|
Facilità d'uso
All electrical work must be done in accordance with local or national electrical code as applicable. For safety, this product must be grounded. If you are unfamiliar with methods of installing electrical wiring, secure the services of a qualified electrician. 2. When wiring, servicing or cleaning this unit, turn off power and lock out service panel. Failure to do so could allow others or thermostat to turn on power unexpectedly which may cause fatal electrical shock. 3. To avoid electrical shock: • Do not install unit in a tub or shower enclosure or any location where it may come in contact with water. • Never place a switch where it can be reached from a tub or shower. 4. Do not install this unit in an area where chemicals and other flammables are stored or used. Explosion and fire may result. CAUTION 1. This product may ONLY be installed in a wall. Do not mount in any other position. 2. Install heater at least 12" from floor or any adjacent vertical surface. 3. Do not locate heater behind a door, furniture, drapes, etc., where the air flow to the unit would be restricted. 4. Provide heater with an appropriately-rated electrical circuit to prevent tripped breakers or blown fuses. 5. Do not connect heater to dimmer switch or speed control. 6. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc., off power unit. 7. Please read specification label on product for further information and requirement. PLAN THE INSTALLATION This heater is intended to be used to supply supplemental heat from a wall location in new or existing construction. Choose a location where edge of heater will be at least 12" from the floor or any adjacent vertical surface. The heater can be operated using its built-in thermostat or a remote thermostat (Choose either the Model 86W Line-Voltage thermostat or use the Model 82 Transfomer/Relay with an appropriate low-voltage thermostat.). The Model 85NT Kit is available for surface- mount applications. Purchase these accessories separately. Plan to supply the heater with proper line voltage and appropriate power cable. NOTE: Power can be tapped from a nearby circuit depending on the heater wattage required and the amperage rating of the circuit. Heater can be converted to half-wattage to avoid overloading such circuits. MODEL VOLTS AMPS WATTS BTU/HR 9192NT 240 8.33/4.17 2000/1000 6827/3413 9194NT 240 12.50/6.25 3000/1500 10240/5120 9198NT 240 16.67/8.33 4000/2000 13653/6827 Bold ratings are factory wired. See “OPTIONAL WIRING CONVERSIONS” section for wattage conversion instructions. Refer to FIGURE 1 Follow these basic steps when installing this heater: 1) Nail housing to studs. 2) Connect power cable. 3) Fasten heater assembly and grille to housing. FIGURE 1 DRYWALL THERMAL OVERLOAD GRILLE BUILT-IN THERMOSTAT HEATER HOUSING POWER CABLE 1 INSTALL THE HEATER Refer to FIGURE 2 1. Remove heater assembly from housing. Take out the four (4) screws shown and set heater assembly aside. Refer to FIGURE 3 2. Attach housing to wall studs. NOTE: Locate housing at least 12" from floor on any adjacent walls. Use the measuring guides on the sides of housing to position housing so that it will be flush with finished wall. Nail the housing to studs through the hole and slot on both sides of housing. NOTE: In 24"-on-center stud construction, framing in between studs is necessary. WIRE THE HEATER Refer to FIGURE 4 1. Connect power cable to housing. Attach electrical power cable to housing using appropriate connector. Allow 6" of wire inside housing. Secure ground wire to housing with grounding clip, as shown. Refer to FIGURE 5 and FIGURE 6 2. Wire the heater assembly. Connect wires from heater assembly to power cable wires. Follow wiring diagram. If heater is wired direct, use the built-in thermostat for temperature control. OPTIONAL WIRING CONVERSIONS When using a separate wall control, simply turn the heater's built- in thermost...
Questo manuale è adatto anche per i modelli :Condizionatori - 9198NT (127.67 kb)
Condizionatori - 9194NT (127.67 kb)