Remarks: 000f7fff is the default value of the RCI address. If the default value is not set, execute the setrci -c init command to initialize the value. If the system is powered off, you can use the setrci -c init command. C120-E361-04EN 1.3 RCI Setup XSCF> setrci -c init The command completed successfully 4 Connect the main unit and I/O units with RCI cables (see Figure 1.5). Connect an RCI branching connector to each of the RCI ports, and connect them with RCI cables by using a daisy-chain connection. Connect an RCI terminating resistor to the branching connector at either end of the RCI connection. Refer to Section 1.3.5, "Connection of RCI." 5 Turn on the AC input to all the RCI device which are in the RCI connection. 6 Execute the setrci -c set command to make the settings of the host node. Since the main unit is the first unit, host_no is 1. XSCF> setrci -c set 1 The command completed successfully 7 Execute the setrci -c initconfig command to configure the RCI. XSCF> setrci -c initconfig The command completed successfully 8 Execute the setrci -c stat command to display the RCI status. XSCF> setrci -c stat HOST address 000101ff Active LIST address pwr alm I/F sys-phase ctgry dev-cls sub-cls tm-out 000101ff OFF -ACT power-off host 0001 0b - 003001ff OFF -ACT power-off disk 0400 04 - 003002ff OFF -ACT power-off disk 0400 04 The command completed successfully 9 Verify that all the RCI device in the RCI connection are incorporated. C120-E361-04EN CHAPTER 1 RCI Build Procedure 1.3.2 New setup of two RCI Hosts RCI RCI Host A Host B RCI I/O unit RCI I/O unit Figure 1.6 New setup of two RCI Hosts 1 Log in to the XSCF Shell. 2 On main unit A, execute the setrci -c stat command to display the RCI status. XSCF> setrci -c stat HOST address 000f7fff Inactive The command completed successfully 3 Verify that the RCI address is 000f7fff. Remarks: 000f7fff is the default value of the RCI address. If the default value is not set, execute the setrci -c init command to initialize the value. If the system is powered off, you can use the setrci -c init command. XSCF> setrci -c init The command completed successfully 4 In a similar manner, display the RCI status of main unit B to verify that the RCI address is 000f7fff. 5 Connect the main unit and I/O units with RCI cables (see Figure 1.6). Connect an RCI branching connector to each of the RCI ports, and connect them with RCI cables by using a daisy-chain connection. Connect an RCI terminating resistor to the branching connector at either end of the RCI connection. Refer to Section 1.3.5, "Connection of RCI." 6 Turn on the AC input to all the RCI device which are in the RCI connection. C120-E361-04EN 1.3 RCI Setup 7 On main unit A, execute the setrci -c set command to make the settings of the host node. Since main unit A is the first unit, host_no is 1. XSCF> setrci -c set 1 The command completed successfully 8 On main unit B, execute the setrci -c set command to make the settings of the host node. Since main unit B is the second unit, host_no is 2. XSCF> setrci -c set 2 The command completed successfully 9 On main unit A, execute the setrci -c initconfig command to configure the RCI. XSCF> setrci -c initconfig The command completed successfully 10 Execute the setrci -c addconfigcommand on main unit B to expand the RCI configuration. XSCF> setrci -c addconfig The command completed successfully 11 Display the RCI status by executing the setrci -c stat command on main unit A. XSCF> setrci -c stat HOST address 000101ff Active LIST address pwr alm I/F sys-phase ctgry dev-cls sub-cls tm-out 000101ff OFF -ACT --host 0001 0b - 000102ff OFF -ACT --host 0001 0b - 003001ff OFF -ACT --disk 0400 04 003002ff OFF -ACT --disk 0400 0...

Questo manuale è adatto anche per i modelli :
Computer - C120-E361-04EN (701.08 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie