Log:
valutazioni - 3, GPA: 4.3 ( )

Istruzioni per l'uso Frigidaire, Modello 2020252A0373

Produttore : Frigidaire
File Size : 2.48 mb
File Nome : 2020252a0373en.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


The "Sleep" mode program can be cancelled at any time during operation by again pressing the "Sleep" button. COOLING MODE: In this mode the exhaust adaptor hose MUST be used. 1. Press the MODE button until the "Cool" indicator lights. 2. Press the " " Temp buttons for desired setting. 3. Press the FAN button for desired fan speed. HEATING MODE: In this mode you do not need to use the exhaust adaptor hose. (on some models) 1. Press the MODE button until the "Heat" indicator lights. 2. Press the " " Temp buttons for the desired heat setting. TIMER OPERATION: You can set both delay stop and delay start while unit is in ON position or OFF position. When unit is in ON position, first press TIMER button to go to delay stop setting, then “timer off” light will illuminate, tap or hold the UP arrow ( ) or the DOWN arrow ( ) to change delay stop timer at 0.5 hour increments up to 10 hours, then at 1 hour increments up to 24 hours. Then press the TIMER button to confirm the setting (the control will confirm the setting automatically after 5 seconds) and go to delay start setting. Use the same way as above to set the delay start timing. If you don’t need to set delay start, press the TIMER button again to exit. After 5 seconds, the control will automatically change the display back to previous temperature display. If you want to check remain timing, press the TIMER button. The delay start operation automatically selects mode, temperature and fan speed the same as last operation you set. When unit is in OFF position, press TIMER button will first go to delay start setting, then “timer on” light will illuminate, set the delay start and delay stop timing the same way as above. To cancel the timer setting, simply tap ( ) or ( ) button to change the timing to 0.0. AUTO MODE: Always have the exhaust hose attached in this mode. When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(inapplicable for cooling only models), or fan only operation depending on what temperature you have selected and the room temperature. The air conditioner will control room temperature automatically round the temperature point set by you. Under AUTO mode, you can not select the fan speed. NOTE The following instructions represent the Control Panel, the same instructions can be used for the Remote Control. Operating Instructions Operating Instructions 9 2009 Electrolux Home Products, Inc. All rights reserved. Operating Instructions (continued) DRAINAGE: REMOTE CONTROL STORAGE : During dehumidifying mode, remove the supplied rubber stopper from the hose connector. Screw a suitable length of hose onto this connector. Place the open end into a suitable drain, and make sure there are no kinks in the hose. (Fig.23) The door on side of the unit is for storing the remote, to open press it as shown in Fig. 24, to close simply push it back into position. Continuous drain hose Fig. 23 Fig. 24 Remove the drain plug SWING OPERATION: When you turn on the unit, the louver will swing and stop at a certain angle. You can press the SWING button to let the louver swing automatically. Press the SWING button again while you want the louver stop at desired angle. CHECK FILTER FEATURE: This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more efficient operation. The LED (light) which above the "Filter" button will illuminate after 250 hours of operation. To reset after cleaning the filter, press the "Filter" button and the light will go off. FAULT CODE: If the display reads "EA" , the room temperature sensor has failed. Contact your Authorized Frigidaire Service Center. If the display reads "ES" , the evaporator temperature sensor has failed. Contact your Authorized Frigidaire Service Center. If the display reads "E4" , the display panel communication has failed. Contact your Authorized Frigidaire Service Center. If the display reads "P1" , bottom tray is full. Carefully move the unit to a drain location, remove the bottom drain plug and let the water drain away. Restart the machine until the "P1" symbol disappears. If error repeats, call for service. Press here Operating Instructions 10 2009 Electrolux Home Products, Inc. All rights reserved. (continued) Operating Instructions, CARE & CLEANING ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with. Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards. The "Cool" circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping. The fan will continue to run during this time. The control will maintain the set temperature within 2 °F, between 62 °F and 86 °F (17 °C and 30 °C). There is a 2-Second delay for the compressor shutting down when selecting FAN ONLY/H...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie