Log:
valutazioni - 4, GPA: 4.3 ( )

Istruzioni per l'uso Amcor, Modello AMC 10KM-410

Produttore : Amcor
File Size : 1.09 mb
File Nome : ab0f1f5c-8efe-41da-a834-ba11df36ca35.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Warning: This appliance must be earthed. This appliance operates from a 3 pin 13 amp plug. The voltage rating is 230 volts and should be protected by a 13 amp fuse either in the plug or distribution board. The appliance is supplied with a moulded 13 amp 3 pin mains plug fitted with a 13 amp fuse. Should the fuse require replacement, it must be replaced with a fuse rated at 13 amp and approved to BS1362. The plug contains a removable fuse cover that must be refitted when the fuse is replaced. In the event of the fuse cover being lost or damaged, the plug must not be used until a replacement cover has been obtained. If the moulded mains plug is unsuitable for the socket outlet in your home or is removed for any other reason, then the fuse should be removed and the cut off plug disposed of safely to prevent the hazard of electric shock. There is a danger of electric shock if the cut off plug is inserted into any 13 amp socket outlet. ELECTRIC CONNECTION (see page 8 on how to wire a plug) 5 POSITIONING GB This unit is portable and can easily be moved from one room to another. In doing so keep this in mind: • The air conditioner must stand upright on an even surface. • Position not (near) bath, douche or other wet or damp area. • Keep for free air circulation at least 50 cm free from any obstacle or curtains. Installation • Put the exhaust hose into the round side of the exhaust hose adapter (13) (fig. 1). • Put the wall/window adapter (14) onto the exhaust hose (fig. 2). • Connect the hose with the rectangular end to the air conditioner (fig. 4). Using the foam. Place the foam with the hole (11), if needed together with the foam extension (10), in the window and close this as far as possible to refrain the warm air from reentering the room (fig. 5). Depending on how the window opens, horizontally (fig. 3a) or vertically (fig. 3b). Pass the hose through the opening in the foam (11). Permanent hole in glass or wall. Place the wall/window connector (14) in the hole with diameter 130 millimetre (fig. 6). Connect the hose with the rectangular end to the air conditioner (fig. 4). Use the cap (15) to close the opening when the air conditioner is not used. Important The flexible exhaust hose can be extended from 300 to 1500 mm for mounting. This length has been designed especially according to the specifications of the air conditioner. Do not use an extension or exchange for a different hose as that may lead to malfunctioning. The exhaust air must flow freely, any blockage can lead to overheating of the air conditioner. Take care to prevent any bow or bend in the exhaust hose. 1 13 16 2 14 16 4 5 6 15 3a 3b 6 ON/OFF and timer function Turn the control [1] to switch the unit on or off. When the unit is on, LED-1 is on. Timer function Use control [1] to set a working time between 1 and 8 hours. The unit switches off when the set time has run down. Mode selection and speed setting Select with control [2] the required operating mode cooling or fan mode. The corresponding LED (2 or 3) will lit. Select the larger symbol position for high or low fan speed, or low or strong cooling. Thermostat setting Turn control [3] to maintain the temperature level in combination with cooling. Notices: • The compressor has been set so that it starts functioning three minutes after the (re)start of the air conditioner. • The cooling will switch off when the room temperature is lower than the set one. Ventilation will however continue to work on the set level. When the room temperature rises above the selected value, the cooling will work again. Air flow Turn the roller to control the air flow direction of the vertical louvres. Move the air vent directly to adjust the air flow direction of the horizontal louvres. OPERATION GB 3 2 1 1 2 3 4 7 GB When the water container is full, the compressor and the ventilator stop functioning, LED [4] will lit. Switch off the unit and remove the plug from the mains. • Place the water tray flat on the floor under the drain. • Remove the drain knob. • Remove the rubber plug and fill the water tray then replace the plug to stop the water flow. Empty the tray and repeat this process until all water has been removed. • Replace the rubber plug and the drain knob, plug the unit in and switch on. The LED [4] should now be out. Rubber plug Water tray Drain control EMPTYING THE INTERNAL WATER CONTAINER Switch off the unit and remove the plug from the mains. • Remove the drain knob and the rubber plug. • Connect the correct water tube onto the water outlet. • Place the other end in a normal drain. • Make sure that the tube is free from twists and bends. The tube must incline over its entire length. Dehumidification If the unit will be used mainly as dehumidifier, do not connect the exhaust hose and let the warm air return in the room. Continuous drainage is then convenient and more efficient. PERMANENT DRAINAGE 8 Important: how to wire a 13 amp plug The wires in the mains lead on this appliance are coloured in accorda...

Questo manuale è adatto anche per i modelli :
Condizionatori - AMC 12KM-410 (1.09 mb)
Condizionatori - AMC 7KM-410 (1.09 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie