|
Facilità d'uso
installing and using this appliance, Manual SWING TIMER ON/OFF MODE FAN SPEED F HR Window (Room) Air Conditioner User Manual RWC-3217 RWC-4717 CONTENTS Safety Precautions 2 Parts Name 3 Operating Instructions 5 Care and Maintenance 8 Operation Tips 9Trouble Shooting 10 11 Installation Instructions 1 SWING OFFON/MODE TIMER FAN SPEED F HRHR 2 Symbols in this User's Manual are interpreted as shown below: Be sure not to do. The feature of the appliance, instead of a fault. Pay attention to such a situation. Grounding is necessary. Be sure to follow the instruction. Do not use the power supply circuit breaker or pull off the plug to turn it off during operation. This may cause a fire due to spark, etc. Keep the power supply circuit breaker or plug from dirt. Connect the power supply cord to it firmly and correctly, lest an electric shock or a fire break out due to insufficient contact. Otherwise, serious faults maybe occur Use correct power supply according to the rating plate. or a fire maybe break out. Do not knit, pull or press the power supply cord, lest the power supply cord be broken. An electric shock or fire is probably caused by a broken power supply cord. Never insert a stick or similar to the unit. Since the fan rotates at high speed, this may cause an injury. Do not repair the appliance by yourself. If this is done incorrectly, it may cause an electric shock, etc. Turn off the appliance first before cutting off power supply when malfunction occurs. It is harmful to your health if the cool air reaches you for a long time. It is advisable to let the air flow be deflected to all the room. Prevent the air flow from reaching the gas burners and stove. Do not touch the operation buttons when your hands are wet. Pull off the plug to stop it when the operation is abnormal ( a peculiar odor is smelled, etc.), or it may cause an electric shock, etc. It is the user's responsibility to make the appliance be grounded according to local codes or ordinances by a licenced person. Warning: Incorrect handling could cause a serious hazard, such as death, serious injury,etc. SWING OFFON/ MODE TIMER FAN SPEED F HRHRSWING SWING OFFON/MODE TIMER FAN SPEED F HRHR SWING OFFON/MODE TIMER FAN SPEED F HRHR SWING OFFON/ MODE TIMER FAN SPEED F HRHR Safety Precautions A A E ® . i Note: The figure in this manual are based on the external view of a standard model. Consequently, the shape may differ from that of the a conditioner you have selected. Air Outlet Fig. 1 Control Panel Power Cord Interior Air Inlet Grille Horizontal Air Vane Vertical Air Vane Front view Fresh air lever Exterior Air Inlet Exterior Air Inlet Remote Controller SWING OFFON/ MODE TIMER FA NSPEED FFHRHR For remote control model 3 Parts Name AAE®.i Note: The figure in this manual are based on the external view of a standard model. Consequently, the shape may differ from that of the a conditioner you have selected. Air Outlet Fig. 1 Control Panel Power Cord Interior Air Inlet Grille Horizontal Air Vane Vertical Air Vane Front view Fresh air lever Exterior Air Inlet Exterior Air Inlet Remote Controller SWING OFFON/ MODE TIMER FA NSPEED FFHRHR For remote control model 3 Parts Name Air Filter handle Fresh air lever SWING OFFON/ MODE TIMER FAN SPEED F HRHR Shut the fresh air door to achieve the best cooling effect and open it to introduce fresh air into the room if the air is foul inside . Fresh air lever SHUT OPEN Fresh air lever Pull out Push in Fig.1 Fig.2 A A E ® . i Outside Air Outlet Drainage Tip Exterior Air Inlet 1B.aAcck cveiesws ories 4 Parts Name MODE button Each time MODE button is pressed, the operation mode is changed in sequence: COOLING FAN ONLY ENERGY SAVING COOLING NOTE: After setting the mode, allow 3 minutes before switching to another mode. NOTE: Temperature setting range is from 19 (66 ) to 31 (88 ). FAN SPEED button Used to select fan speed in sequence auto, low, medium and high. SWING button Used to select start or stop vertical air vanes swinging. TIMER button Used to set or cancel timer operation. When the unit is in operation, you can set OFF TIMER. When the unit is off, you can set ON TIMER. Timer setting range is 0 to 24 hours. If the OFF TIMER is set, the timer LED displays the remaining time to turn off the unit for only 12 seconds, then LED shifts to display set temperature. If the ON TIMER is set, the timer LED displays the remaining time to turn on the unit. If you want to cancel ON TIMER, press TIMER button again. Used to set room temperature in COOLING mode or used to set time in TIME R mode. If the two keys are pressed at the same time,the temperature LED display will alternate between and . ON/OFF buttonThe air conditioner will be started when it is energized or will be stopped when it is in operation, if you press this button. You can easily operate this air conditioner by pressingrelevant button on the control panel as well as theremote controller. Indication symbols of LED on control panel: High fan speed Medium fan speed Low f...
Questo manuale è adatto anche per i modelli :Condizionatori - RWC-4717 (2.75 mb)