Log:
valutazioni - 0, GPA: 0 ( )

Istruzioni per l'uso LG, Modello PDRCUDB0S

Produttore : LG
File Size : 3.77 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Installation Instruction Installation Instruction Installer Setting - Test Run Mode The Test Run Mode is to check the installation status of the product. The temperature will not be controlled during trial operation. Instead the product will operate in several modes such as cooling, strong wind, comp-on. 1 1 The test run mode is to check the installation status of the product. The temperature will not be controlled. Instead the product will operate in several modes such as cooling, strong wind, comp-on. 2 If you want to do the test run mode, press the button and then select the button. 3 Then the product will begin the test run mode and the display will be like the left picture. 4 The test run mode will continue for 18 minute. After finishing this operation, the product will go into off mode. 5 If you wan to cancel the test run mode during the process, press the button. * This function might not be available for multi product like Multi V system. Installer Setting - Setting the Zone Type If you Install damper controller on the indoor unit, you must set the zone type by changing slide switch of wired remote controller If you set the zone type incorrectly, the product may malfunction especially in zone control. This function must carried out by a certificated-technician CAUTION Group control S/W 2 S/W GR S/W 1 S/W Ceiling height / E.S.P Zone type selection Product selection 1. C/O Product • On installing, don't impact to the PCB and LCD display • Don't remove the caution label. • Use the specified screw • On installing, turn off the main power *E.S.P: External Static Pressure 2. H/P Product 1. Zone New 1. Low / Low 2. Standard / High 3. High / High 1. Master 2. Slave 2. Zone Old 1 2 1 2 1 2 12 3 1 1 Open the protection cap on the back-cover of the remote controller. 2 2 Change the slide switch from 2 to 1 for setting zone type new. * If you connect 2 remote controllers with one indoor unit, you must change the slide switch of both remote controllers 10 Deluxe wired remote controller Installation Instruction Installer Setting - Setting the Cental Control Address Group No. Indoor No. Note : The remote controller displays 'HL' if central controller has locked the remote controller . 1 Press the button. 2 Press the button. Press the button to change the group number. Press the button to change the indoor unit number. In the figure on the left, the number of the central control address group is "2." and the number of the indoor unit is "5." 3 If you press the button more time.the address value will be set. * If you connect the indoor unit to the central controller, you should set the network address of the indoor unit so that the central controller could recognize it. * The central control address is composed of the group number and the indoor-unit number. Installer Setting - Setting the Zone Number Installed Zone Number is to set the number of installed zones. It’s possible to control only in zone new type CAUTION If you set zone number incorrectly, the product may malfunction especially in zone control. This function must carried out by a certificated-technician Zone Number 1 Press the button displayed only in turn-on mode) 2 Press the button to increase/decrease the installed number of Zone . You can select the number between 2 and 4. 3 Press the button to confirm ENGLISH Owner’s & Installation Manual 11 Installation Instruction Installer Setting - ESP Function E.S.P function is setting the volume of each air flow. It is for the convenience of installation. It is recommended that you should not use this function while using the wireless remote controller. If you set ESP incorrectly, the air conditioner may malfunction. This setting must be carried out by a certificated-technician. CAUTION 100 unit 10 unit 1 Press the button. 2 Press the button. 3 Set the volume of each air flow ( LoMedHi) by using the button. Press the button to select the air flow. (The value of E.S.P could be adjusted from 1 to 255.) (The figure on the left shows when the strong wind’s ESP value has been set to 212.) 4 If you press the button one more time, the E.S.P value will be set and the setting mode will be unset. * Slo and Po setting is not available for some products. * Because the EPS value is already appropriately set when manufactured from the factory, it is recommended that you do not change the ESP value. 12 Deluxe wired remote controller Owner's Instruction Owner's Instruction Cooling Mode What is the three-minute delay function? The function to protect the compressor delays the output of cool air when operating instantly after interrupting the cooling mode . Cooling mode restarts after 3 minutes when the compressor starts to operate. A click of the button will increase the expected temperature by 1°C A click of the button will decrease the expected temperature by 1°C. AUTO 1 Cooling mode will begin if you press the button. 3 Press the button and choose one of the functions among , , , and if you want another operation mode duri...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie