Log:
valutazioni - 2, GPA: 3.5 ( )

Istruzioni per l'uso GBC, Modello ORCA-IV

Produttore : GBC
File Size : 1.03 mb
File Nome : ORCA_IV_IT_OP_MAN.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Harsh chemicals like toluene, acetone or MEK destroy the silicone covering of the rolls. IMPORTANT Exercise care when cleaning the rolls with 80% (or stronger) isopropyl alcohol: · Use only in a well ventilated area. · Wear rubber gloves. · Use only on cool rolls. Cleaning heated rolls can ignite the fumes. IMPORTANT Do not leave the top roll heater on with the roll raised. Heat builds up in a stationary roll and can damage it. IMPORTANT Excess pressure can damage the rolls. Always select the minimum roll pressure necessary to complete the task. IMPORTANT If silicone adhesive contacts the upper or lower roll, remove it IMMEDIATELY using 80 % isopropyl alcohol. It can harden within an hour and ruin the roll. IMPORTANT The operating environment must be free of dust, flammable liquids and vapors. You can be injured by inhaling chemical vapors. Vapor build up or stored flammable liquids can cause a fire. Excessive dust can damage the image transfer laminator. IMPORTANT Do not use a knife or other sharp instrument during installation or while servicing the image transfer laminator. You can cause irreparable damage to the rolls. © GBC Pro-Tech 1998 October ORCA-IV Image Transfer Laminator Operation Manual Safety Safety IMPORTANT Do not attempt to move the image transfer laminator across anything other than a flat, level surface without trained and qualified riggers. You can be crushed or seriously injured. The ORCA-IV Image Transfer Laminator is a large and heavy piece of equipment. It is necessary to employ LICENSED RIGGERS ONLY to move the machine. The image transfer laminator is not designed to be tipped up or sideways in any way. Such action disturbs the exact alignment of the rolling parts of the machine and requires extensive realignment. GBC Pro-Tech’s warranty does not cover malfunction of the equipment due to mishandling and/or tipping. GBC Pro-Tech bears no responsibility for personal injury or damage due to moving the image transfer laminator improperly. WARNING Only a qualified electrician should connect power to the image transfer laminator. You can be severely shocked, electrocuted or cause a fire if power is improperly applied. IMPORTANT Do not operate the image transfer laminator if the power cord is damaged or frayed. You can be severely shocked, electrocuted or cause a fire. Contact a qualified electrician to replace the cord. IMPORTANT Do not allow anything to rest on the power cord. Do not locate the cord where people can walk on it. You or others can be severely shocked, electrocuted or cause a fire. IMPORTANT Do not open the side covers of the machine. Only a qualified service technician should remove the covers. You can be severely shocked, electrocuted, or crushed. IMPORTANT Never operate the machine with side covers open. You can be severely shocked, electrocuted, or crushed. ALWAYS USE GOOD SAFETY PRACTICES WHEN OPERATING OR SERVICING THE IMAGE TRANSFER LAMINATOR AND KNOW HOW TO REACT QUICKLY IN AN EMERGENCY. &DXWLRQ:DUQLQJ/DEHO/RFDWLRQ. On your ORCA-IV Image Transfer Laminator are important safety labels. See Figure 1-5: Locations of Safety Labels for the location of these labels. © GBC Pro-Tech 1998 October Safety ORCA-IV Image Transfer Laminator Operation Manual 1-6 © GBC Pro-Tech 1998 October Figure 1-5: Locations of Safety Labels CAUTION! EXPOSED ROLLER Can cause personal injury. Keep hands, long hair, ties, jewelry and loose clothing away from this area. ® ® PRO-TECH ENGINEERING, INC. Madison, Wisconsin LISTED I.T.E 6N10 Model No. Serial No. VAC Hz Amps Phase Wires MADE IN U.S.A. SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING TO THE SUPPLY 100 90 80 70 60 50 40 30 20 10 100 90 80 70 60 50 40 30 20 10 100 90 80 70 60 50 40 30 20 10 % % % PRO-TECH 100 90 80 70 60 50 40 30 20 10 % PRO-TECH ORCA IV™ 1234 0000 CAL 3200 psi 100 90 80 70 60 50 40 30 20 10 kPa 700 630 560 490 420 350 280 210 140 70 CAL 3200 4 NOTAUS EMERGENCYSTOP ARRETD'URGENCE NOTAUSEMERGENCYSTOPARRETD'URGENCE One Located At Each Roll Load Point (7 Total) Located Inside Cabinet Located Inside Cabinet Located Inside Cabinet On Exterior Panels . 100 PSI . 700 KPa ©1997 HCS, Inc. 800-748-0241 No. 6101-52BVPK Emergency Stop Kick Cables Located Below. Kick or Step on to Stop Laminating Process. Located On Door HIGH LEAKAGE CURRENT! Earth connection essential before connecting supply Located Inside Cabinet Located Inside Cabinet CAUTION FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE 24VDC 6 A/250V 1/4 X 1-1/4 IN [ 5 X 20mm ] 1 A/250V 1/4 X 1-1/4 IN [ 5 X 20mm ] 6 A 1 A 6 A SAFETY INSTRUCTIONS SICHERHEITSRICHTLINIEN CONSIGNES DE SECURITE WARNING ACHTUNG MISE EN GARDE ©1994 Hazard Communication Systems, Inc. 800-748-0241 ©1994 Hazard Communication Systems, Inc. 800-748-0241 WARNING ACHTUNG MISE EN GARDE WARNING ACHTUNG MISE EN GARDE SAFETY INSTRUCTIONS SICHERHEITSRICHTLINIEN CONSIGNES DE SECURITE CAUTION! EXPOSED ROLLER Can cause personal injury. Keep hands, long hair, ties, jewelry...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie