You can set the period of time from 30 minutes to 24 hours. Off 1 To set the operating time, press the button one or more times until the required time is displayed. Possible time is between 0.5 hour and 24 hours inclusive. 2 Press the fewnccci (Set/Cancel) button to complete the setting. Result: ♦ The remaining time is displayed. ♦ Blinking of the timer indicator stops. ♦ The air conditioner will switch off automatically when the counter displayed on the remote control reaches the set time and disappears the Off timer setting. Example If you would like to turn the air conditioner on after 2 hours and to operate it for 2 hours: On 1. Press the button until ‘2.0 Hr' is displayed. 2. Press the 11^ (Set/Cancel) button. 3. Press the button until ‘4.0 Hr' is displayed. 4. Press the aCCCCcc (Set/Cancel) button. C_J N®W& You can see or change the setting mode and/or the temperature by pressing the r's button or the C® C ®) button after setting the Off timer. To Cancel the Off Timer Timer Press the s*cccaC (Set/Cancel) button. ^--J Timer..... ♦ If you press the (-a button when the On Timer is set, the On Timer is also cancelled. 1 1 13. n UHr CD CD On Off Tmer Timer^A CZ> ENGLISH Setting the Sleep Timer The Sleep Timer can be used when you are cooling your room to switch the air conditioner off automatically after a period of 6 hours. Note If you wish to switch the unit off at a specific time, refer to page 19. 1 Make sure that you have selected the COOL mode. 2 Press the *jC button. a Result: ♦ The indoor unit beeps. ♦ The air conditioner will be controlled as indicated in the illustrations below. Cooling The desired temperature is increased by 1°C every hour. When it has been increased by 2°C (after 2 hours), the temperature is maintained for four hours. 2"C 1“C Set 1 ' TEMP. St tin 1 hr 2hr 6hr art Stop ne time To Cancel the Sleep Timer * On On Timer Tmer Set/it».. CD CD CD] -w CD If you no longer wish to use the Sleep Timer that you have set, you can cancel it at any time. Press the m^CcC button. Result: ♦ The indoor unit beeps. ♦ The c'CC is no longer displayed. ♦ The air conditioner operates normally. e-20 Operating Recommendation Here is a recommendation that you should follow when using your air conditioner. Topic Recommendation Power failure If a power failure occurs when the air conditioner is operating, the unit is switched off. When the power returns, the air conditioner starts up again automatically. e-21 ENGLISH Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used. If the air conditioner is used at... Then... High temperatures The automatic protection feature may be triggered and the air conditioner stopped. Low temperatures A water leak or some other malfunction may occur if the heat exchanger freezes. High humidity levels Water may condense on and drip from the surface of the indoor unit if it is used for long periods. Mode Outdoor Temperature Indoor Temperature Indoor Humidity Cooling 21°C to 43°C approx. 18°C to 32°C approx. 80% or less Drying 18°C to 43°C approx. 18°C to 32°C approx. - # If the cooling operation is used at over 33°C(indoor temperature), it does not cool at its full capacity. Operating Your Air Conditioner Without the Remote Control Your air conditioner can be operated directly from the indoor unit if the remote control is lost or broken. 1 Slide the lower front grille down. 2 To switch the air conditioner on, press the On/Off switch on the right side of the indoor unit. Result: ♦ The Operation indicator on the indoor unit comes on. ♦ The indoor unit beeps. ♦ The air conditioner starts up in the most suitable mode for the room temperature: Room Temperature Operating Mode 21°C or above Cool 3 To switch the air conditioner off, press the On/Off switch again. Note Even if the air conditioner has been switched on via the On/Off switch, operations can still be controlled using the remote control as usual. e-22 Solving Common Problems Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary call. Problem Explanation/Solution The air conditioner does not operate at all ♦ Check that the breaker used for the air conditioner is switched on. ♦ Check that the operation indicator on the indoor unit is on; if necessary press the @ (On/Off) button on the remote control. ♦ Check whether the Timer indicator on the indoor unit is switched on. If so: - Wait until the switch-on time is reached and the air conditioner starts up automatically - Cancel the timer (see pages 18 and 19 for further details) The air conditioner does not operate with the remote control ♦ Check that there are no obstacles between you and the indoor unit. ♦ Check the remote control batteries. ♦ Check that you are close enough to the indoor unit (seven...

Questo manuale è adatto anche per i modelli :
Condizionatori - AS09P2GE1/ABS (6.09 mb)
Condizionatori - AS12P4GE1/ABS (6.09 mb)
Condizionatori - AS18P0GEA1ABS (6.09 mb)
Condizionatori - AS24P6GEA1ABS (6.09 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie