Log:
valutazioni - 2, GPA: 4 ( )

Istruzioni per l'uso Heat Controller, Modello RAD-123H

Produttore : Heat Controller
File Size : 7.03 mb
File Nome : comfort-aire-rads-81h.pdf
Lingua di insegnamento: en
Vai a scaricare



da questo dispositivo ha anche altre istruzioni :

Facilità d'uso


It may cause an electric shock 3 Heat Controller, Inc. Room Air Conditioner with R-410A Owner’s Manual IMPORTANTSAFETYINSTRUCTIONSBesuretheelectricalserviceisadequateforthemodelyouhavechosen.Thisinformationcanbefoundontheserialplate,whichislocatedonthesideofthecabinetandbehindthegrille.Besuretheairconditionerisproperlygrounded.Tominimizeshockandfirehazards,propergroundingisimportant.Thepowercordisequippedwithathree-pronggroundingplugforprotectionagainstshockhazards.Yourairconditionermustbeusedinaproperlygroundedwallreceptacle.Ifthewallreceptacleyouintendtouseisnotadequatelygroundedorprotectedbyatimedelayfuseorcircuitbreaker,haveaqualifiedelectricianinstalltheproperreceptacle.Ensurethereceptacleisaccessibleaftertheunitinstallation.Donotrunairconditionerwithoutsideprotectivecoverinplace.Thiscouldresultinmechanicaldamagewithintheairconditioner.Donotuseanextensioncordoranadapterplug. WARNINGForyoursafetyDonotstoreorusegasolineorotherflammablevaporsandliquidsinthevicinityofthisoranyotherappliance.Avoidfirehazardorelectricshock.Donotuseanextensioncordoranadaptorplug.Donotremoveanyprongfromthepowercord. WARNINGElectricalInformation NOTEForsomemodels,thepowersupplycordwiththisairconditionercontainsacurrentdetectiondevicedesignedtoreducetheriskoffire.PleaserefertothesectionOperationofCurrentDevicefordetails.Intheeventthatthepowersupplycordisdamaged,itcannotberepaired-itmustbereplacedwithacordfromtheProductManufacturer. , , Donot,underanycircumstances,cut,remove,orbypassthegroundingprong.Powersupplycordwith3-pronggroundingplugandcurrentdetectiondeviceOperationofCurrentDevice(Applicabletotheunitadoptscurrentdetectiondeviceonly)Thepowersupplycordcontainsacurrentdevicethatsensesdamagetothepowercord.Totestyourpowersupplycorddothefollowing:1.PlugintheAirConditioner.2.ThepowersupplycordwillhaveTWObuttonsontheplughead.PresstheTESTbutton,youwillnoticeaclickastheRESETbuttonpopsout.3.PresstheRESETbutton,againyouwillnoticeaclickasthebuttonengages.4.Thepowersupplycordisnowsupplyingelectricitytotheunit.(Onsomeproductsthisitalsoindicatedbyalightontheplughead.)Donotusethisdevicetoturntheunitonoroff.AlwaysmakesuretheRESETbuttonispushedinforcorrectoperation.ThepowersupplymustbereplacedifitfailsresetwheneithertheTESTbuttonispushed,oritcannotbereset.Anewonecanbeobtainedfromtheproductmanufacturer.Ifpowersupplycordisdamaged,itcannotberepaired.ItMUSTbereplacedbyone NOTES: obtainedfromtheproductmanufacturer. 4 Please refer to the section “Operation of Current Device” for details. Cooling operation Outdoor Temp: 64.4-109.4°F (18-43°C) (T1 Environment) 69.8-125.6°F (21-52°C) (T3 Environment) Indoor Temp: 62.6-89.6°F (17-32°C) (T1 Environment) 62.6-89.6°F (17-32°C) (T3 Environment) Heat operation Outdoor Temp: 23.0-75.2°F (-5-24°C) (T1 Environment) 19.4-75.2°F (-7-24°C) (T3 Environment) Indoor Temp: 32.0-80.6°F (0-27°C) (T1 Environment) 32.0-86.0°F (0-30°C) (T3 Environment) 4 Owner’s Manual Room Air Conditioner with R-410A Heat Controller, Inc. Unit may vibrate and make noise because of poor wall or window construction or incorrect installation. Pinging or Swishing Droplets of water hitting condenser during normal operation may cause pinging or swishing sounds. Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation. NOTE: Clear Air and/or Follow Me features only apply to certain models. Your control panel may or may not have there features and display lights. Check the actual unit you purchased to determine if these options apply. 5 Heat Controller, Inc. Room Air Conditioner with R-410A Owner’s Manual TO CHANGE TEMPERATURE SETTING: Press or hold either Left (<) or Right (>) Temp/Timer buttons until the desired temperature is seen on the display. This temperature will be automatically maintained anywhere between 62°F (17°C) and 86°F (30°C). If you want the display to read the actual room temperature, see “To Operate on Fan Only” section. The fan speed button is used to select the Fan Speed in four steps: Auto, Low, Med or High. Each time the button is pressed, the fan speed mode is shifted. When the unit is operating in Dry mode, the fan speed is automatically controlled at Low fan speed. 6 Owner’s Manual Room Air Conditioner with R-410A Heat Controller, Inc. To choose operating mode, press the Mode button. Each time you press the button, a mode is selected in a sequence that goes from Auto, Cool, Dry and Fan. The indicator light beside will illuminate and remain on once the mode is selected. TO SELECT THE OPERATING MODE: When you set the air conditioner in AUTO mode, it will automatically selec...

Questo manuale è adatto anche per i modelli :
Condizionatori - RADS-81H (7.03 mb)
Condizionatori - RADS-101H (7.03 mb)
Condizionatori - RADS-121H (7.03 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie