Istruzioni per l'uso Bryant, Modello 517G

Produttore : Bryant
File Size : 645.28 kb
File Nome : pds517e.42.2b.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Single-phase 15- or 20-KW heaters are wired for dual-circuit operation. The optional single-circuit kit may be field-installed in units with a 15- or 20-KW single-phase fused heater for single-circuit operation. tfCB = circuit breakers. ++Used for right-angle refrigerant connections to the coil (or optional 510B Coil). ***Wire sizes and lengths are based on copper conductor at 86°F (30°C) ambient temperature and ampacity shown in table. Insulation must be 90°C on conductor used between the disconnect switch and the heater and at least 75°C on the conductor used between the disconnect and the service panel. If other than copper conductor is used, or if ambient temperature is above 86°F, determine wire size for ampacity shown and the National Electric Code. Wire lengths shown are measured one way along the wire path between the disconnect and service panel for minimum 2% voltage drop. tttUse piston size shipped with outdoor unit. SPECIFICATIONS—UNITS WITH ELECTRIC HEATER MODEL 517G SIZE N060015 I P060018 I N060020 RATINGS & PERFORMANCE Nominal Capacity (Btuh)* 60,000 60,000 60,000 Nominal Airflow (Cfm)f 2000 2000 2000 Electric Heating Output (KW)+ 15.0 18.0 20.0 Electric Heating Capacity (MBtuh)+ 38.5/47.0 46.1/56.4 51.3/62.7 ELECTRICAL Unit Volts—Phase (60 Hz) 208/230-1 208/230-3 208/230-1 Operating Voltage Range 187-253 187-253 187-253 Internal Circuit Protection** Fuses CB++ None Fuses CB++ Single-Circuit Operation Full Load Amps 59.6/65.6 _ 43.2/47.2 77.6/85.6 _ Minimum Ampacity for Wire Sizing 74.5/82 — 54/59 97/107 — Minimum Wire Size*** 6/4 — 6/6 3/2 — . Maximum Wire Length (Ft)*** 77/122 — 130/132 118/149 — Maximum Fuse Size (Amps) 80/90 — 60/60 100/110 — Dual-Circuit Operation Full Load Amps L1 & L2 41.6/45.6 _ 41.6/45.6 L3&L4 18/20 — 36/40 Minimum Ampacity for Wire Sizing L1 & L2 52/57 _ 52/57 L3 & L4 22.5/25 — 45/50 Minimum Wire Size*** L1 & L2 6/6 — 6/6 L3&L4 10/10 — 8/6 Maximum Wire Length (Ft)*** L1 & L2 110/111 — 110/111 L3&L4 . 102/102 — 81/126 Maximum Fuse Size (Amps) L1 & L2 60/60 — 60/60 L3&L4 25/25 — 45/50 Control Transformer—24V (VA) 60 60 60 INDOOR COIL Rows & Fins Per Inch 4 & 12 Height x Width (In.) 32.5x22.8 Face Area (Sq Ft) 5.1 R-22 Refrigerant Metering Device Check-Flo-Rater Piston ID Numberttt 96 Condensate Drain Connection 3/4 MPT INDOOR BLOWER & MOTOR Wheel Diameter x Width (In.) 11x9 Filter Size—Cleanable (In.) 20 x 25 x 1 Blower Motor HP 3/4 Blower Motor Speeds & Type 3 & DD (PSC) Full Load Amps 5.6 OPTIONAL EQUIPMENT (P/N’S) Liquid-Line Swivel Ell (3/8)++ P651-1066 Vapor-Line Swivel Ell (3/4)++ P651-1068 Single-Circuit Kit** 301820-4001 I - I 301820-4001 *See condensing unit or heat pump outdoor section PDS for cooling and/or heating capacity ratings with 517G Fan Coils. fSee air delivery table in this PDS. +KW values shown are nominal rated heater outputs at 240V and do not include blower motor heat. Capacity values shown are calculated using KW outputs at 208V/230V. **Single-phase 10-, 15-, 20-KW electric heaters have the internal circuit protection options shown. Single-phase 15-or 20-KW heaters are wired for dualcircuit operation. The optional single-circuit kit may be field-installed in units with a 15- or 20-KW single-phase fused heater for single-circuit operation. tfCB = circuit breakers. ++Used for right-angle refrigerant connections to the coil (or optional 510B Coil). ***Wire sizes and lengths are based on copper conductor at 86°F (30°C) ambient temperature and ampacity shown in table. Insulation must be 90°C on conductor used between the disconnect switch and the heater and at least 75°C on the conductor used between the disconnect and the service panel. If other than copper conductor is used, or if ambient temperature is above 86°F, determine wire size from ampacity shown and the National Electrical Code. Wire lengths shown are measured one way along the wire path between the disconnect and service panel for minimum 2% voltage drop. tttUse piston size shipped with outdoor unit. SSC-78 AIR DELIVERY (Cfm) AT INDICATED EXTERNAL STATIC PRESSURE (With Filter) 517E Size Motor Speed Tap Coil . External Static Pressure —Inches wc 0.1 0.2 0.3 0.4 0.5 0.6 0.7 042 High Dry 1760 1700 1625 1535 1450 1350 1225 (Without Heater) Wet 1690 1625 1545 1455 1355 1260 — Medium Dry 1615 1545 1490 1415 1345 1255 1150 Wet 1545 1495 1435 1365 1275 1185 — Low Dry 1435 1385 1340 1280 1210 1135 1035 Wet 1395 1350 1300 1235 1165 1080 — 042 High Dry 1700 1635 1560 1475 1395 1290 — (With Heater) Wet 1625 1565 1485 1415 1320 1200 — Medium Dry 1565 1505 1450 1385 1305 1215 — Wet 1510 1450 1390 1320 1235 1150 — Low Dry 1410 1360 1315 1250 1180 1100 — Wet 1370 1325 1270 1205 1135 — — 048 High Dry 2075 1995 1910 1830 1745 1655 1550 (Without Heater) Wet 1950 1870 1795 1725 1645 1555 1...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie