Log:
valutazioni - 3, GPA: 4.7 ( )

Istruzioni per l'uso Honeywell, Modello AMH-12000E

Produttore : Honeywell
File Size : 4.2 mb
File Nome :
Lingua di insegnamento: ruplsvhritentresfrdeetnlhuptdaficslvlt
Vai a scaricare



Facilità d'uso


Note : The warm air exchange hoses must vent inside the room when using Dehumidify Mode, not outside as it does when cooling. If the unit is vented outside some cooling will occur. 3. Fan Mode When fan mode is selected, , or will be shown in the LCD display. Air is circulated throughout the room with no cooling. Note: Unit does not need to be vented in Fan Mode. Fan Speed Control The Fan Speed Control has 3 settings: High; Medium; and Low. Time Setting Auto Shut Off: With machine in running mode, press the timer button. Press“+”or“-”to select number of hours you would like the unit to run before it automatically shuts off. Auto Turn On: With machine in stand-by mode, press the timer button. Press“+”or“-”to select number of hours before the unit automatically starts running in air conditioning mode. NOTE: Time is adjustable between 1-24 hours. Temperature Controls • The temperature control buttons are used for adjusting the thermostat. • The default LCD display is the room temperature. • In cooling mode, when“+”or“-”is pressed the set temperature is displayed and may be adjusted. After 15 seconds the display will revert back to showing the room temperature. Temperature is only adjustable in cool mode. NOTE: By pressing both the “+” and “-” buttons at the same time for more than 3 seconds, the display will toggle between Celsius and Fahrenheit. OPERATING INSTRUCTIONS: REMOTE Control The functions work the same a your air conditioner’s control panel. All key functions can be accessed from the remote control (Fig. 10). Power Control: On/Off Fan Speed Control: High; Medium; Low On/Off Timer Control: In running mode: Auto switch off In stand-by mode: Auto switch off Press“ ”or“ ”buttontoadjustthetimesettingin1hour intervals. Fahrenheit/Celsius Button: toggles between Celsius and Fahrenheit settings. LCD Display Time/Temperature Set Control: • Used for adjusting the timer and temperature. • The default display on the control panel is room temperature •When“ ”or“ ”buttonispressedincoolmodetheset temperature is displayed and may be adjusted. After 15 seconds the display will revert back to room temperature. •Timersettingisavailablefrom1- 4hoursbypressingthe“ ”or “ ”button.”button. Mode Control: Press to change the operating mode, which will rotate through Cool -Dehumidify -Fan and back to Cool. ENGLISH ENGLISH NOTE: • Do not drop the remote control. • DO not place the remote control in a location exposed to direct sunlight. • The remote control should be placed about 1 meter or more away from TV or any electrical appliance. Battery Replacement Remove the cover on the back of the remote control and insert the batteries with the + and – poles pointing in the proper direction (Fig. 11). CAUTION: Use only AAA or IEC R03 1.5V batteries. Remove the batteries if the remote control is not used for a month or longer. Do not attempt to recharge the supplied batteries. All batteries should be replaced at the same time; do not mix old and new batteries. Do not dispose of the batteries in a fire, as they may explode. TROUBLESHOOTING The following cases may not always be a malfunction; please check your unit before asking for service. My air conditioner does not run. • Check to see if the protector trip or a fuse is blown • Please wait for 3 minutes and start again. • The batteries in the remote might need replacing. • Check to see if the plug is properly plugged in. My air conditioner runs for only a short time. • The temperature might be set close to the existing room temperature. • An air outlet might be blocked. My air conditioner runs, but is not cooling. • A door or window may be open. • There may be a heater or lamp in operation • The air filter may need to be cleaned. • An air outlet or intake may be blocked. • The temperature may be set too high. My air conditioner will not run, and the WATER FULL indicator light is on. • Drain the water into a prepared container by the drainage pipe on the rear panel of the unit. • If this does not work, please consult a qualified technician. MAINTENANCE Appliance Maintenance 1. Cut off the power supply. Turn off the appliance first before disconnecting from power supply. . Wipe with a soft, dry cloth. Use lukewarm water (below 40°C/104°F) and a soft, damp cloth to clean the appliance if it is very dirty. 3. Never use volatile substances such as gasoline or polishing powder to clean the appliance. 4. Never sprinkle water onto the main unit. It is dangerous and electric shock may result. Air Filter Maintenance It is necessary to clean the air filter after using it for about 100 hours. Clean it as follows: 1. Stop the appliance and remove the air filter. . Clean and reinstall the air filter. If the dirt is conspicuous, wash it with a solution of detergent in lukewarm water. After cleaning, dry it in a shaded and cool place, then reinstall it. 3. Clean the air filter every two weeks if the air conditioner operates in an extremely dusty environment. Maintenance Before Storage 1. If the appl...

Questo manuale è adatto anche per i modelli :
Condizionatori - AMH-10000E (4.2 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie