Log:
valutazioni - 0, GPA: 4 ( )

Istruzioni per l'uso Frigidaire, Modello 309000854

Produttore : Frigidaire
File Size : 248.89 kb
File Nome : a4d0e5ad-177e-4591-8a17-58b0d503a1df.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Set the thermostat at the highest number for the coldest setting. Once the room has reached the desired temperature, adjust the thermostat to a number providing the most comfort. Higher numbers provide lower room temperatures. Lower numbers provide warmer room temperatures. Night Time Cooling When outside temperatures drop below 70°F (21°C) and the unit is cooling, frost may form on the coils and block airflow into the room. If this occurs, operate the air conditioner on the “HIGH FAN” setting to defrost the coil. If cooling while the outside temperature is low, set the thermostat to the middle position. Make sure the louvers are open. This will help prevent frost build-up. 5 Air Conditioner Features (continued) (4-WAY) Rotary Vent Control This Vent Control allows the air conditioner to either recirculate inside air (CLOSED) or exhaust air to the outside (OPEN). These selections can be used with any FAN selection. The CLOSED position is used when maximum cooling is desired. It may also be used for air recirculation without cooling when the air conditioner is set in any FAN position. The OPEN position removes stale air from the room and exhausts it to the outside. Fresh air is drawn in through normal passages in the home. 4-Way Louvers The 4-Way air directional louvers allow you to direct air flow up or down, left or right throughout the room as needed. 6 Care and Cleaning Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards. Air Filter Cleaning The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils. • Grasp the filter by the center and pull up and out. • Wash the filter using liquid dishwashing detergent and warm water. Rinse filter thoroughly. Gently shake excess water from the filter. Be sure filter is thoroughly dry before replacing. • Or, instead of washing you may vacuum the filter clean. Cabinet Cleaning • Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry. • Never use harsh cleaners, wax or polish on the cabinet front. • Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner. • Plug in air conditioner. Winter Storage If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with plastic or return it to the original carton. NOTE: To prevent rust or electrical connections from being damaged, store air conditioner in an upright position and a dry place. A winter cover can be purchased from your dealer. The cover will protect the air conditioner when it is left in place through the winter. 7 Before calling for service, review this list. It may save you time and expense. This Avoid Service Checklist list includes common occurrences that are not the result of defective workmanship or materials in this appliance. OCCURRENCE SOLUTION Air conditioner will not operate. Wall plug disconnected. Push plug firmly into wall outlet. House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker. Selector Control in OFF position. Turn selector to ON (some models) or the desired FAN or COOL setting. Unit turned off and then on too quickly. Turn unit off and wait 3 minutes before restarting. Thermostat set too low. Adjust thermostat to higher number for cooling. Air from unit does not feel cold enough. Turn selector to a higher FAN or COOL position Compressor turned off by moving thermostat from a higher number to a lower number and then immediately back to a higher number. Wait approximately 3 minutes. Listen for compressor to start. Thermostat set too warm. Set thermostat to colder temperature. Room temperature below 70°F (21°C). Cooling may not occur until room temperature rises above 70°F (21°C). Temperature sensing tube touching cold coil, located behind air filter. Straighten tube away from coil. Air conditioner cooling, but room is too warm — ice forming on cooling coil behind decorative front. Outdoor temperature below 70°F (21°C). To defrost the coil, set selector to FAN position. Then, set thermostat to warmer position. Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set selector to FAN. Thermostat set too cold for night-time cooling. To defrost the coil, set selector to a FAN position. Then, set thermostat to a warmer position. Air conditioner cooling, but room is too warm — NO ice forming on cooling coil behind decorative front. Dirty air filter — air restricted. Clean air filter. Refer to Care and Cleaning section. ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie