Log:
Scaricare : 9   File Size : 4 mb   Produttore : Desa  
Categoria : Attrezzature per imbarcazioni
@name

When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual. KEY NO. PART NUMBER FOR DESCRIPTION QTY.FVSA18M FVSA24M FVDA18M FVDA24M FVDA30M 1 901063-01 901063-01 901063-01 901063-01 901063-01 Brass 3/8 FLR x 1/2 FPT 1 2 901056-01 901056-01 901056-01 901056-01 901056-01 Brass 3/8 FLR x 3/8 MPT Elbow 1 3 901066-01 901066-01 901066-01 901066-01 901066-01 Brass Air Mixer - Natural Gas 1 4 901064-07 901064-02 901064-07 901064-08 901064-04 Natural Gas Injecto

Scaricare : 11   File Size : 4 mb   Produttore : Desa  
Categoria : Attrezzature per imbarcazioni
@name

If you smell gas, STOP! See Safety Information, page 2. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise to the PILOT position and press in. Keep control knob pressed in for five (5) seconds. Note:You may be running this log set for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system. • If control knob does not pop up when released, contact a qua

Scaricare : 23   File Size : 4 mb   Produttore : Desa  
Categoria : Attrezzature per imbarcazioni
@name

16. To help prevent breakage, new logs must be broken-in (see Curing Logs page 9). 17. Turn log set off and let cool before servicing, installing, or repairing. Only a qualified service person should install, service, or repair log set. 18. Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids. 19. Provide adequate clearances around air openings. LOCAL CODES Install and use log set with care. Follow all local codes. In the absence of l

Scaricare : 10   File Size : 4 mb   Produttore : Desa  
Categoria : Attrezzature per imbarcazioni
@name

Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect log set and its individual equipment shutoff valve from gas supply piping system. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either

Scaricare : 9   File Size : 4 mb   Produttore : Desa  
Categoria : Attrezzature per imbarcazioni
@name

When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual. KEY NO. PART NUMBER FOR DESCRIPTION QTY.FSLR18 FSLR24 FDLCR18 FDLCR24 FDLCR30 1 — — 901565-03 901566-03 901567-03 Bottom Rear Log 1 2 — — 901656-01 901657-01 901658-01 Bottom Front Log 1 3 — — 901666-01 901667-01 901668-01 Bottom Front Log 1 4 — — 901619-01 901619-01 901619-01 FS-12Y Top Log 1 5 — — 901617-01 901617-01 901617-01 FS-16 Top Log 1 6 — — 901612-01 901612-01 901612-01 FS-17 Top Log

Scaricare : 10   File Size : 4 mb   Produttore : Desa  
Categoria : Attrezzature per imbarcazioni
@name

5. Remove the burner inlet fitting from the gas control assembly (see Figure 8). DO NOT remove the orifice from this fitting. The propane/LP burner inlet fitting is included in the hardware kit (see Figure 9). 6. Be sure to use the correct orifice for your appliance. The orifice kit included with this appliance contains an orifice installed in an air mixer fitting. 7. Using thread sealant (resistant to the action of propane/LP gas) on smaller end of fitting, screw the burner inlet fitting into t

Scaricare : 8   File Size : 4 mb   Produttore : Desa  
Categoria : Attrezzature per imbarcazioni
@name

PILOT ASSEMBLY The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. The pilot is located on the back right hand side of the burner. The thermocouple should be fully enveloped in the flame. The flame should not be lifting off of the thermocouple element. If your pilot assembly does not meet these requirements: • Access the pilot adjustment screw through slot in valve cover. Turn adjustment screw clockwise to decrease or coun

Scaricare : 9   File Size : 4 mb   Produttore : Desa  
Categoria : Attrezzature per imbarcazioni
@name

1. Remove logs, hearth kit, pan materials, and hardware from carton. 2. Remove all protective packaging applied to logs and base for shipment. 3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought the product. PRODUCT FEATURE ON/OFF SAFETY VALVE/PILOT Unit is tested and approved to ANSI Z21.60a-2000 and CSA 2.26a2000 as a vented decorative appliance. It is supplied with the parts and instructions to convert to propane/LP gas use. For more information, vi

Scaricare : 11   File Size : 4 mb   Produttore : Desa  
Categoria : Attrezzature per imbarcazioni
@name

Excessive flame impingement or blockage 4. Improper fuel/air mixture 5. Excessive gas supply/pressure 1. Contact local natural or propane/LP gas company 2. Adjust damper wide open and/or have fireplace and venting professionally cleaned and checked 3. Separate the logs to allow more flame passage 4. Remove any foreign items from the flame pattern and/or check for proper orifice sizing 5. Preheat flue in very cold weather Burner is excessively noisy 1. Passage of air/gas across irregular sur1. Re

Scaricare : 9   File Size : 4 mb   Produttore : Desa  
Categoria : Attrezzature per imbarcazioni
@name

Assembly 1 8 901232-01 901232-01 901232-01 901232-01 901232-01 Gas Line - 12" Aluminum 1 9 901430-01 901430-01 901431-01 901431-01 901431-01 Grate Steps 2 10 901243-01 901243-02 901246-01 901246-02 901246-03 Log Grate 1 11 — — 901681-01 901681-01 901681-01 Burner Strap 1 12 — — 901078-01 901078-01 901078-01 Nut #8/32 1 13 — — 901076-01 901076-01 901076-01 Screw #8/32 x 3/8 1 14 901082-01 901082-01 901082-01 901082-01 901082-01 Regulator 1 15 901066-02 901066-02 901066-02 901066-02 901066-02 Prop





categorie