Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Kenmore, Modello CS-TE9DKE

Produttore : Kenmore
File Size : 7.66 mb
File Nome :

Lingua di insegnamento: en

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


Ensure the hooks are properly seated on the installation plate by moving in left and right. Indoor unit Hooks at installation plate Sleeve for piping hole Piping Drain hose ^Secure the Indoor Unit ^ 1. Tape the extra power supply cord in a bundle and keep it behind the chassis. • Ensure that the power supply cord is not clamped in between the unit's hook (2 positions) and installation plate. 2. Press the lower left and right side of the unit against the installation plate until hooks engages with their slots (sound click). Unit’s hook To take out the unit, push the I PUS Hi marking at the bottom unit, and pull it slightly towards you to disengage the hooks from the unit. push marking (This can be used for left rear piping & left bottom piping also.) * How to pull the piping and drain hose out. in case of the embedded piping. Apply putty or caulking material to seal the wall opening PVC tube tor dram hose (VP-20) Connecting cable Piping PVC tube for drain hose Cable Piping ' Drain hose from main unit PVC tube (VP-65) for piping and connecting cable PVC tube lor dram hose (VP-30) In case of left piping how to insert the connecting cable and drain hose. Drain hose Pipings Cable (For the right piping, follow the same procedure) 44 ICS-TE9DKE CU-TE9DKE / CS-TE12DKE CU-TE12DKE 11.2.5. CONNECT THE CABLE TO THE INDOOR UNIT 1.The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 * 1.5 mm2 flexible cord, type designation 245 IEC 57 (H05RN-F) or heavier cord. • Ensure the color of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively. • Earth lead wire shall be longer than the other lead wires as shown in the figure for the electrical safety in case of the slipping out of the cord from the anchorage. HOW TO TAKE OUT FRONT GRILLE | Terminals on the indoor unit | 1~ Color of wires Terminals on the outdoor unit 1 • Secure the cable onto the control board with the holder (clamper). INSTALLATION OF SUPER ALLERU-BUSTER FILTER 1. Open the front panel. 2. Remove the air filters. 3. Put Super Alleru-buster filter into place as shown in illustration below. © Super alleru-buster fi liter (5] Air filter Please follow the steps below to take out front grille if necessary such as when servicing. I.Set the vertical airflow direction louver to the horizontal position. 2. Slide down the two caps on the front grille as shown in the illustration below, and then remove the two mounting screws. 3. Pull the lower section of the front grille towards you to remove the front grille. Caution When reinstalling the front grille, first set the vertical airflow direction louver to the horizontal position and then carry out above steps 2 - 3 in the reverse order. Vertical airflow deflection louver (Move the vertical vane to horizontal) AUTO SWITCH OPERATION The below operations will be performed by pressing the “AUTO” switch. 1. AUTO OPERATION MODE The Auto operation will be activated immediately once the Auto Switch is pressed. 2. TEST RUN OPERATION (FOR PUMP DOWN/SERVICING PURPOSE) The Test Run operation will be activated if the Auto Switch is pressed continuously for more than 5 sec. to below 8 sec. A “pep” sound will occur at the fifth sec., in order to identify the starting of Test Run operation. 45 ICS-TE9DKE CU-TE9DKE / CS-TE12DKE CU-TE12DKE 11.3. OUTDOOR UNIT 11.3.1. SELECT THE BEST LOCATION (Refer to “Select the best location” section) 11.3.2. INSTALL THE OUTDOOR UNIT • After selecting the best location, start installation according to Indoor/Outdoor Unit Installation Diagram. 1. Fix the unit on concrete or rigid frame firmly and horizontally by bolt nut. (010 mm). 2. When installing at roof, please consider strong wind and earthquake. Please fasten the installation stand firmly with bolt or nails. 11.3.3. CONNECTING THE PIPING Connecting The Piping To Indoor Unit Please make flare after inserting flare nut (locate at joint portion of tube assembly) onto the copper pipe. (In case of using long piping) Connect the piping • Align the center of piping and sufficiently tighten the flare nut with fingers. • Further tighten the flare nut with torque wrench in specified torque as stated in the table. MODEL Piping size (Torque) Gas Liquid TE9CK 3/8” (42 N.m) 1/4” (18 N.m) TE12CK 1/2” (55 N.m) 1/4” (18 N.m) Connecting The Piping To Outdoor Unit Decide piping length and then cut by using pipe cutter. Remove burrs from cut edge. Make flare after inserting the flare nut (located at valve) onto the copper pipe. Align center of piping to valves and then tighten with torque wrench to the specified torque as stated in the table. Cutting And Flaring The Piping 1. Please cut using pipe cutter and then remove the burrs. 2. Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused. T...

Questo manuale è adatto anche per i modelli :
Condizionatori - CS-TE12DKE (7.66 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie