Facilità d'uso


This low-ambient control shall regulate speed of the condenser-fan motors in response to the saturated condensing temperature of the unit. The control shall maintain correct condensing pressure at outdoor temperatures down to –20 F. 2. Gage Panel Package: Gage panel package shall include a suction and discharge pressure gage. 569D072- 120, 576C120, 569F120 31 569D072- 120, 576C120, 569F120 569D072- 120, 576C120, 569F120 GUIDE SPECIFICATIONS — 569F120 (cont) 3. Optional Condenser Coil Materials: a. Pre-Coated Aluminum-Fin Coils: Shall have a durable epoxy-phenolic coating to provide protection in mildly corrosive coastal environments. Coating shall be applied to the aluminum fin stock prior to the fin stamping process to create an inert barrier between the aluminum fin and copper tube. Epoxy-phenolic barrier shall minimize galvanic action between dissimilar metals. b. E-Coated Aluminum-Fin Coils: Shall have a flexible epoxy polymer coating uniformly applied to all coil surface areas without material bridging between fins. Coating process shall ensure complete coil encapsulation. Color shall be high gloss black with gloss requirements of 60° of 65 to 90% per ASTM D523-89. Uniform dry film thickness from 0.8 to 1.2 mil on all surface areas including fin edges. Superior hardness characteristics of 2H per ASTM D3363-92A and cross hatch adhesion of 4B-5B per ASTM D3359-93. Impact resistance shall be up to 160 in./lb (ASTM D2794-93). Humidity and water immersion resistance shall be up to a minimum of 1000 and 250 hours respectively (ASTM D2247-92 and ASTM D870-92). Corrosion durability shall be confirmed through testing to no less than 1000 hours salt spray per ASTM B117-90. Coil construction shall be aluminum fins mechanically bonded to copper tubes. 4. Thermostat Controls: a. Programmable multi-stage thermostat with 7-day clock, holiday scheduling, large backlit display, remote sensor capability, and Title 24 compliance. b. Commercial Electronic Thermostat with 7-day timeclock, auto-changeover, multi-stage capability, and large LCD temperature display. 5. Hail Guard Package: Hail guard package shall protect coils against damage from hail and other flying debris. 6. Condenser Coil Grille: Grille shall add decorative appearance to unit and protect condenser coil after installation. 7. Unit-Mounted, Non-Fused Disconnect Switch: Shall be factory-installed, internally mounted. NEC and UL approved non-fused switch shall provide unit power shutoff. Shall be accessible from outside the unit and shall provide power off lockout capability. 8. Convenience Outlet: Shall be factory-installed and internally mounted with easily accessible 115-v female receptacle. Shall include 15 amp GFI receptacle with independent fuse protection. Voltage required to operate convenience outlet shall be provided by a factory-installed step-down transformer. Shall be accessible from outside the unit. 32 MODEL NUMBER NOMENCLATURE 566DE X150 000–– 566DE X150 000–– 566D — Commercial Air-Cooled Condensing Unit With Semi-Hermetic Compressor 566E — Dual Circuit Commercial Air-Cooled Condensing Unit With Scroll Compressors Voltage Designation E — 460-3-60 P — 208/230-3-60 T — 575-3-60 Heating X—None *Contact your local representative for more details. QualityAssurance Certified to ISO 9001:2000 Factory-Installed Options* Heating Capacity 000 — No Heat Nominal Tons Cooling 150 — 12-1/2 180 —15 240 —20 566D/E150-240 33 PHYSICAL DATA 566D150-240 UNITS UNIT 566D150 566D240 NOMINAL CAPACITY (tons) 121/2 20 REFRIGERANT TYPE* R-22 566D180 15 OPERATING WEIGHTS (lb) Aluminum-Fin Coil (Standard) 779 789 929 Copper-Fin Coil (Optional) 919 929 1040 Operating Charge, Typical (lb)† 23 23 28 Shipping Charge (lb) 3.1 3.1 3.1 COMPRESSOR Reciprocating, Semi-Hermetic Qty...Model No. Cylinders Speed (rpm) Oil Charge (pt) Capacity Steps Accessory Standard Unloader Setting (psig) Load Unload Crankcase Heater Watts 1...06DD328 6 1750 10 33**, 66, 100 66, 100 Qty...Rpm Diameter (in.) Nominal Hp Nominal Airflow (cfm, total) Watts (total) CONDENSER COIL Copper Tubes, Aluminum Fins Rows...Fins/in. 3...15 Face Area (sqft) 29.2 Storage Capacity (lb)†† 48 1...06DD537 6 1750 10 33**, 66, 100 66, 100 70 ± 1 60 ± 2 125 CONDENSER FANS Axial Flow, Direct Drive 2...1075 26 1/2 11,000 1460 3...15 29.2 48 CONTROLS 395 ± 10 295 ± 20 27 ± 4 67 ± 7 FAN CYCLING CONTROLS 255 ± 10 160 ± 10 Liquid Line 200 1...06E4250 4 1750 15.5 — 50, 100 3...15 29.2 38 Pressurestat (psig) High Pressure Cutout Cut-in Low Pressure Cutout Cut-in Operating Pressure (psig) No. 2 Fan, Close Open PRESSURE RELIEF Location Temperature (F) 566D/E150- 240 13/8 13/8 15/8 Suction 5/8 Liquid Hot Gas Stub 3/8 PIPING CONNECTIONS (in. ODM) *Unit is factory-supplied with holding charge only. †Typical operating charge with 25 ft of interconnecting piping. Operating charge is approximate for maximum system capacity. **Indicates capacity step (%) with electric unloader accessory. ††Storage capacity is measured at liquid saturated ...

Questo manuale è adatto anche per i modelli :
Condizionatori - 566D (1.82 mb)
Condizionatori - 566E (1.82 mb)
Condizionatori - 569F (1.82 mb)
Condizionatori - 576C (1.82 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie