Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Bard, Modello WL6023

Produttore : Bard
File Size : 280.08 kb
File Nome :

Lingua di insegnamento: en

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


patent numbers: 5,485,878; 5,301,777; 5,002,116; 4,924,934; 4,875,520; 4,825,936; 4,432,409 Manual 2100-351 Page 1 WALL MOUNT GENERAL INFORMATION AIR CONDITIONING WALL MOUNT MODEL NOMENCLATURE CONTROL MODULES MODEL NUMBER WL 60 2 3 A 10 X N X X X A CAPACITY COIL OPTIONS 60 - 5 Ton X -Standard 1 -Phenolic Coated Evaporator COLOR OPTIONS 2 -Phenolic Coated Condenser REVISIONS KW X -Beige (Standard) 3 -Phenolic Coated Evaporator FEATURE CODE 1 -White and Condenser 3 -3 ton air openings 2 -Mesa Tan on 5 ton cabinet VOLTS & PHASE 4 -Buckeye Gray OUTLET OPTIONS 2 -2 ton air openings A -230/208/60/1 VENTILATION OPTIONS X -Front (Standard) on 5 ton cabinet B -230/208/60/3 B -Blank-off Plate FILTER OPTIONS N -No Filter WL4823, WL6023, WL602N models ONLY X -One Inch Throwaway Filter WL4822, WL6022 models ONLY W -One Inch Washable Filter WL4822, WL6022 models ONLY P -Two Inch Pleated Filter WL4822, WL6022 models ONLY NOTE: All vent options are without exhaust capability. May require separate field supplied barometric relief in building. Model WL602N is identical to Model WL6023. All references in this manual to WL6023 apply to WL602N also. TABLE 1 ELECTRIC HEAT TABLE Models WL6023A ONLY WL6023B ONLY 240V-1 208V-1 240V-1 208V-1 KW AMPS BTUH AMPS BTUH AMPS BTUH AMPS BTUH 5.0 20.8 17,050 18.1 12,800 ---- -- -- 9.0 ---- -- -- 21.7 30,600 18.7 23,030 10.0 41.6 34,130 36.2 25,600 ---- -- -- WL4822A, WL4822B, WL4823A, WL4823B, WL6022A, WL6022B are not approved for use with electric heat. Manual 2100-351 Page 2 Manual 2100-351 Page 3 FIGURE 1 UNIT DIMENSIONS WL602N, WL6023, WL4823 ONLY MIS-1451 Manual 2100-351 Page 4 FIGURE 2 UNIT DIMENSIONS WL6022, WL4822 ONLY MIS-1452 TABLE 2 ELECTRICAL SPECIFICATIONS Manual 2100-351 Page 5 Mode l SINGL E CIRCUI T DUA L CIRCUI T Rate d Volts & Phas e No . Fiel d Powe r Circuit s • Minimu m Circui t Ampacit y • Maximu m Externa l Fus e o r Ckt . Breake r • Fiel d Powe r Wir e Siz e • Groun d Wir e Siz e • Minimu m Circui t Ampacit y • Maximu m Externa l Fus e o r BreakerCkt . • Fiel d Powe r Wir e Siz Groun d Wir Siz CK T A CK T B CK T A CK T B CK T A CK T B CK T A CK T B WL4822A00 , A0 Z 230/208- 1 1 3 8 5 0 8 1 0 N/ A N/ A N/ A N/ A N/ A N/ N/ N/ WL4822B00 , B0 Z 230/208- 3 1 2 6 3 5 8 1 0 N/ A N/ A N/ A N/ A N/ A N/ N/ N/ WL4823A00 , A0 Z 230/208- 1 1 3 8 5 0 8 1 0 N/ A N/ A N/ A N/ A N/ A N/ N/ N/ WL4823B00 , B0 Z 230/208- 3 1 2 6 3 5 8 1 0 N/ A N/ A N/ A N/ A N/ A N/ N/ N/ WL6022A00 , A0 Z A0 5 A1 0 230/208- 1 1 1 1 4 4 4 4 5 5 6 0 6 0 6 0 8 8 6 1 0 1 0 1 0 N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ N/ N/ N/ N/ N/ N/ N/ N/ WL6022B00 , B0 Z B0 9 230/208- 3 1 1 3 2 3 4 4 5 4 5 8 8 1 0 1 0 N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ N/ N/ N/ N/ N/ WL6023A00 , A0 Z A0 5 A1 0 230/208- 1 1 1 1 4 4 4 4 5 5 6 0 6 0 6 0 8 8 6 1 0 1 0 1 0 N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ N/ N/ N/ N/ N/ N/ N/ N/ WL6023B00 , B0 Z B0 9 230/208- 3 1 1 3 2 3 4 4 5 4 5 8 8 1 0 1 0 N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ N/ N/ N/ N/ N/ WL602NA00 , A0 Z A0 5 A1 0 230/208- 1 1 1 1 4 4 4 4 5 5 6 0 6 0 6 0 8 8 6 1 0 1 0 1 0 N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ N/ N/ N/ N/ N/ N/ N/ N/ WL602NB00 , B0 Z B0 9 230/208- 3 1 1 3 2 3 4 4 5 4 5 8 8 1 0 1 0 N/A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ N/ N/ N/ N/ N/ . Maximum size of the time delay fuse or . Based on 75° C copper wire. All Wiring must conform to NEC and . These “ minimum Circuit Ampacity” values are to be used for sizing Refer to the National Electric Code (latest revision), CAUTION: When more than one field power conductor circuit is run through Pay special attention to note 310 regarding Ampacity SHIPPING DAMAGE Upon receipt of equipment, the carton should be checked for external signs of shipping damage. If damage is found, the receiving party must contact the last carrier immediately, preferably in writing, requesting inspection by the carrier’s agent. GENERAL The equipment covered in this manual is to be installed by trained, experienced service and installation technicians. The refrigerant system is completely assembled and charged. All internal wiring is complete. The unit is designed for use with or without duct work. Flanges are provided for attaching the supply and return ducts. These instructions explain the recommended method to install the air cooled self-contained unit and the electrical wiring connections to the unit. While these instructions are intended as a general recommended guide, they do not supersede any national and/or local codes in any way. Authorities having jurisdiction should be consulted before the installation is made. See Page 1 for information on codes and standards. Size of unit for a proposed installation should be based on heat loss calculation made according to methods of Air Conditioning Contractors of America (ACCA). The air duct should be installed in accordance with the Standards...

Questo manuale è adatto anche per i modelli :
Condizionatori - WL4823 (280.08 kb)
Condizionatori - WL6022 (280.08 kb)
Condizionatori - WL602N (280.08 kb)
Condizionatori - WL4822 (280.08 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie