Istruzioni per l'uso Friedrich, Modello 230 VoltsUS12

Produttore : Friedrich
File Size : 1.98 mb
File Nome :
Lingua di insegnamento: enesfr
Vai a scaricare



Facilità d'uso


12 18 D 18-5/83/4 18-5/8 D 19-3/41-3/4 19-3/4 D 22 4 Place the plastic grille FIG. 9 3 Fasten the 4 washer screws to secure the grille to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges. or Fasten the screws FIG. 10 6 Remove the backing from the support blocks and attach them to the inside of the wall sleeve as shown FIG 9. Slide the baffle into slots of the support blocks. Baffle Front Support Block (7 5/16") Wall Wall Sleeve FIG. 13 7 Install the new unit into the wall sleeve. Features and Installation 14 PROCEDURE B To assemble trim, snap the tab of each piece into the slot of the other piece as shown below. Slide trim over the front of the air conditioner until trim is flush with sleeve as shown below. Wall Trim (2 ea) FIG. 14 Features and Installation • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit. • When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils. • Make sure air conditioner does not fall during removal. CAUTION 15 PROCEDURE C 1 Redirect the louvers at the back of the wall sleeve to 60° angle as shown in the FIG 15. The use of pliers is recommended. Rear Louvers (Top View) 60° 7 13/16 " 60° FIG. 15 If the wall sleeve already has a rear grille, skip to step 4. If the wall sleeve does not have a rear grille or louvered panel, install the plastic grille from the kit. Cut the plastic grille to 26-1/2" wide and 15-1/2" high or to the sleeve dimensions. Place the plastic grille to the inside of the wall sleeve at the rear flange. Place the plastic grille FIG. 16 3 Fasten the 4 washer screws to secure the grille to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges. or Fasten the screws FIG. 17 4 Remove the backing from the Horizontal Insulation strip 13/8" x 13/8" x 273/16" and attach that to the inside bottom of the sleeve as shown below. Remove the backing from the Around Insulation strip 13/8" x 13/8" x 611/2" and attach that to the inside front of the sleeve as shown below. Around Insulation Horizontal Insulation FIG. 18 5 If the depth of your existing sleeve is less than or equal to 18”, skip to step 7. Otherwise, cut the baffles and the support blocks according to Length "A" in the table below. Depth"D" of the existing wall sleeve (inches) Length "A" (inches) A A Support Block Baffle FIG. 19 18 D 18-5/83/4 18-5/8 D 19-3/41-3/4 19-3/4 D 22 4 6 Remove the backing from the support blocks and attach them to the inside of the wall sleeve as shown FIG 20. Slide the baffle into slots of the support blocks Baffle Front Support Block (7 13/16") Wall Wall Sleeve FIG. 20 2 Features and Installation 16 9 To assemble trim, snap the tab of each piece PROCEDURE C into the slot of the other piece as shown below. Remove the backing from the 13" shim strips Slide trim over the front of the air conditioner and attach them as shown below in Fig. 22. until trim is flush with sleeve as shown below. The higher portion of shim is to be placed in front of the rib on the base of wall sleeve. Install the new unit into the wall sleeve8 Wall Trim (2 ea) FIG. 23 FIG. 21 1" high 3/4" High Shim (2EA) 6" 6" FIG. 22 Features and Installation • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit. • When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils. • Make sure air conditioner does not fall during removal. CAUTION 17 Before you call for service... Troubleshooting Tips Save Time and Money! Review the chart below first and you may not need to call for service. Normal Operation • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency. • You may hear the thermostat click when the compressor cycles on and off. • Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit. • The fan may run even when the compressor does not. Abnormal Operation Problem Possible Causes What To Do Air conditioner does not start The air conditioner is unplugged. The fuse is blown/circuit breaker is tripped. Power failure. • Make sure the air conditioner plug is pushed compl...

Questo manuale è adatto anche per i modelli :
Condizionatori - 115 Volts US08 (1.98 mb)
Condizionatori - 230 Volts US10 (1.98 mb)
Condizionatori - 230 VoltsUE10 (1.98 mb)
Condizionatori - 230 VoltsUE12 (1.98 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie