Log:
valutazioni - 2, GPA: 3.5 ( )

Istruzioni per l'uso Panasonic, Modello CWXC100HU

Produttore : Panasonic
File Size : 1.97 mb
File Nome : CWXC100HU.PDF
Lingua di insegnamento: enes
Vai a scaricare



Facilità d'uso


at 72°F (22°C). ®MODE • Every time you push this button, it will toggle between COOL, FAN and DRY. (D ON/OFF TIMER • Every time you push the TIMER button, timer is set as follows. (1Hour ^ 2Hours ^ 3Hours ^ 4Hours ^ 5Hours 6Hours ^ 7Hours ^ 8Hours ^ 9Hours ^ 10Hours 11Hours ^ 12Hours ^ 0) • The Setting Temperature will be raised by 2°F (1°C) 30 min. later and by 2°F (1 °C) after another 30 min. ®FAN SPEED • Every time you push this button it is set as follows. {High(F3) ^ Low(F1) ^ Med(F2) ^ High(F3)...}. © TEMPERATURE SETTING • This button can automatically control the temperature of the room. The temperature can be set within a range of 60°F to 86°F by 1°F(16°C to 30°C by 1°C). Select the lower number for lower temperature of the room. © REMOTE CONTROL SIGNAL RECEIVER ®DRY • When this unit is in dry mode, the fan rotates in low speed. The fan stops when the compressor stops cooling. Approximately every 3 minutes the fan will turn on and the unit checks the room air temperature to set itself. 5 About the Controls on the Air Conditioner About the Controls on the Air Conditioner Remote controller Precaution: The Remote Controller will not function properly if strong light strikes the sensor window of the air conditioner or if there are obstacles between the Remote Controller and the air conditioner. Models: CW-XC100HU, CW-XC120HU Panasonic V_/ © OPERATION • To turn the air conditioner ON, push the button. To turn the air conditioner OFF, push the button again. • This button takes priority over any other buttons. • When you first turn it on, the air conditioner is on the High cool mode and the temp. at 72°F(22"C). (2) MODE • Every time you push this botton,it will toggle between COOL, FAN and DRY. ® ON/OFF TIMER - STOPPING OPERATION • Every time you push this button, when the air conditioner is operating, timer is set as follows. (IHour ^ 2Hours ^ 3Hours ^ 4Hours ^ 5Hours ^ 6Hours ^ 7Hours ^ 8Hours ^ 9Hours ^ 10Hours ^ 11Hours ^ 12Hours ^ O). • The Setting Temperature will be raised by 2°F (1 °C) 30 min. later and by 2°F (1 °C) after another 30 min. - STARTING OPERATION • Every time you push this button, when the air conditioner is not operating, timer is set as follows. (IHour ^ 2Hours ^ 3Hours ^ 4Hours ^ 5Hours ^ 6Hours ^ 7Hours ^ 8Hours ^ 9Hours ^ 10Hours ^ 11Hours ^ 12Hours ^ O) © FAN SPEED • Every time you push this button it is set as follows. {High(F3) ^ Low(F1) ^ Med(F2) ^ High(F3)...}. © TEMPERATURE SETTING • This button can automatically control the temperature of the room. The temperature can be set within a range of 60° F to 86°F by 1°F(16"C to 30"C by 1"C). Select the lower number for lower temperature of the room. 6 Additional controls and important information. Ventilation The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When fresh air is necessary in the room, set the ventilation lever to the OPEN position. The damper is opened and room air is drawn out. CLOSE^ta VENTIL OPEN NOTE: Before using the ventilation feature, and prior to installing the front grille, pull down part @ until level with part ®. Air Direction The direction of air can be controlled wherever you want to cool by adjusting the horizontal louver and the vertical louver. • VERTICAL AIR-DIRECTION CONTROL Controlled manually HORIZONTAL AIR-DIRECTION CONTROL Controlled manually The vertical air direction is adjusted by rotating the horizontal louver forward or backward manually. The horizontal air direction is adjusted by rotating the vertical louver right or left manually or by Remote Controller. How to Secure the Drain Pipe In humid weather, excess water may cause the BASE PAN to overflow. To drain the water, remove the DRAIN CAP and secure the DRAIN PIPE to the rear hole of the BASE PAN. Press the drain pipe into the hole by pushing down and away from the fins to avoid injury. (See Fig.1) Optional (CW3H02502B) 1. Remove the rubber plug and slide the chassis out from the cabinet. (See Fig. 2) 2. Install the drain pan over the corner of the cabinet where you removed the plug with 4 (or 2) screws. (See Fig.3) 3. Connect the drain hose to the outlet located at the bottom of the drain pan. You can purchase the drain hose or tubing locally to satisfy your particular needs. (Drain hose is not supplied). (See Fig.3) 4. Select the most appropriate connection from among the figures to the right (by considering the hole of the unit) to fit drain pan to your own unit. (See Fig.3) 5. Slide the chassis back into the cabinet. Reinstall the cabinet screws. Secure the cabinet to chassis by using screws. (See Fig.4) 7 Drain pipe . ! Drain cap © Push 4 Fig. 1 Remove the ! rubber plug ^ 1 Fig. 2 ^|||| J SCREW cAB\ljli^^5 DRAIN nr'"'"--DRAIN HOSE PAN Inside diameter 17mm (5/8") Fig. 3 1 Fig. 4 About the Controls on the Air Conditioner About the Controls on the Air Conditioner Care and Maintenance TURN THE AIR CONDITIONER ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie