Log:
valutazioni - 4, GPA: 4.3 ( )

Istruzioni per l'uso Danby, Modello DAC 5209M

Produttore : Danby
File Size : 439.25 kb
File Nome : 5edd06a5-7e55-4b7b-aa62-35f18cdd668e.pdf
Lingua di insegnamento: enfr
Vai a scaricare



Facilità d'uso


4. • Slide the shutters into the top (“L” Shaped) and bottom (“U” Shaped) channels. The shutters are identified (on frame) as left and right. 3) Completing the Installation • Cut the foam (non adhesive) sealing strip to fit the area of the window sill that the air conditioner will rest on. • Carefully place the air conditioner into the window with the “L” shaped mounting bracket (on top) positioned in front of the upper window sash. The bottom of the cabinet should be positioned on the “recessed” portion of the window frame. Pull the window down until it rests just behind the front flange of the (top) “L” shaped mounting bracket (See Fig. 5). • Expand the shutter frames (fully) on each side and secure the top of the frames to the window sash using one 3/4” screw on each side and one in the “L” shaped mounting bracket (Fig. 5). • Secure the shutter clamp on each side of the (lower) shutter and secure to window sill using one 3/4” screw on each side (Fig. 5). • Place the second foam sealing strip to fit the opening between the inside and outside windows, then attach the safety lock to the outside window frame using one 3/4” screw (See Fig. 6). PLEASE NOTE: Window applications come in a variety of different styles. Therefore, it may be necessary to modify or improvise your particular installation. 3/8” screws “L” shaped mounting bracket “U” shaped Channel(Factory Installed) Fig. 3 Slide down into tabs Shutter tabs Shutter Shutter frame Fig. 4 Window sash “L” ShapedMountingBracket Shutter clamps 3/4” screws Fig. 5 Safety Lock 3/4” screw Foam Seal Fig. 6 6 OPERATING INSTRUCTIONS The selector switch controls fan speed and/or cooling speed. To SELECTOR SWITCH set desired cooling temperature, simply rotate the SELECTOR knob to the appropriate setting. FAN SPEEDS • LOW FAN will circulate air at minimum speed without cooling. • HIGH FAN will circulate air at maximum speed without cooling. Thermostat COOLING MODES • LOW COOL provides cooling with minimum air circulation. Recommended for night-time use. • HIGH COOL provides cooling with maximum air circulation. Recommended for quick cooling or for extremely hot days. Once room is cooled, reduce setting to LOW COOL. • OFF shuts-down the unit completely Selector NOTE: Always allow 3 minutes before switching Switch from one mode to another. THERMOSTAT The thermostat automatically controls the (compressor) cooling cycle and maintains the selected room temperature. To set the thermostat, rotate the thermostat knob to the desired cooling setting (1 warmest - 7 coldest). The fan motor will continue to operate after the compressor (cooling) has cycled off. This is normal. When using FAN control, turn selector switch slowly, allowing unit to adjust. When using THERMOSTAT, be sure to allow three minutes before changing temperature. Adjusting too quickly may cause compressor to overload. 7 CARE AND MAINTENANCE When cleaning the air conditioner, be sure to turn the SELECTOR knob to the “OFF” position and disconnect the power cord from the electrical outlet. 1) DO NOT use gasoline, benzene, thinner, or any other chemicals to clean this unit, as these substances may cause damage to the finish and deformation of plastic parts. 2) Never attempt to clean the unit by pouring water directly over any of the surface areas, as this will cause deterioration of electrical components and wiring insulation. AIR FILTER If the air filter becomes clogged with dust, air flow is obstructed and reduces efficiency. The air filter should be cleaned every 2 weeks. AIR FILTER REMOVAL: The air filter is located behind the air intake front grill. To remove the air filter, grasp the filter handle on the front of the gril and slide it out to the right. To reinstall the air filter, reverse the above procedures. The air filter must be vacuumed or washed by hand in warm water. Dry thoroughly before re-installing. CLEANING AIR FILTER: 1) Use a vacuum cleaner with soft brush attachment 2) Wash the filter in lukewarm water below 40°C (104°F): To get best results, wash with soapy water or a neutral cleaning agent. 3) Rinse the filter with clean water and dry thoroughly before re-installing. IMPORTANT: DO NOT forget to install the air filter. If the air conditioner is left to operate without the air filter, dust is not removed from the room air and may result in machine failure. When the air inlet grill and cabinet are dirty, wipe with lukewarm water (below 40°C). Use of a mild detergent is recommended. END OF SEASON CARE 1) Operate the fan alone for half a day to dry out the inside of the unit. 2) Turn off power and remove plug from wall socket. 3) Clean filter. 4) Store (covered) air conditioner in a dry location. CAUTION: When installing and/or removing the air conditioner from the window, ensure that caution is taken to prevent it from falling backward. It is recommended that installation or removal of the air conditioner is done with assistance to prevent injury to persons or damage to the unit or property. 8 T...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie