Log:
valutazioni - 3, GPA: 4.7 ( )

Istruzioni per l'uso Friedrich, Modello HACW12DB - HCCW12DB

Produttore : Friedrich
File Size : 947.49 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


2.36”) • Height limit: below 25ft. • Maximum tubing length: below 50ft. Tubing length over 25ft. 9/12 Btuh (Single or Multi-Zone) • Charge additional refrigerant amount, additional refrigerant amount =0.44oz./ft.>25’. • Capacity drops slightly. More than 12” More than 2” More than 16” More than 4” More than 10” INSTALLATION (Single Zone Shown) NOTE: Always check superheat and subcooling of system. (22.72”) 9/12 Btuh (23.94”) 18/24 Btuh (8.86”) 9 Btuh( 11.02”) 12 Btuh(14.25”) 18/24 Btuh Distance between the unit(s) and ceiling should be more than 2” Clearance in front of unit(s) should be no less than 10’ Distance between the unit(s) and the wall should be more than 6” Fasten the unit(s) on the lower hook of wall plate Fasten the unit(s) on the upper hook of wall plate Distance between the unit(s) and the wall should be more than 6” Wall plate Patch Outgoing tubing (bottom) Wall cap Connecting wire Through the wall tubing (O.D. 2.36”) • Height limit: below 25ft. • Maximum tubing length: below 50ft. Tubing length over 25ft. 9/12 Btuh (Single or Multi-Zone) • Charge additional refrigerant amount, Parts of Indoor Unit No. Part Qty 1 Remote Control 1/unit 2 Remote Control Fixture 1/unit 3 Batteries 'LR03' (AAA) 2/unit 4 Manual 1 Parts of Outdoor Unit No. Part Qty 1 9/12 Btuh 4 Rubber Cushion 2 18/24 Btuh 4 Rubber Cushion 3 Drain Pipe 1 DETERMINATION OF INSTALLING POSITION Install the Air Conditioner(s) by taking into account the following points, upon the customer’s consent. • Make sure that the indoor unit(s) are installed high enough, over 6 feet, (beyond reach of young children). Indoor Unit • Do not install the unit(s) near a heat source. • Be sure that air outlet and inlet are not obstructed. • Be sure all clearances are as specified in the above figure (front, upper, left and right of the unit(s)). • Allow convenient drainage and piping connection with the outdoor unit. • Avoid installing the unit(s) in direct sunlight. • Install the unit(s) on walls that can support their weight. ! CAUTION ! • Be sure chosen location can properly support the weight of the unit(s) and will provide adequate damping of vibration and noise. Outdoor Unit • Insure chosen location can provide adequate drainage and good ventilation. • Do not install in an area with flammable or corrosive vapors. Avoid salty air or sulfuric gas areas. • Be sure all clearances are specified in the above figure (front, upper, left, right and rear of the unit) and also open on more than two sides. • Be sure hot exhaust and noise does not bother the customer or their neighbors. • Do not allow hot exhaust to blow directly on pets and plants. ! CAUTION ! • Read this installation manual thoroughly before installing the air conditioner(s) for proper installation. • All field wiring must be installed by a licensed electrician and must comply with all national and local codes. • All field piping must be installed by a licensed refrigeration technician and must comply with all national and local c...

Questo manuale è adatto anche per i modelli :
Condizionatori - HACM09DB - HCCM99DB (947.49 kb)
Condizionatori - HACM12DB - HCCM22DB (947.49 kb)
Condizionatori - HACM12DB - HCCM22DB (947.49 kb)
Condizionatori - HACM09DB - HCCM99DB (947.49 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie