|
Facilità d'uso
ELECTRIC EXPANSION VALVE CN12 B6B-XASK-1-A WHITE CN12-4 UL1430 AWG24 ORANGE CN12-1 UL1430 AWG24 RED CN12-2 UL1430 AWG24 BROWN CN12-3 UL1430 AWG24 BLUE CN12-5 UL1430 AWG24 YELLOW CN12-6 UL1430 AWG24 WHITE CN14-1 UL1015 AWG20 BLUE CN14-2 UL1015 AWG20 BLUE HIGH PRESSURE SWITCH PRES. SW CN11 B6B-XAKK-1-A BLACK THERMISTOR CN1 B3P5-VH-B-C BLACK CN2 B2P3-VH-B-Y YELLOW CN3 B4P7-VH-B-R RED CN4 B2P3-VH-B-Y YELLOW CN5 B4P7-VH-B WHITE CN6 179844-1 WHITE CN7 179844-4 YELLOW CN8 B2P3-VH-B-R RED K7 FTR-F3A K6 FTR-F3A K5 FTR-F3A K3 FTR-F3A K4 G5S-1 C7 0.22 C8 0.22 R59 120 <1/2W> R60 120 <1/2W> K1 FTR-F3A K2 G5S-1 C6 0.22 R58 120 <1/2W> CN2-1 CN2-2 CN3-1 CN3-2 CN3-3 CN3-4 CN4-1 CN4-2 CN5-1 CN5-2 CN5-3 CN5-4 CN7-1 CN7-2 CN8-2 CN8-1 CN6-2 BLACK CN6-1 BLACK UL1015 AWG20 BLACK WHITE RED BLUE UL1015 AWG20 UL1015 AWG20 UL1015 AWG20 YELLOW UL1015 AWG20 YELLOW UL1015 AWG20 BLUE UL1015 AWG20 RED UL1015 AWG20 WHITE UL1015 AWG20 BLACK UL1015 AWG20 YELLOW UL1015 AWG20 YELLOW UL1015 AWG20 UL1015 AWG22 RED UL1015 AWG22 PINK UL1015 AWG22 BLACK UL1015 AWG22 WHITE UL1015 AWG18 UL1015 AWG18 WHITE BLACK UL1015 AWG14 WHITE UL1015 AWG16 BROWN UL1015 AWG14 RED UL1015 AWG14 BLACK R ST N MAGNETIC RELAY E R S T N 1 2 3 4WV COMP. A COMPRESSOR-A POWER SOURCE 415 / 380V 50Hz W1 INDOOR UNIT FAN CAPACITOR-1 FAN CAPACITOR-2 FAN MOTOR 1 FAN MOTOR 2 I C 1 EXPANSION VALVE FIRST PULSE SWITCHING FOR LONG PIPING (E.E.V.) SPARE R20 6.65K (1%)<1/10W> R19 6.65K (1%)<1/10W> R18 14K (1%)<1/10W> R17 38.3K (1%)<1/10W> PIPE TEMP. R0=16.05K B0/25=3873K OUTDOOR TEMP. R25=10.00K B25/50=3950K DISCHARGE TEMP. R100=3.43K B50/100=4012K CONTROLLER PCB ASSEMBLY K04DF-0402HUE-C1 uPD780076GK -649-9ET-A C1 0.22 SPARE OUTDOOR PCB CIRCUIT DIAGRAM DIP-SW setting SW1-1 SW1-2 SW1-3 Expansion valve first pulse switching for long piping Spare Spare Function on off Long piping mode Normal mode -- -- -- -- Model : RO-36UA 2005.07.29 9 ERROR CONTENTS 1. INDOOR UNIT Operation can be checked by lighting and flashing of the display section OPERATION, TIMER, and VERTICAL SWING lamps. Perform judgment in accordance with the following. SWING SWING TIMER MANUAL AUTO OPERATION VERTICAL SWING lamp (Orange) TIMER lamp (Green) OPERATION lamp (Red) TEST RUNNING When the air conditioner is run by pressing the remote control unit test run button, the OPERATION, TIMER, and VERTICAL SWING lamps flash slowly at the same time. ERROR The OPERATION, TIMER, and VERTICAL SWING lamps operate as follows according to the error contents. 2. OUTDOOR UNIT LEDS Heat & Cool model (reverse cycle) only When a malfunction occurs in the outdoor unit, the LEDs on the circuit board light to indicate the error. Refer to the following table for the description of each error according to the LEDs. LED2 LED1 LED layout LED1 LED2 Error contents flash flash Model abnormal or EEPROM abnormal 1flash Lighting Power source connection error 2 flash Lighting Discharge temp. sensor error 3 flash Lighting Heat exchanger temp. sensor error 4 flash Lighting Outdoor temp. sensor error 5 flash Lighting Communication signal error 6 flash Lighting Indoor unit error 7 flash Lighting Discharge temp. abnormal 8 flash Lighting High pressure abnormal 9 flash Lighting Compressor temp. abnormal 10 flash Lighting Compressor temp. sensor error Dislighting No error. Protect operation When the fault is cleared, the LED lamp goes off. However, for discharge pipe temperature abnormal and high pressure abnormal, the LED lamp lights continuously for 24 hours, as long as the power is not turned off. OPERATION lamp (RED) TIMER lamp (GREEN) SWING lamp (ORANGE) Error contents Indoor EEPROM abnormal Outdoor EEPROM abnormal (2 times) Indoor room temperature sensor open (2 times) Indoor room temperature sensor shor...
Questo manuale è adatto anche per i modelli :Condizionatori - RO-36FA (5.99 mb)
Condizionatori - RO-36UA (5.99 mb)
Condizionatori - RY-36UA (5.99 mb)
Condizionatori - RO-36UA (5.99 mb)