This can be managed by installing an in-line surge protector vertically +/- 45° as close to the tank as possible. There must be no less than 24" of hose between the inline surge and the canister all of which must be self draining to the tank. Liquid water must not enter the canister from the exterior of the vessel. This can be managed by installing a P-trap or similar device at the vent hardware mounted to the hull. Ullage must be designed into the integrated tank to allow a minimum of 5% of the tanks total volume to remain unfilled with fuel. This allows for the safe expansion of the fuel during a system increase in temperature. © Copyright 2008, Attwood Corporation. Lowell, MI....