|
Facilità d'uso
This heater is designed for permanent installation only, care should be taken to install according to the following instructions. All required clearances should be maintained, in addition all electrical wiring and connections should comply with local electrical codes. Note : It is extremely important to read all information labels. Care must be taken to ensure that the heater is rated the same voltage as the electrical supply wires. Failure to do so could result in unsafe heater operation as well as damage to the unit. If replacing an existing heater, check the labels of the old heater to ensure the voltage of the new heater is compatible. All units should be controlled by means of a regulating thermostat,certain models only are provided with built in thermostats, check the Model Key Information section for verification. Wall thermostats should comply with the voltage and wattage of all heaters on the circuit. Built in thermostats are not suitable for Register Grille Models. All installations require the following components 1) Recess Mount Box ( Model 6100831000 ) 2) Heater Assembly ( See nameplate Label ) 3) Grille ( Either Multi- Directional Style or Register Style ) An optional Surface mount box is available for installations that are not recessed in wall cavity. STEP 1 – Placement All units are designed for placement in either interior or exterior walls. Care should be taken to provide a minimum of 8" clearance from floors, ceilings and adjacent walls. Once installed, the airflow through the heater should not be blocked in any way. Maintain 3ft clearance of objects from the front of unit. Maintain a spacing of 3ft between heaters in order to prevent re-circulation of heated air. Insulation surrounding the back and sides of the recess mount box will not affect performance. Ensure insulation is rated for temperatures up to 85oC. Note: Certain flooring and wall covering materials ( particularly those incorporating clear vinyl materials tend to distort at temperatures in the vicinity of 60 C ( 140 F ). Material shall be checked prior to installation to determine if discoloration will occur. Units are not approved for placement in floors or ceilings. Do not install in any area where combustible vapors, gases, dusts or liquids are present. Fire or explosion may occur. STEP 2 – Mounting The Recess Box Determine the desired orientation of unit. Provide an opening in wall 14 .” x 7 5/8" x 3 3/8" deep minimum. Care should be taken to install the recess box in the correct orientation to accommodate grille. Note the position of the electrical entry knockouts and orient recess box according to Figure # 1. Ensure all required clearances are met. Ensure recess box flanges are flush with the finished wall surface. For new construction, the sides of the recess box are marked with guidelines to allow for .” and 5/8 “ drywall thickness if drywall is to be added at a later date. Secure recess box to studs with screws using holes provided on sides or flange of recess box. Remove appropriate electrical knockout and secure supply wire using an approved strain relief connector leaving 6" of wire leads in the recess box. STEP 3 - Mounting the Heater Assembly Insert the heater assembly into the recess box ensuring that the tab on the heater assembly slides into the slot in the recess box. Ensure the heater assembly is fully seated and secure to the recess box using the captive screw provided. STEP 4 –Electrical Connections Route supply wires from circuit breaker through wall thermostat to heater. For models with built in thermostat route from circuit breaker to heater. Supply wire must be of two wire plus ground variety, with a rating capable of handling all heaters on the circuit. Supply wire should be rated for a minimum of 60C. Make electrical connection according to relevant diagrams shown on Figure # 2. Make connections using approved wire nut...
Questo manuale è adatto anche per i modelli :Condizionatori - 6100790000 (202.64 kb)