Log:
valutazioni - 2, GPA: 4.5 ( )

Istruzioni per l'uso York, Modello AY012MA321

Produttore : York
File Size : 684.12 kb
File Nome : 67b89477-8aa9-47ba-8491-6a73938cd180.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


24.6 25.3 25.0 27.5 30.2 25.5 25.8 25.3 27.5 30.2 26.4 26.3 25.5 27.5 30.1 S.C. 23.0 21.8 18.1 18.4 14.6 24.1 23.4 19.8 20.5 15.7 25.1 25.0 21.6 22.6 16.8 KW 2.8 2.8 2.8 2.9 2.9 2.8 2.9 2.8 2.9 2.9 2.9 2.9 2.9 2.9 3.0 115 T.C. 23.7 24.2 24.0 26.3 28.9 24.5 24.7 24.2 26.3 28.8 25.3 25.1 24.4 26.3 28.6 S.C. 22.2 21.4 17.6 17.9 14.3 23.2 22.6 19.5 20.1 15.4 24.1 23.9 21.4 22.2 16.4 KW 3.1 3.1 3.1 3.1 3.2 3.1 3.1 3.1 3.2 3.2 3.2 3.2 3.2 3.2 3.2 125 T.C. 22.8 23.2 23.0 25.0 27.7 23.5 23.6 23.2 25.1 27.4 24.3 23.9 23.4 25.1 27.1 S.C. 21.4 21.0 17.2 17.4 14.0 22.3 21.9 19.2 19.6 15.0 23.1 22.8 21.3 21.8 16.1 KW 3.3 3.3 3.3 3.4 3.5 3.4 3.4 3.4 3.4 3.5 3.4 3.4 3.4 3.4 3.5 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature. Air Handler Coil T.C. S.C. KW MV12B FC/MC36B 1.01 1.02 0.97 MV12B FC/MC42B 1.02 1.03 0.98 MV12B G4FD036H17T2A 1.01 1.02 0.97 MV12B G4FD046H17T2A 1.02 1.03 0.98 MV16C FC/MC36C 1.02 1.03 0.98 MV16C FC/MC42C 1.02 1.03 0.98 MV16C G4FD036H21T2A 1.02 1.03 0.98 MV16C G4FD042H21T2A 1.02 1.03 0.98 AHP36 — 1.00 1.00 1.00 — FC/MC/PC36 1.00 1.00 1.00 — FC/MC/PC42 1.00 1.00 1.00 — G4FA048S17T2A 1.00 1.00 1.00 — G4FD036H17T2A 1.00 1.00 1.00 — G4FD036H21T2A 1.00 1.00 1.00 — G4FD042H21T2A 1.00 1.00 1.00 — G4FD046H17T2A 1.00 1.00 1.00 — HC30 1.00 1.00 1.00 — UC36 1.00 1.00 1.00 — UC42 1.00 1.00 1.00 Variable Speed Furnace Coil T.C. S.C. KW PV8*A12 FC/MC/PC36A 1.01 1.01 1.01 PV8*B16 FC/MC/PC36B 1.02 1.03 0.98 PV8*C16 FC/MC/PC36C 1.0 1.03 0.98 PV8*C20 FC/MC/PC36C 1.02 1.03 0.94 PV9*A12 FC/MC/PC36A 1.01 1.01 1.01 PV9*B12 FC/MC/PC36B 1.01 1.02 1.01 PV9*C16 FC/MC/PC36C 1.01 1.02 0.97 PV9*C20 FC/MC/PC36C 1.01 1.02 0.97 PV8*B16 FC/MC/PC42B 1.02 1.03 0.98 PV8*C16 FC/MC/PC42C 1.02 1.03 0.94 PV8*C20 FC/MC/PC42C 1.02 1.03 0.94 PV9*B12 FC/MC/PC42B 1.01 1.02 0.97 PV9*C16 FC/MC/PC42C 1.01 1.02 0.97 PV9*C20 FC/MC/PC42C 1.01 1.02 0.97 PV8*B16 G4FA048S17T2A 1.02 1.03 0.98 PV9*B12 G4FA048S17T2A 1.01 1.02 0.97 PV8*B16 G4FD036H17T2A 1.0 1.03 0.98 PV9*B12 G4FD036H17T2A 1.01 1.02 1.01 PV8*C16 G4FD036H21T2A 1.02 1.03 0.98 PV8*C20 G4FD036H21T2A 1.02 1.03 0.94 PV9*C16 G4FD036H21T2A 1.01 1.02 0.97 PV9*C20 G4FD036H21T2A 1.01 1.02 0.97 PV8*C16 G4FD042H21T2A 1.02 1.03 0.94 PV8*C20 G4FD042H21T2A 1.02 1.03 0.94 PV9*C16 G4FD042H21T2A 1.01 1.02 0.97 PV9*C20 G4FD042H21T2A 1.01 1.02 0.97 PV8*B16 G4FD046H17T2A 1.02 1.03 0.98 PV9*B12 G4FD046H17T2A 1.02 1.03 0.98 PV8*A12 HC30 1.01 1.01 1.01 PV9*A12 HC30 1.01 1.01 1.01 Unitary Products Group 246814-YTG-D-0606 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. AY036MA321 INDOOR COIL MODEL NO. G2FD042S21 CONDENSER ENTERING AIR TEMPERATURE ID CFM 1000 1200 1400 ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 65 T.C. 32.8 38.1 37.1 40.4 46.6 35.6 38.7 37.7 41.4 46.9 38.3 39.3 38.4 42.3 47.2 S.C. 32.8 30.6 25.5 25.6 21.0 35.4 33.3 27.6 27.8 22.0 37.5 36.0 29.8 29.9 22.9 KW 2.5 2.5 2.5 2.5 2.6 2.5 2.5 2.5 2.5 2.6 2.5 2.5 2.5 2.5 2.6 75 T.C. 32.0 35.9 35.4 38.5 43.7 34.2 36.6 35.9 39.4 44.1 36.4 37.2 36.4 40.3 44.4 S.C. 32.0 29.6 24.8 24.8 20.5 33.8 32.3 26.9 27.0 21.7 35.6 34.9 29.0 29.2 22.9 KW 2.7 2.7 2.7 2.7 2.8 2.7 2.7 2.7 2.8 2.8 2.7 2.7 2.7 2.8 2.8 85 T.C. 31.2 33.8 33.7 36.6 40.9 32.9 34.5 34.1 37.4 41.3 34.5 35.2 34.5 38.2 41.6 S.C. 30.7 28.6 24.1 23.9 20.0 32.2 31.2 26.2 26.2 21.4 33.6 33.9 28.2 28.5 22.8 KW 2.9 2.9 2.9 3.0 3.0 2.9 2.9 2.9 3.0 3.1 3.0 3.0 2.9 3.0 3.1 95 T.C. 30.4 31.6 32.0 34.7 38.0 31.5 32.3 32.3 35.4 38.4 32.6 33.1 32.5 36.1 38.9 S.C. 29.3 27.6 23.4 23.1 19.5 30.5 30.2 25.4 25.4 21.1 31.7 32.8 27.4 27.7 22.7 KW 3.1 3.1 3.1 3.2 3.3 3.1 3.2 3.1 3.2 3.3 3.2 3.2 3.2 3.2 3.3 105 T.C. 28.7 29.5 29.8 32.5 35.7 29.9 30.4 30.2 33.1 36.1 31.0 31.2 30.5 33.6 36.6 S.C. 27.8 26.5 22.5 22.4 18.6 28.9 28.8 24.4 24.6 20.1 30.0 31.0 26.4 26.8 21.6 KW 3.3 3.3 3.3 3.4 3.5 3.4 3.4 3.3 3.4 3.5 3.4 3.4 3.4 3.5 3.6 115 T.C. 27.1 27.6 27.7 30.4 33.5 28.3 28.5 28.2 30.8 33.9 29.4 29.4 28.6 31.2 34.3 S.C. 26.2 25.4 21.6 21.7 17.7 27.2 27.4 23.5 23.8 19.1 28.3 29.3 25.3 25.9 20.5 KW 3.5 3.5 3.5 3.6 3.7 3.6 3.6 3.5 3.7 3.8 3.6 3.6 3.6 3.7 3.8 125 T.C. 25.4 25.6 25.6 28.2 31.3 26.6 26.6 26.1 28.5 31.7 27.8 27.6 26.7 28.8 32.0 S.C. 24.7 24.3 20.7 21.0 16.8 25.6 25.9 22.5 23.0 18.1 26.6 27.5 24.3 24.9 19.4 KW 3.7 3.7 3.7 3.8 4.0 3.8 3.8 3.7 3.9 4.0 3.9 3.9 3.8 3.9 4.0 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temper...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie