Log:
valutazioni - 2, GPA: 3.5 ( )

Istruzioni per l'uso York, Modello CSA DH 036

Produttore : York
File Size : 603.8 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


HACR Type per NEC. 2. These electric heaters do not include a fuse box. If a fuse box is required to meet a local code (i.e. Chicago), the fuse block accessories 2FB04700825 and 2FB04700846 are available for field installation. Unitary Products Group 254597-YTG-B-0507 254597-YTG-B-0507 MODEL TONNAGE VOLTAGE COMPRESSORS OD FAN MOTOR FLA ID BLOWER MOTOR FLA CONV OUTLET FLA ELECTRIC HEATER MODEL NO. HEATER KW HEATER AMPS MIN. CIRCUIT AMPACITY (AMPS) MAX. FUSE/ BRKR1 SIZE (AMPS) RLA EACH LRA EACH DH036 208-3-60 13.1 110.0 2.3 8.0 10.0 None -- 36.7 45 2CE045105252 4.0 11.1 36.7 45 2CE045107252 5.6 15.5 41.9 45 2CE04511025 8.0 22.2 50.3 60 2CE04511525 11.9 33.0 63.8 70 2CE04512025 15.9 44.1 77.7 80 230-3-60 13.1 110.0 2.3 8.0 10.0 None -- 36.7 45 2CE045105252 5.3 12.7 38.4 45 2CE045107252 7.5 18.0 45.1 50 2CE04511025 10.6 25.5 54.4 60 2CE04511525 15.9 38.2 70.3 80 2CE04512025 21.2 51.0 86.2 90 DH048 208-3-60 13.1 110.0 2.3 10.6 10.0 None -- 39.3 50 2CE045105252 4.0 11.1 39.6 50 2CE045107252 5.6 15.5 45.2 50 2CE04511025 8.0 22.2 53.5 60 2CE04511525 11.9 33.0 67.0 70 2CE04512025 15.9 44.1 80.9 90 230-3-60 13.1 110.0 2.3 10.6 10.0 None -- 39.3 50 2CE045105252 5.3 12.7 41.7 50 2CE045107252 7.5 18.0 48.3 50 2CE04511025 10.6 25.5 57.6 60 2CE04511525 15.9 38.2 73.6 80 2CE04512025 21.2 51.0 89.5 90 DH060 208-3-60 16.0 137.0 2.3 10.6 10.0 None -- 42.9 50 2CE045105252 4.0 11.1 42.9 50 2CE045107252 5.6 15.5 45.2 50 2CE04511025 8.0 22.2 53.5 60 2CE04511525 11.9 33.0 67.0 70 2CE04512025 15.9 44.1 80.9 90 2CE04513025 22.2 61.6 102.8 110 230-3-60 16.0 137.0 2.3 10.6 10.0 None -- 42.9 50 2CE045105252 5.3 12.7 42.9 50 2CE045107252 7.5 18.0 48.3 50 2CE04511025 10.6 25.5 57.6 60 2CE04511525 15.9 38.2 73.6 80 2CE04512025 21.2 51.0 89.5 90 2CE04513025 29.6 71.2 114.8 125 1. HACR Type per NEC. 2. These electric heaters do not include a fuse box. If a fuse box is required to meet a local code (i.e. Chicago), the fuse blockaccessories 2FB04700825 and 2FB04700846 are available for field installation. Unitary Products Group 254597-YTG-B-0507 254597-YTG-B-0507 MODEL TONNAGE VOLTAGE COMPRESSORS OD FAN MOTOR FLA ID BLOWER MOTOR FLA CONV OUTLET FLA ELECTRIC HEATER MODEL NO. HEATER KW HEATER AMPS MIN. CIRCUIT AMPACITY (AMPS) MAX. FUSE/ BRKR1 SIZE (AMPS) RLA EACH LRA EACH DH036 (3.0) 208-3-60 13.1 110.0 2.3 5.2 10.0 None -- 33.9 45 2CE045105252 4.0 11.1 33.9 45 2CE045107252 5.6 15.5 38.4 45 2CE04511025 8.0 22.2 46.8 50 2CE04511525 11.9 33.0 60.3 70 2CE04512025 15.9 44.1 74.2 80 230-3-60 13.1 110.0 2.3 5.2 10.0 None -- 33.9 45 2CE045105252 5.3 12.7 34.9 45 2CE045107252 7.5 18.0 41.6 45 2CE04511025 10.6 25.5 50.9 60 2CE04511525 15.9 38.2 66.8 70 2CE04512025 21.2 51.0 82.7 90 460-3-60 6.7 54.0 1.3 2.6 5.0 None -- 17.3 20 2CE045107462 6.8 8.2 19.7 20 2CE045110462 10.1 12.1 24.7 25 2CE045115462 13.6 16.4 29.9 30 2CE045120462 19.5 23.5 38.8 40 DH048 (4.0) 208-3-60 13.1 110.0 2.3 5.2 10.0 None -- 33.9 45 2CE045105252 4.0 11.1 33.9 45 2CE045107252 5.6 15.5 38.4 45 2CE04511025 8.0 22.2 46.8 50 2CE04511525 11.9 33.0 60.3 70 2CE04512025 15.9 44.1 74.2 80 230-3-60 13.1 110.0 2.3 5.2 10.0 None -- 33.9 45 2CE045105252 5.3 12.7 34.9 45 2CE045107252 7.5 18.0 41.6 45 2CE04511025 10.6 25.5 50.9 60 2CE04511525 15.9 38.2 66.8 70 2CE04512025 21.2 51.0 82.7 90 460-3-60 6.7 54.0 1.3 2.6 5.0 None -- 17.3 20 2CE045107462 6.8 8.2 19.7 20 2CE045110462 10.1 12.1 24.7 25 2CE045115462 13.6 16.4 29.9 30 2CE045120462 19.5 23.5 38.8 40 575-3-60 5.1 44.0 1.3 2.0 4.0 None -- 13.4 15 2CE04511058 10.6 10.2 20.2 25 2CE04511558 15.9 15.3 26.6 30 2CE04512058 21.2 20.4 33.0 35 DH060 (5.0) 208-3-60 16.0 137.0 2.3 5.2 10.0 None -- 37.5 50 2CE045105252 4.0 11.1 37.5 50 2CE045107252 5.6 15.5 38.4 50 2CE04511025 8.0 22.2 46.8 50 2CE04511525 11.9 33.0 60.3 70 2CE04512025 15.9 44.1 74.2 80 2CE04513025 22.2 61.6 96.0 100 230-3-60 16.0 137.0 2.3 5.2 10.0 None -- 37.5 50 2CE045105252 5.3 12.7 37.5 50 2CE045107252 7.5 18.0 41.6 50 2CE04511025 10.6 25.5 50.9 60 2CE04511525 15.9 38.2 66.8 70 2CE04512025 21.2 51.0 82.7 90 2CE04513025 29.6 71.2 108.0 110 460-3-60 8.3 69.0 1.3 2.6 5.0 None -- 19.3 25 2CE045107462 6.8 8.2 19.7 25 2CE045110462 10.1 12.1 24.7 25 2CE045115462 13.6 16.4 29.9 30 2CE045120462 19.5 23.5 38.8 40 2CE045130462 28.8 34.6 52.8 60 575-3-60 6.4 58.0 1.3 2.0 4.0 None -- 15.0 20 2CE04511058 10.6 10.2 20.2 25 2CE04511558 15.9 15.3 26.6 30 2CE04512058 21.2 20.4 33.0 35 2CE04513058 30.4 29.3 44.1 45 1. HACR Type per NEC. 2. These electric heaters do not include a fuse box. If a fuse box is required to meet a local code (i.e. Chicago), the fuse block accessories 2FB04700825 and 2FB04700846 are available for field installation. Unitary Products Group 254597-YTG-B-0507 254597-YTG-B-0507 MODELS DH 036 048 060 EVAPORATOR BLOWER Centrifugal Blower (Dia. x Wd. in.) 12 X 10 12 X 10 12 X 10 Fan Motor HP (Direct Drive) 3/4 1 1 Fan Motor HP (Belt Drive) 1 1/2 1 1/2 1 1/2 EVAPORATOR COIL Rows Deep 4 4 4 Fins Per Inch 13 13 13 Face Area (Sq. Ft.) 4.3 5.1 5.1 CONDENSER FANS Propeller Dia. (in.) 24 24...

Questo manuale è adatto anche per i modelli :
Condizionatori - CSA 48 (603.8 kb)
Condizionatori - CSA 60 (603.8 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie