This can be done by connecting the LC-l to the computer and launching LM Programmer. The warm-up and error condition options for the analog output are under the Advanced... settings. For example, if you setup the error condition at 5 V your gauge will display full lean if any problem arises. Please refer to chapter 6.5.1 in the LC-l manual for further information. ilNVOVATS 11-0115B.doc 1/WO VAT M w G2/G4/G5 Air/Fuel Gauge LM-l Quick Start Guide The LM-l's analog output cable has three ends: Red wire is analog output 1, White wire is analog output 2, and the remaining wire is the ground. In these instructions we will be using the white and ground wires. 1. Connect the gauge's BROWN wire to a permanent/constant 12 volt source. 2. Connect the gauge's BLACK ground wire to the LM-l's analog output wire's ground. 3. Connect the gauge's GREEN wire to the white analog output wire. 4. Connect the gauge's WHITE wire to a headlight power wire (a wire that supplies current to the headlights). 5. Connect the gauge's BLUE wire to a switched 12 volt source (ignition switched). 6. Connect the LM-l to the computer and launch LM Programmer. Setup analog output 2 as Ov = 7.35 A/F and 5v = 22.39 A/F. Lastly click on the "Program” button. , LM Programmer Version 3.15 Info/Set AFR | Analog Out 1 Analog Out 2 | RPM-Converter | 1 nn 1.DD Output Ü.DDC Volt at AFP: 7.35 and p.EDO Volt at AFR: 22.35 C use Lambda (• use airfuekatio Factory Defaults Advanced... Program ...