Log:
valutazioni - 6, GPA: 4.2 ( )

Istruzioni per l'uso Philips, Modello Comfort-Cire AMC 25

Produttore : Philips
File Size : 1.89 mb
File Nome : e0153209-0c0d-47b7-bf34-a9566863948a.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Safety considerations . Selection of location . Recommended height and length . Installation Method . Refrigerant piping & drainage . Electrical wiring OPERATING INSTRUCTIONS . Operating tips . Product description . Auxiliary control . Remote control operation . Operating instructions . Care and maintenance . Trouble shooting INSTALLATION INSTRUCTIONS TOOLS AND SUPPLIES The following tools are needed The following materials are for installation. required: 1. Level 1. Correct size copper tubing 2. Hole Saw 2. Correct size drain pipe 3. Core bits 3. Sleeve and bush 4. Hammer 4. Vinyl tape 5. Drill 6. Torque wrench 5. Saddle & Clamps to support 7. Adjustable wrench refrigerant piping 8. Flat head screwdriver 6. Power supply cable 9. Philips head screwdriver 7. Insulation material 10. Wire stripper 11. Measuring tape 8. Putty or similar sealant 12. Ratchet set 13. Flaring tools 14. Tube cutter SAFETY CONSIDERATIONS Installation and servicing of air conditioner can be hazardous due to high refrigerant pressure and electrical components inside the unit. Only fully trained, qualified and certified service personnel should install, repair and service the air conditioner. While working on the air conditioner, all precautions in the literature, tags and labels attached to the unit and all other general safety precautions should be carefully observed. Please follow all safety codes, wear safety glasses and work gloves. Also use quenching cloth for brazing operations. It is highly recommended that this manual be read completely before installing and operating the system. WARNING: The main power breakers to the unit , including its accessory or parts, should be turned off before performing service or maintenance operations on the unit. Dangerous high voltage can cause electric shock, serious personal injury or even death. SELECTION OF LOCATION Select a convenient location where: INDOOR UNIT . The cool air can reach every corner of the area to be cooled. . The unit is away from any direct heat source . Easy and short routing of the refrigerant and drain pipes to the exterior. . There are no flammable gas, alkaline or acid present in the air. . Air circulation is not obstructed, preventing good air circulation. . The structure where the unit is installed should be strong enough to support the weight of the unit and also prevent any vibration during operation of the unit. . Figure on the right shows the spacing to the nearest wall. OUTDOOR UNIT: . The condensing unit should be located as close as possible to the fan coil. . The air inlet shall be located at least 4” from the wall or other obstruction for unrestricted airflow. . The air outlet shall be located so as to direct discharged warm air away from the building. (Avoid low overhanging roofs to avoid re-circulation of condenser discharge air on vertical discharge models.) . Mount the unit on a sturdy base. . Figure on the right shows the spacing to be provided. RECOMMENDED HEIGHT AND LENGTH If the refrigerant piping is longer than the recommended length, or if the height difference between the indoor and outdoor unit is greater than recommended, the capacity will drop and the compressor could malfunction. Select an installation location that is within the recommended parameters. INSTALLATION METHOD HOLE DRILLING: After deciding the method your unit will be installed, a hole to route the connecting tubes and wires to the outdoor unit is to be drilled on the wall. The hole must be lower than the point where the drainpipe attaches to the drain pan of the unit. It should also be slightly declined towards the outside. (MAXIMUM PIPING LENGTH & HEIGHT RECOMMENDED) Piping length (feet) 23 50 Notes Cooling capacity 7,500 to 9,000 Btuh Add charge Not needed Needed (1) Installation not recommended Unit Piping Diameter 1/4" and 3/8” Recommended height difference is 23 ft or less *Evacuate refrigerant lines (1) An installation with a piping length of 23 ft. or less is desirable. If this is not possible, the maximum piping length can be extended to 50 ft. by charging the system with additional refrigerant. However, cooling and heating capacity will be reduced. • Additional charge volume = (piping length - 23 ft.) x 0.2 oz. Piping length (feet) 33 55 Notes Cooling capacity 18,500 t...

Questo manuale è adatto anche per i modelli :
Condizionatori - Comfort-Cire AMC 30 (1.89 mb)
Condizionatori - Comfort-Cire AMC 45 (1.89 mb)
Condizionatori - Comfort-Cire AMC 60 (1.89 mb)
Condizionatori - Comfort-Cire AMC Series (1.89 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie