Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Admiral, Modello AAW-18CR1FHUE

Produttore : Admiral
File Size : 5.16 mb
File Nome :

Lingua di insegnamento: enes

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


• A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired. • The power supply cord contains no use serviceable parts. Opening the tamper-resistant case voids all warranty and performance claims. INSTALLATION INSTRUCTIONS Unpack the Air Conditioner EXCESSIVE WEIGHT HAZARD Use two or more people to move and install air conditioner. Failure to do so can result in back or other injury. Remove packaging materials • Remove and properly dispose of packaging materials. Remove tape and glue residue from surfaces before turning on the air conditioner. Rub a small amount of liquid dish soap over the adhesive with your fingers. Wipe with warm water and dry. • Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue. These products can damage the surface of your air conditioner. • Handle air conditioner with care. 5 WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 8 ELECTRICAL SPECIFICATIONS 1. All wiring must comply with local and national electrical codes and must be installed by a licensed electrician. If you have any questions regarding the following instructions, contact a licensed electrician. 2. Check available power supply and resolve any wiring problems BEFORE installing and operating this unit. 3. For your safety and protection, this unit is grounded through the power cord when plugged into a matching wall outlet. If you are not sure whether your wall outlet is properly grounded, please consult a licensed electrician. 4. The wall outlet (3-pin) must match the plug (3-pin) on the power cord supplied with the unit. DO NOT use plug adapters or extension cords. See (Table 1) for receptacle and fuse information. 5. The rating plate on the unit contains electrical and other technical data. The rating plate is located on the front of the base pan. Make sure to use the correct power supply according to the rating plate of your air conditioner. Electric Shock Hazard ! If the air conditioner has a serial plate rating of 115 volts and up to and including 7.5 amps, the unit maybe on a fuse or circuit breaker with other devices. However, the maximum amps on all devices for that fuse or circuit breaker can not exceed the amps of the fuse for the circuit breaker. If the air conditioner has a serial plate rating of 115 volts and greater than 7.5 amps it must have its own fuse or circuit breaker, and no other device or unit should be operated on the fuse or circuit breaker. If the air conditioner has a serial plate rating of 230 volts, it must have its own fuse or circuit breaker, and no other device or unit should be operated on the fuse or circuit breaker. To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing. RECEPTACLE AND FUSE TYPES COOLING CAPACITY 8K-15K 18K 22K-24K RATED VOLTS 125 250 250 AMPS 15 15 20 WALL OUTLET FUSE SIZE 15 15 20 Table 1 Note:8K-15K including AAW-08CM1FHUE AAW-...

Questo manuale è adatto anche per i modelli :
Condizionatori - AAW-08CM1FHUE (5.16 mb)
Condizionatori - AAW-22CR1FHUE (5.16 mb)
Condizionatori - AAW-24CM1FHUE (5.16 mb)
Condizionatori - AAW-24CR1FHUE (5.16 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie