Log:
valutazioni - 2, GPA: 4 ( )

Istruzioni per l'uso Furuno, Modello CH300

Produttore : Furuno
File Size : 3.87 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


• If the D-sub connector is too large to pass through the hole in a bulkhead, etc. remove it, pass the cable through the hole and then reattach the connector. 2. WIRING Note 1 Hull unit 12/24 VDC 12-24 VDCLoudspeaker (w/cable) Motion sensor Clinometer Remote controller Navigation equipment 06S4078 (5/10m) 250V-DPYCYS-2.5 06S4080 (15/30/50m) 06S4081 (3.5/5.2m) DPYCYS-2.5 06S4037 (10m) Note 1: Optional cable between the monitor unit and control unit for separate installation -MJ-A10SPF0002-015 (1.5m) -MJ-A10SPF0002-050 (5m) (5 m) Monitor/control unt CH-302/MU-100C IF-8000 Interface unit * a * b Monitor (User supply) Transceiver unit CH-303 Note 2 a b<15m CH-304 CH-305 Ext. KP MJ-A10SPF0002-0015 0.15 m Note 2 Satellite compass MJ-A6SPF 0012 Note 3 Note 3: MU-151C can be connected for MU-100C. In this case, the monitor and control units should be mounted seprately. Also, the MU-151C requires the independent power. Note 4: Satellite compass SC-50/110 can be connected. See the schematic diagram. Note 4 Wiring, with monitor Interface unit IF-8000 SPEAKER 12-24VDCLoudspeaker (w/cable) Monitor unit Clinometer External monitor Navigation equipment Note 1: Two interface units may be connected. Note 2: For interface unit, the external monitor (user supply) is required. 06S4078 (5/10m) DPYCYS-2.5 06S4037 (10m) Note 2 Note 1 Control unit, rear view Interface unit MJ-A10SPF0002-050 (5m) 06S4078 (5/10m) Max. 15m Remote controller (5m) CONT REM Hull unit 12/24VDC DPYCYS-2.506S4080(15/30/50m) 06S4081 (3.5/5.2m) External monitor * a * b Note 3 *a b<15m Ext. KP Control unit CH-302 Transceiver unit CH-303 CH-304 CH-305 Satellite compass MJ-A6SPF 0012 Note 3 Note 3 Wiring, without monitor 2. WIRING 2.2 Transceiver Unit Connect the cables as shown in the figure below. SC-05WR 06P0255 06P0254 06P0258 J5 J6 J2 06S4080 Hull unit CH-304/CH-305 SPEAKER HULL UNIT DATA/VIDEO OUT MOTION SENSOR Earth 12-24VDC *Note Monitor unit or MU-100C Interface unit IF-8000 Motion sensor MS-100 or Clinometer BS-704 DPYCYS-2.5 Ship's mains 12-24 DCV J3 7P-NH connector (local supply) External KP External loudspeaker To ship's earth*Note + TB1 NMEA/SATELLITE COMPASS Satellite compass SC-50/110, etc. Tie these cables with locking spacer. - *: Fix the braided shield with the clamp. Transceiver unit, internal view Synchronizing Transmission with Echo Sounder or Other Sonar To synchronize transmission of the CH-300 with an echo sounder or other type of sonar, connect it as shown below. H7P-SHF (local supply) Transceiver unit Sonar, E/S Vinyl wire (local supply) AWG22-26 06P0254 J3 3 to 15V KP OUT HULL UNIT clampKPI 3 positive EXT_SW 5 +5V to 15V GND 6 GND Connection of transceiver unit to other sonar/echo sounder Note: Outputting KP of CH-300 to other sonar, echo sounder Transceiver unit 06P0254 J3 KPO GND 2 6 (E/S transmits, SONAR) 12V positive Outputting KP of CH-300 to other sonar, echo sounder 2. WIRING 2.3 Hull Unit Pass the cables to the 06P0257 Board, through the cable protectors. 06P0257 06P0243 J2 J1J3 J1 J2 TB2 Cable from transducer 06S4081 Cable from transceiver unit 06S4080 Power cable 250V-DPYCYS-2.5 Power switch Should always be in up position (ON). Earth Connect to ship's earth. *Note *Note *Note + - Fasten glands securely by hand. Attach the EMI core RFC-4 (supplied) to this cable, and then fix the core to the cable for JI with the cable tie CV-100N (supplied). *Note: Fix the braided shield with cable clamp. Hull unit, inside view Attaching EMI core RFC-4 2.4 Interface Unit Earth NAV Control unit cable MJ-A10SPF0002 VGA monitor Monitor unit cable 06S4078 Transceiver unit cable 06S4078 Connect to ship's earth. DATA/VIDEO IN DATA/VIDEO OUT RGB OUT CONT NMEA (1.5/5 m) The blackbox type requires connection of a VGA monitor, via the interface unit IF-8000. Supply monitor and interconnection cable (Max. length 15 m with Dsub-15P connectors of male, three rows of 15 pins). The monitor used should satisfy the specifications shown below. • VGA type • ANALOG RGB 0.7 Vpp, positive polarity • TTL level H, V, Negative polarity Note 1: Two interface units can be connected to the transceiver unit in parallel. Note 2: When using DATA/VIDEO OUT port, cut and remove the rubber covers as below to attach connectors to the interface unit. Remove the fixing metals. Cut and remove the covers. Note 3: Connect control unit or navigator equipment to either interface unit or monitor unit (supplied by FURUNO). Note 4: When connecting the monitor unit MU-100C to the interface unit, or two interface units in parallel to the transceiver unit, the length of cables should be as shown in the figure on next page. Note that two cables 06S4078 (10 m length) cannot be used. 2. WIRING Transceiver unit External monitor Display unit MU-100CInterface unitA B A+B<15m 06S4078 06S4078 Control unit may be connected to interface unit or display unit. Transceiver unit External monitor External monitor Interface unit Interface unit CA A+C<15m 06S4078 06S4078 Connect control unit to an inter...

Questo manuale è adatto anche per i modelli :
Attrezzature per imbarcazioni - CH-300 (3.87 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie