|
Facilità d'uso
Fix the swing plate at the bottom. 2. Dismantle the swing plate. CAUTION! Use water to clean the plate and don't heavily scrub, otherwise the fine hair may fall off. Unscrew the screw at both ends of the swing plate. [Dismantle and install swingplate ] 3. Install swing plate Lightly rotate swing plate to insert the ridge at both ends of the outlet into the groove and then screw up. 2. Take off air-filter 9 Maintenance (For series 36 42 52 ) Clean the air filter Instructions : When not for cleaning, do not dismantle the air filter, otherwise it may cause trouble. When the air conditioner is used in a dusty environment, the air filter should be cleaned more often (generally once every two weeks). Open 1. Open air inlet grille Pull the two handles at the same time, slowly draw them out. (when closing it, the procedure is reversed.) 2.Dismantle the air filter Pull the two side handles at the back of the air inlet grille, lift the air filter to dismantle it. 3. Clean Notice Do not use the hot water over 50 C to clean to avoid discoloration or deformation. Do not dry the unit on fire, the filter may be burnt. Use cleaner or water to clean to remove dust. (A) Use cleaner to remove dust. Open and remove (B) When the dust is too much, use soft brush and neutral detergent. (C) Throw the water off, then put it in the shadow for airing. 10 Maintenance 4. Install air filter (1)Put the air filter into those extruding parts at the top of the air inlet grille. 5. Close air inlet grille Referring to procedure 1. Clean the air inlet grille 1. Open air inlet grille (2)Draw the handles at the back of the air inlet grille inwards to fix the air filter. Pull the two handles at the same time, slowly draw them Open out. (when closing it, the procedure is reversed.) 2. Remove air filter Referring to iClean the air filteri. 3. Remove the air inlet grille Open the air inlet grille for 45 , the lift it up. 4. Clean Notice Do not use the hot water over 50 C to clean to avoid discoloration or deformation. Use soft brush, water and neutral detergent to clean, then throw the water off. Instruction [ When there is too much dust ] Use ventilation fan or directly spray the detergent special for kitchen ware on the air inlet grille, 10 minutes later use water to clean. 5. Install air inlet grille Referring to procedure 3. 6. Install the air filter Referring to iClean the air filteri 7. Close air inlet grille Referring to procedure 1. 11 Maintenance Seasonal Reserve Post-season Care Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well. Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in stop. Clean the air filter, indoor unit and outdoor unit,and cover the unit with dustcoat. Pre-season Care See that there is no obstacles blocking the air inlet and air outlet of both indoor and outdoor unit to avoid reduce the working efficiency. Be sure to install the air filter, ensure that the air filter is not dirty. Otherwise may result in machine damages or cause malfunciton due th dust inside the unit To prevent compressor when start in HEAT mode, please cut in the power supply switch 12 hours before starting run,furthermore, always keep the power supply switch on during the using senson. NOTE 1. The inner part of indoor unit must be cleaned. Consult dealer, because clean must be done by technician. 2. In cooling operation, discharging system discharge water in room. 12 Trouble Shooting The followings are not malfuncition Hua Hua Water flowing sound is heard When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it sometimes sounds i Bi- Bi-i or iGodo-Godoi. It is the flowing sound of the refrigerant , not a malfunction. Cracking sound is heard This is caused by heat expansion or contraction of plastics It smells. Air blown out from the indoor unit sometimes smells. The smell results from smells of furniture, paint , tobacco absorbed by indoor unit. During operation, white fog comes out of indoor unit. When in COOL or DRY mode, a thin water fog can be seen blown out of unit ,this is the condensed fog because the suddenly cooled indoor air is blown out. Automatically switch into FAN mode during cooling. To prevent frost from being accumulated on the indoor unit heat exchanger, it sometimes automatically switched into the FAN mode,but it will soon back to the cooling mode. The air conditioner cannot be restarted soon after it stops. Air conditioner does not start? This is because of the self-protection function of the system, therefore,it cannot be restarted for about three minutes after it stops. Please wait for three minutes 13 Trouble Shooting Air does not blow or the fan speed cannot be changed during drying. In DRY mode, when room temperature becomes 2 C higher than temperature setting, unit rill run intermittently at LO speed regardless of FAN setting Water or vapor genera...
Questo manuale è adatto anche per i modelli :Condizionatori - AB142ACBEA (745.11 kb)
Condizionatori - AB242ACBEA (745.11 kb)
Condizionatori - AB28NACBEA (745.11 kb)
Condizionatori - AB36NACBEA (745.11 kb)