Istruzioni per l'uso Samsung, Modello AQ12UGFN

Produttore : Samsung
File Size : 4.68 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


300mm or more 125mm or more 125mm or more Wrap the refrigerant pipes and the drain hose with the absorbent pad and vinyl tape. Refer to page 38 for further details. You can select the direction of draining (left or right). 'L' m as maximum pipe length and 3 m as minimum pipe length (It will reduce noise and vibration) ' H ' meters maximum total pipe length ' L ' meters maximum total pipe length 600mm minimum 300mm minimum 300mm minimum Model L H ..09/12/18.. 15 7 ..24.. 20 8 600mm minimum Make at least one round: It will reduce noise and vibration . The appearance of the unit may be different from the diagram depending on the model. Space Requirements for Outdoor Unit When installing 1 outdoor unit . Figure Description Top view Side view Air intake Air intake Air outlet Air outlet . , Air flow direction. (Unit : mm) . When the air outlet is towards the wall . When 3 sides of the outdoor unit are blocked by the wall . When the air outlet is opposite the wall 300 or more 300 or more 1500 or more 150 or more 600 or more . The upper part of the outdoor unit and the air outlet is towards the wall . The upper part of the outdoor unit and the air outlet is opposite the wall . When the walls are blocking front and the rear side of the outdoor unit 500 or more 1500 or more 300 or more 300 or more 2000 or more 1500 or more When installing more than 1 outdoor unit (Unit : mm) . When the air outlet is towards the wall . When 3 sides of the outdoor unit are blocked by the wall 300 or more 1500 or more 300 or more 600 or more 600 or more 600 or more Choosing the installation location (Unit : mm) . When the upper part of the outdoor unit and the air outlet is opposite the wall . When the walls are blocking front and the rear side of the outdoor units 300 or more 500 or more 300 or more 1500 or more 600 or more 600 or more . When front and rear side of the outdoor unit is towards the wall 500 or more 300 or more 1500 or more 600 or more 3000 or more 200 or more 3000 or more • If installation is done in inappropriate space, unit may generate sound and cause bad effect on the product. • Installation must be done in level and in a place where vibration will not cause any effect. Accessories The following accessories are supplied with the air conditioner: • The number of each accessory is indicated in parentheses. Accessories in the indoor unit case Installation Plate (1) Remote controller (1) Batteries for Remote controller (2) User’s & Installation Manual (1) Accessories in the outdoor unit case 5-wire Assembly Cable (1) Drain Plug (1) Rubber Leg (4) • The flare nuts are attached to the end of each pipe of an evaporator or a service port. Use the nuts when connecting the pipes. • The 5-wire assembly cable is optional. If it is not supplied, use the standard cable. • The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture below. Optional accessories The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air conditioner. Insulated Assembly Pipe, O6.35mm (1) Insulated Assembly Pipe, O9.52mm (1) ..09.. Insulated Assembly Pipe, O12.70mm (1) ..12/18.. Insulated Assembly Pipe, O15.88mm (1) ..24.. PE T3 Foam Tube Insulation (1) Vinyl Tapes (2) Drain Plug (1) Rubber Legs (4) Pipe Clamps A (3) Pipe Clamps B (3) Cement Nails (6) M4 x 25 Tapped Screws (6) Drain Hose, length 2m (1) Putty 100g (1) • If these accessories are supplied, they will be in the accessory box. Tools required for installation General Tools • Vacuum Pump(Backward flowing prevention) • Manifold Gauge • Stud Finder • Torque Wrench • Pipe Cutter • Reamer • Pipe Bender • Spirit Level • Screw Driver • Spanner • Drill • L Wrench • Measuring Tape Tools for test operations • Thermometer • Resistance Meter • Electroscope Fixing the installation plate You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit. When facing the wall, the pipe and cable can be connected from the: • Right (A) • Left (B) • Underside_right (C) • Rear_right or left (D) . Direction of pipe BADCD 1. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly downwards. (Unit : mm) BADC Model A B C D ..09/12.. 27 120 68 27 ..18/24.. 34 140 68 34 Pipe hole (O65mm) • Make sure to drill only one hole after choosing the direction of the pipe. Fixing the installation plate 2. Fix the indoor unit. If you fix the indoor unit on a wall (1) Fix the installation plate to the wall giving attention to the weight of the indoor unit. Plastic Anchor • If you mount the plate to a concrete wall using plastic anchors, make sure t...

Questo manuale è adatto anche per i modelli :
Condizionatori - AQ09TSBNEUR (4.68 mb)
Condizionatori - AQ09TSBXEUR (4.68 mb)
Condizionatori - AQ09UGFN (4.68 mb)
Condizionatori - AQ09UGFX (4.68 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie