|
Facilità d'uso
2 Connect to electrical power. 3 See the special instructions below for applicable supply voltages. 4 Reinstall the room cabinet. Branch Circuit and Proper GE Unit Amperage Rating Subbase Kit 15/20 RAK204D20 30 RAK204D30 230/208 VOLT ELECTRICAL SUPPLY All wiring, including installation of the receptacle, must be in accordance with the NEC and local codes, ordinances and regulations. This unit is equipped with a line cord for appropriate amperage wall receptacle. See below. Electrical subbases provide a flexible enclosure for direct connection or enclosed receptacles. The instructions provided with the selected subbase kit must be carefully followed. It is the responsibility of the installer to ensure the connection of components is done in accordance with these instructions and all electrical codes. Tandem Perpendicular Large Tandem 15 Amp. 20 Amp. 30 Amp. 230/208 volt receptacle configuration. Order Kit RAK4002A for 230/208 volt direct connection. 14 Installation Instructions 265 VOLT ELECTRICAL SUPPLY WARNING: Connection of this 265 V AC product to a branch circuit MUST be done by direct connection in accordance with the National Electric Code. Plugging this unit into a building mounted exposed receptacle is not permitted by code. These models must be installed using one of the following methods: A Electrical subbase kits are available to provide a flexible enclosure for direct connection. Branch Circuit and Proper GE Unit Amperage Rating Subbase Kit 15 RAK204E15 20 RAK204E20 30 RAK204E30 The instructions provided with the selected subbase kit must be carefully followed. It is the responsibility of the installer to ensure the connection of components is done in accordance with these instructions and all electrical codes. B For direct connection to branch circuit wiring inside the provided junction box without using a subbase kit, cut the cord, strip the wire ends and connect as follows. 1 REMOVE JUNCTION BOX 1 Remove the junction box cover by taking out the front two screws. 2 Remove the junction box by taking out the top and bottom rear screws. Note how the tabs on the lower left side of the junction box serve to hold the side in place. This will help when the box is being reinstalled. The cord will be coiled up inside the junction box. Junction box cover Junction box 2 CUT AND STRIP THE CORDSET 1 Measure 6. down the cord from the strain relief securing the cord to the unit and cut the cord through at this point. 2 Carefully split the cord insulation at the center for 2. so as to separate into three insulated wires. Be careful not to cut through the center green ground wire insulation. 3 Strip 3/4. of the insulation away at the end of each of the three wires (L1, Neutral and Ground). The Neutral wire is identified by molded rib along its entire length. The L1 (Hot) wire insulation is smooth. Strain relief 6. 2. 3/4. Neutral wire (molded rib) Ground wire L1 wire (smooth) 15 Installation Instructions 265 VOLT ELECTRICAL SUPPLY ATTACH CONDUIT 1 Use the round knockout at the bottom of the junction box to attach conduit coming from the branch circuit. Remove the knockout, attach the conduit and bring wires into the junction box. Leave 6. of wire free at the end of the conduit to allow connections to be made. 2 If a fuse and fuseholder are to be used, the knockout at the top of the box is for mounting a Buss Fuseholder. Be sure the fuse and fuseholder are of the same rating as the branch circuit. Leadwires at the fuse can be either soldered in place or attached using UL-listed 1/4. female (receptacle) crimp connectors. 3 Conduit 4 REINSTALL JUNCTION BOX • Reinstall the junction box by engaging the left tabs on the lower right face of the unit, aligning the screw holes at the top and bottom and driving the two screws until secure. Be sure that all wire leads are inside the box and not pinched between the box and the unit. The identified (ribbed) Neutral wire of the cordset MUST be connected to the white Neutral wire of the branch circuit. The green insulated ground wire from the unit MUST be connected to the branch circuit ground wire. NOTE: Order Kit RAK4002CW to enable a quick disconnect inside the junction box. 5 MAKE WIRING CONNECTIONS 1 Make all wire connections by using appropriate UL-listed electrical connectors and techniques (black to black, white to white and green to green). 2 Carefully tuck all wires and connections back inside the junction box. Be sure there are no loose connections or stray uninsulated wires exposed. 3 Place the junction box cover in place. Replace the two screws removed earlier and tighten securely. 4 Discard the unused portion of the plug and the cordset. 16 Installation Instructions INSTALLING THE ZONELINE 1 INSTALL THE WALL CASE AND EXTERIOR GRILLE The RAB71 series or RAB77 wall case must be properly installed per instructions packed with the case. • Remove the corrugated stiffener and the outdoor protective panel. Use the slit in the outdoor panel as a handhold and push out. ...
Questo manuale è adatto anche per i modelli :Condizionatori - 2500 (1.57 mb)