|
Facilità d'uso
Also keep curtains and blinds closed during the sunniest parts of the day while the air conditioner is in operation. • Frequently clean the portable air conditioner’s filters. • Once the room or area has reached your desired comfort level, be sure to reduce the unit’s temperature and ventilation settings. FIG. 1 FIG . 2 FIG. 4 1 K0080-1-2 PARTS LIST Front: Back: 1. Control panel 2. Louvers 3. Carrying handle 4. Casters 5. Air filters 6. Air inlets 7. Exhaust air outlet 8. Cord wrap 9. Rubber plug / drainage hole Accessories: 10. Hose adapter (goes over the exhaust hose and into the back of the unit) 11. Exhaust hose 12. Round connector (to be used in between the hose and window kit or through a wall) 13. Exhaust cap 14. Extendable window kit 15. Drain hose for continuous drainage 16. Activated carbon filter 17. Remote control 2 K0080-1-2 INSTALLATION INSTRUCTIONS Installing the Exhaust Hose and Window Kit: The unit is a portable air conditioner that may be moved from room to room. Hot air must be exhausted out of the room for the appliance to work. This can be done with the included window kit or by cutting a hole into a wall. 1. Venting Through a Window (Using the Window Kit) • Attach the round connector to the exhaust hose and secure it in place with screws. Then, insert the other end of the exhaust hose into the window kit’s round opening. • Open your window and insert the window kit into the open gap. Adjust the size of the kit if necessary by sliding the window across so that the window kit is securely held into place. This technique may also be used for sash windows. 2. Venting Through a Wall FIG.7 FIG.6 • Cut a 5.95” (151 mm) diameter hole in the wall. • Insert the exhaust hose through the hole. On the other side of the wall, attach the round connector to the exhaust hose with screws (Fig. 7). When the air conditioner is not in use, cover the hole with the provided exhaust cap. 3 K0080-1-2 Positioning the Exhaust Hose: • Slide the hose adaptor over the opening on the back of the unit. • Then insert one end of the exhaust hose into the adapter. • Avoid kinks and bends in the exhaust hose. This can cause moist air to accumulate, resulting in overheating and unexpected shut offs. • The exhaust hose may be extended from 12” (300 mm) to 59” (1500 mm), but for maximum efficiency, use the shortest hose length possible. FIG.8 FIG.9 FIG.10 WARNING! The included exhaust hose is specifically designed to fit the specifications of this unit. Do not extend it with your own hose, as this can cause the air conditioner to malfunction. 4 K0080-1-2 Installing the Activated Carbon Filters: 1. Remove the filter frames from the unit (left and right sides). 2. Separate the filters from the filter frames. 3. Remove the activated carbon filters from their plastic bags. 4. Attach the activated carbon filters onto the filter frames. 5. Re-fix the filters to the filter frames (make sure the active carbon filters will be hold properly). 6. Re-install the filter frames to the unit. 2 3 5 FIG.12 5 K0080-1-2 OPERATING INSTRUCTIONS Control Panel: FIG.13 1. ON/OFF (power) button 12. Remote control receiver 2. Full water tank indicator 13. Timer display 3. Fan mode indicator 14. Temperature increase button 4. Mode selection button 1 5. Timer button 5. Heater indicator (AC-14000H only) 1 6. Ionizer indicator 6. Fahrenheit indicator 17. Ionizer button 7. Swing button 18. Fan speed indicator 8. Sleep mode indicator 19. Automatic mode indicator 9. Sleep mode button 20. Fan speed button 10. Temperature decrease button 21. Cooling mode indicator 11. Temperature display 6 K0080-1-2 Turning the Unit On and Off 1. Press the ON/OFF button. The unit will automatically begin operating. If the ambient temperature is higher than 74o F, the unit will work in cooling mode. If the temperature is at or below 74o F, the unit will work in ventilation (fan) mode. 2. At this time, the indicator lights will show any functions that are in progress. Please note that the display window will only show ambient room temperatures ranging from 32o F to 122° F. 3. To turn the unit off, press ON/OFF button again. Setting the Mode/Function: 1. Press the MODE button to select the desired mode (cooling, fan or heating). Heating mode is only available on the AC-14000H. 2. The selected mode’s indicator light will turn on. Setting the Temperature: 1. Press the “Up” or “Down” button to change the set temperature. 2. The display window will indicate the set temperature. If no temperature is set, the display will show the ambient room temperature. 3. Please note that the default temperature for cooling is 75 o F and 68 o F for heating. Setting the Fan/Ventilation Speed: 1. Press the SPEED button to select the desired fan speed (high, medium or low). The desired fan speed will show on the display screen. 2. If the unit is in AUTO mode, it will automatically choose the fan speed d...
Questo manuale è adatto anche per i modelli :Condizionatori - AC14000H (2.73 mb)