Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso GE Monogram, Modello 2900 Series

Produttore : GE Monogram
File Size : 1.94 mb
File Nome : zoneline_data_manual_08.pdf

Lingua di insegnamento: en

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


Enhanced Dehumidification Moisture removal is an important function of an air conditioner. People are more comfortable at higher temperatures when the humidity level is relatively low. Air conditioners operate with less energy consumption when the room temperatures are set higher. The GE Zoneline® 2900 Series with the Dry Air 25 heat pipe application removes 25% more moisture than the base 2900 Series unit. The GE Zoneline Dry Air 25 chassis is the only PTAC available with the application of the patented Dinh® Dehumidifier Heat Pipe under license from Heat Pipe Technology, Inc. Customers who are using the Dry Air 25 report a fresher- smelling room as a result of the lower humidity levels, as well as lower operating costs. Locking Door Kit RAK8023 — A door with a lock that replaces the standard control cover door to prevent unauthorized changing of control setting is offered as an accessory. Auxiliary Control Switches These switches are located behind the room cabinet under the control panel. 2900 and 3900 Series Switches Description Left Switches (1) ALL I2R Heat pump override — Down — Normal heat pump operation Up — resistance heat only ( 900 Series only) (2) C: FAN Fan control for cooling operation — Down — Fan Continuous Up — Fan Cycle ( ) H: FAN Fan control for heating operation — Down — Fan Cycle Up — Fan Continuous (4) CLASS 2 Remote Thermostat Mode — Down — Unit Control Up — Remote Thermostat (5) LOAD SHED Load Shedding when connected to Central Desk Control System — Down — Fan shuts off with unit Up — Fan under “Smart Fan” settings (6) FREEZ S Freeze Sentinel™ Override — Down — Freeze Sentinel ON Up — Freeze Sentinel OFF (7) CONST FAN Constant Fan — Down — Fan runs normally Up — Fan runs when unit is in STOP position Right Switches TL1 – TL Cooling temperature limiting (See table at bottom of page) TL4 – TL6 Heating temperature limiting (See table at bottom of page) (7) Heat Sentinel switch — Down — Heat Sentinel OFF Up — Heat Sentinel ON (8) Heat Boost ( 900 series only) — Down — Heat Boost OFF Up — Heat Boost ON Auxiliary (2900 and 900 series) 900 Series shown ALLI2R (All Electric Heat) (3900 Series models only) C: FAN CN (Cooling–Smart Fan) H: FAN CY (Heating–Smart Fan) CLASS 2 (Remote Thermostat) LOAD SHEDDING (CDC) FREEZ Sen (Freeze Sentinel) CONST FAN (Constant ON Fan) NO FUNCTION (Reserved for future use) 1 2 3 4 5 6 1 2 3 4 5 67 8 UP DOWN 7 8 UP DOWN HEAT BOOST (3900 Series models only) Heat Sentinel TL1 (H) (Temp. Limit 1–Heat) TL2 (H) (Temp. Limit 2–Heat) TL3 (H) (Temp. Limit 3–Heat) TL1 (C) (Temp. Limit 1–Cool) TL2 (C) (Temp. Limit 2–Cool) TL3 (C) (Temp. Limit 3–Cool) Cooling and Heating temperature limits are set independently, temperature limiting switches are in factory-set down position, except as noted. Cooling Temperature Limits Switches Up NONE 1 1, 2 2 2, 1, 2, 1, 60 64 66 68 70 72 74 76 Heating Temperature Limits Switches Up 6 4, 6 4, 5, 6 5, 6 5 4, 5 4 NONE 65 70 72 74 76 78 80 85 ge.com Auxiliary Control Switches These switches are located behind the room cabinet under the control panel. 5800 Series Switches Description Left Switches (1) ALL I2R Heat pump override — Down — Normal heat pump operation Up — resistance heat only (2) C: FAN Fan control for cooling operation — Down — Fan Continuous Up — Fan Cycle ( ) H: FAN Fan control for heating operation — Down — Fan Cycle Up — Fan Continuous (4) CLASS 2 Remote Thermostat Mode — Down — Unit Control Up — Remote Thermostat (5) LOAD SHED Load Shedding when connected to Central Desk Control System — Down — Fan shuts off with unit Up — fan under “Smart Fan” settings (6) FREEZ S Freeze Sentinel Override — Down — Freeze Sentinel ON Up — Freeze Sentinel OFF (7) CONST FAN Constant Fan — Down — Fan runs normally Up — fan runs when unit is in STOP position (8) OCCUPIED Occupancy Sensor Mode — Down — Unit Control Up — Occupancy Sensor Connected Right Switches TL1 – TL Cooling temperature limiting (See table at bottom of page) TL4 – TL6 Heating temperature limiting (See table at bottom of page) (7) Diagnostics Switch (8) Heat Sentinel switch — Down — Heat Sentinel OFF Up — Heat Sentinel ON (9) Heat Boost — Down — Heat Boost OFF Up — Heat Boost ON 5800 Series shown ALLI2R (All Electric Heat) C: FAN CN (Cooling–Smart Fan) H: FAN CY (Heating–Smart Fan) CLASS 2 (Remote Thermostat) LOAD SHEDDING (CDC) FREEZ Sen (Freeze Sentinel) CONST FAN (Constant ON Fan) OCCUPIED (Occupancy Sensor) Cooling and Heating temperature limits are set independently, temperature limiting switches are in factory-set down position, except as noted. Cooling Temperature Limits 1 2 3 4 5 6 1 2 3 4 5 67 8 UP DOWN UP DOWN TL1 (H) (Temp. Limit 1–Heat) TL2 (H) (Temp. Limit 2–Heat) TL3 (H) (Temp. Limit 3–Heat) TL1 (C) (Temp. Limit 1–Cool) TL2 (C) (Temp. Limit 2–Cool) TL3 (C) (Temp. Limit 3–Cool) 7 8 9 Diagnostics Switch HEAT BOOST Heat Sentinel Switches Up NONE 1 1, 2 2 2, 1, 2, 1, 60 64 66 68 70 72 74 76 Heating Temperature Limits Switches Up 6 4, 6 4, 5, 6 5, 6 5 4, 5 4 NONE 65 ...

Questo manuale è adatto anche per i modelli :
Condizionatori - 5800 Series (1.94 mb)
Condizionatori - 3900 Series (1.94 mb)
Condizionatori - 2900 Series (1.94 mb)
Condizionatori - 3900 Series (1.94 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie