Log:
valutazioni - 1, GPA: 4 ( )

Istruzioni per l'uso Amcor, Modello 9KE-410

Produttore : Amcor
File Size : 681.04 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Press the -button again in order to cancel the sleep mode. The set temperature will increase 1°C after 1 hour and a further 1°C after 2 hours. • No FAN mode under SLEEP mode operation. Dehumidification If the unit will be used mainly as a dehumidifier just let the warm air return in the room. Continuous drainage (see separate chapter) is then necessary and more efficient. ION (ionizer) The ionizer releases negatives ions in the air. These clean the air in the room by precipitating particles to the floor and other surfaces. Press the ION button to activate the ION (ionizer) function. The ION icon will be displayed. Pressing the same button will turn off the ION function. Air outlet up, louvres opened Raising the louvres housing. Air outlet down, louvres closed 10 GB The unit responds to all signals that are sent by the remote control. There will be a beep sound from the unit after receiving the signal. The operation of the unit by remote control, is almost identical to the operation by the control panel. The only exception is the clock function. Instead of the -button for setting the actual time and for programming the timer, there are 3 push buttons on the remote control as follows: • - for setting the actual time. • TIMER ON - for programming the time when the unit is ON. • TIMER OFF - for programming the time when the unit is OFF. REMOTE CONTROL 00:00 24:00 11 GB This air conditioner is equipped with two filter sets: 1. A multi layer filter in the upper air inlet, to clean the circulated room air, which includes a. a screen filter, to remove dust particles. b. an active carbon filter, to remove odours. 2. A screen filter in the lower air inlet, to emove dust particles. NOTE! The active carbon filter is delivered in a plastic packaging. Don’t forget to install it. a. The screen filter in the upper and lower air outlet should be cleaned regularly by rinsing them under running water. b. The active carbon filter can be cleaned with a vacuum cleaner when dusty but has to be changed every 3 months. Filter installation • Slide out the filter frame from the unit. • Separate the filter fixer from the filter frame (see fig. 1). • Remove the active carbon filter (black) from its plastic bag. • Insert the active carbon filter into the filter frame (see fig. 2). • Fix the filter by reassembling the fixer into the filter frame (see fig. 3) NOTE! • Remove the active carbon filter before seasonal storage and install new filters at the beginning of the new season. The old filters can be disposed in the ‘Nonbiological garbage container’. • Replacement filter packages are available directly from Amcor. • To run the unit without active carbon filter does not do any harm to the air conditioner. In this case odours are not removed from the circulated air. • The screen filter must always be used. AIR FILTERS 1 Filter fixer 2 3 Filter fixer Filter frame 12 GB EMPTYING THE INTERNAL WATER CONTAINER Under high humidity conditions it may be necessary to empty the internal water container. When the internal water container is full the backlight on the LCD-display flashes. The unit will switch off automatically. To empty the water container do the following: • Switch off the unit and remove the plug from the wall socket. Do not move the unit. Doing this can result in water leakage, damaging your floor or carpet. • Place the water container on the floor underneath the permanent drainage point. • Remove the water stopper and rubber plug from the drain and let the water run out. The water container has to be emptied several times before all water will be drained (ca. 1.5 litres). • Replace the rubber plug and water stopper, put the plug into the wall socket, and switch the unit on. The warning signal should be off. NOTE! When the air conditioner is in use, under normal circumstances the condensed water will evaporate and then be discharged through the hot air outlet hose. • Switch off the unit and remove the plug from the mains. • Remove the water stopper and rubber plug. • Connect a drain tube (o 20 mm inner dimension) onto the water outlet and extend with extra water tube if needed. • Place the other end in a normal drain. Make sure that the tube is free from twists and bends. The tube must decline over its entire length. CONTINUOUS DRAINAGE 13 GB WARNING! First of all switch off the unit and remove the plug from the wall socket. Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol, detergents or other cleansing solutions. Clean the air filters regularly, see the “air filter” section. NOTE! Never use the air conditioner without the screen filters. CLEANING STORAGE • Empty the internal water container. • Clean the screen filter. • Remove the active carbon filter before end of season storage and install new filters at the beginning of the new season. • The old filters can be disposed of in the ‘Non-biological rubbish container’. Replacement filter packages are available from Amcor. • Put the unit in Fan Only ...

Questo manuale è adatto anche per i modelli :
Condizionatori - 15KE-410 (681.04 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie