Istruzioni per l'uso GE, Modello 5500

Produttore : GE
File Size : 1.48 mb
File Nome : 500_series_data_manual.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Quick Reference 2500 Series Cooling with Electric Heat MODEL NUMBER COOLING (Btuh) Cooling Watts EER Electric Heat (Btuh) Electric Heater Watts Electric Heat Amps Min. Circuit Protection (Amps) AZ25E07D2* 7100/6900 600/585 11.8/11.8 8600/7100 2550/2090 11.0/10.0 15 AZ25E07D3* 7100/6900 600/585 11.8/11.8 11700/9600 3450/2820 15.0/13.6 20 AZ25E09D2* 9000/8800 785/765 11.5/11.5 8600/7100 2550/2090 11.0/10.0 15 AZ25E09D3* 9000/8800 785/765 11.5/11.5 11700/9600 3450/2820 15.0/13.6 20 AZ25E09D5* 9000/8800 785/765 11.5/11.5 17000/13900 5000/4090 21.7/19.7 30 AZ25E12D2* 11700/11500 1075/1055 10.9/10.9 8600/7100 2550/2090 11.0/10.0 15 AZ25E12D3* 11700/11500 1075/1055 10.9/10.9 11700/9600 3450/2820 15.0/13.6 20 AZ25E12D5* 11700/11500 1075/1055 10.9/10.9 17000/13900 5000/4090 21.7/19.7 30 AZ25E15D2* 14600/14300 1520/1490 9.6/9.6 8600/7100 2550/2090 11.0/10.0 15 AZ25E15D3* 14600/14300 1520/1490 9.6/9.6 11700/9600 3450/2820 15.0/13.6 20 AZ25E15D5* 14600/14300 1520/1490 9.6/9.6 17000/13900 5000/4090 21.7/19.7 30 AZ25E07E3* 7100 600 11.8 8600 2550 9.6 15 AZ25E07E4* 7100 600 11.8 12600 3700 14.0 20 AZ25E09E3* 9000 785 11.5 8600 2550 9.6 15 AZ25E09E4* 9000 785 11.5 12600 3700 14.0 20 AZ25E09E5* 9000 785 11.5 17000 5000 18.9 30 AZ25E12E3* 11700 1075 10.9 8600 2550 9.6 15 AZ25E12E4* 11700 1075 10.9 12600 3700 14.0 20 AZ25E12E5* 11700 1075 10.9 17000 5000 18.9 30 AZ25E15E3* 14600 1520 9.6 8600 2550 9.6 15 AZ25E15E4* 14600 1520 9.6 12600 3700 14.0 20 AZ25E15E5* 14600 1520 9.6 17000 5000 18.9 30 2500 and 3500 Series Control Panel 3500 Series Heat Pump with Backup Resistance Heat MODEL NUMBER COOLING (Btuh) Cooling Watts EER Reverse Cycle Heat (Btuh) COP Electric Heat (Btuh) Electric Heater Watts Electric Heat Amps Min. Circuit Protection (Amps) AZ35H07D2* 7100/6900 600/585 11.8/11.8 6400/6200 3.5/3.5 8600/7100 2550/2090 11.0/10.0 15 AZ35H07D3* 7100/6900 600/585 11.8/11.8 6400/6200 3.5/3.5 11700/9600 3450/2820 15.0/13.6 20 AZ35H09D2* 9000/8800 785/765 11.5/11.5 8400/8200 3.5/3.5 8600/7100 2550/2090 11.0/10.0 15 AZ35H09D3* 9000/8800 785/765 11.5/11.5 8400/8200 3.5/3.5 11700/9600 3450/2820 15.0/13.6 20 AZ35H09D5* 9000/8800 785/765 11.5/11.5 8400/8200 3.5/3.5 17000/13900 5000/4090 21.7/19.7 30 AZ35H12D2* 11700/11500 1075/1055 10.9/10.9 10900/10700 3.3/3.3 8600/7100 2550/2090 11.0/10.0 15 AZ35H12D3* 11700/11500 1075/1055 10.9/10.9 10900/10700 3.3/3.3 11700/9600 3450/2820 15.0/13.6 20 AZ35H12D5* 11700/11500 1075/1055 10.9/10.9 10900/10700 3.3/3.3 17000/13900 5000/4090 21.7/19.7 30 AZ35H15D2* 14600/14300 1520/1490 9.6/9.6 13400/13200 3.1/3.1 8600/7100 2550/2090 11.0/10.0 15 AZ35H15D3* 14600/14300 1520/1490 9.6/9.6 13400/13200 3.1/3.1 11700/9600 3450/2820 15.0/13.6 20 AZ35H15D5* 14600/14300 1520/1490 9.6/9.6 13400/13200 3.1/3.1 17000/13900 5000/4090 21.7/14.7 30 AZ35H07E3* 7100 600 11.8 6400 3.5 8600 2550 9.6 15 AZ35H07E4* 7100 600 11.8 6400 3.5 12600 3700 14.0 20 AZ35H09E3* 9000 785 11.5 8400 3.5 8600 2550 9.6 15 AZ35H09E4* 9000 785 11.5 8400 3.5 12600 3700 14.0 20 AZ35H09E5* 9000 785 11.5 8400 3.5 17000 5000 18.9 30 AZ35H12E3* 11700 1075 10.9 10900 3.3 8600 2550 9.6 15 AZ35H12E4* 11700 1075 10.9 10900 3.3 12600 3700 14.0 20 AZ35H12E5* 11700 1075 10.9 10900 3.3 17000 5000 18.9 30 AZ35H15E3* 14600 1520 9.6 13400 3.1 8600 2550 9.6 15 AZ35H15E4* 14600 1520 9.6 13400 3.1 12600 3700 14.0 20 AZ35H15E5* 14600 1520 9.6 13400 3.1 17000 5000 18.9 30 LEGEND All Units are 60 hertz single phase. COP – Coefficient of Performance Dual rated 230/208 volt units are shown with ratings separated by “/”. EER – Energy Efficient Ratio Units with one rating are 265 volt units. * – Covers All Model Versions Quick Reference 5500 Series Heat Pump with Backup Resistance Heat 5500 Series Control Panel MODEL NUMBER COOLING (Btuh) Voltage 60 hz 1-phase Cooling Watts EER COP Reverse Cycle Heat (Btuh) AZ55H07DA* 7100/6800 230/208 590/565 12.0/12.0 3.5/3.5 6400/6200 AZ55H09DA* 9000/8800 230/208 785/765 11.5/11.5 3.5/3.5 8400/8200 AZ55H12DA* 11800/11600 230/208 1085/1065 10.9/10.9 3.3/3.3 10900/10700 AZ55H15DA* 14700/14400 230/208 1470/1440 10.0/10.0 3.1/3.1 13400/13200 AZ55H07EA* 7100 265 590 12.0 3.5 6400 AZ55H09EA* 9000 265 785 11.5 3.5 8400 AZ55H12EA* 11800 265 1085 10.9 3.3 10900 AZ55H15EA* 14700 265 1470 10.0 3.1 13400 LEGEND COP – Coefficient of Performance EER – Energy Efficient Ratio * – Covers All Model Versions Zoneline® Chassis Nomenclature The Zoneline chassis is identified by a model number defining the type of unit, cooling capacity, electrical information and optional features included on the unit. When specifying or ordering the Zoneline chassis use of this nomenclature will assure receiving the correct unit. A Z 2 5 E0 A Z 5 5 H1 Zoneline® Packaged Terminal Chassis Chassis Series 25 -Deluxe Line Cool/Electric Heat 35 -Deluxe Line Heat Pump 55 -Premium Line Heat Pump Unit Type E -Cooling with Electric Resistance Heat H -Heat Pump with Electric Resistance Heat Nominal Cooling Capacity 07 -7,000 BTUH Cooling 12 - 12,000 BTUH Cooling 09 -9,000 BTUH Coolin...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie