|
Facilità d'uso
Refer service to a qualified technician. For Models with Internal or External Fuses: For continued protection against fire hazard, replace only with same type and rating of fuse. Instructions d’installation et de securite Pour les modeles sans interrupteur de courant: La prise de courant d’alimentation sera installe pres de l’equipement et sera accessible. Pour tout les modeles: Pas de composants a entretenir a l’interieur. Confiez toute reparation a un technicien qualifie. Pour les modeles equipes de fusibles internes ou externes: Afin d’eviter tout danger d’incendie, ne remplacer qu’avec le meme type et la meme valeur de fusible. Installations- und Sicherheitshinweise Fur Gerate ohne Netzschalter: Die Netzsteckdose soll in der Nahe des Gerates installiert und frei zuganglich sein. Fur alle Gerate: Keine Wartung innerhalb des Gerates notwendig. Reparaturen nur durch einen Fachmann! Fur Gerate mit interner oder externer Sicherung: Fur dauernden Schutz gegen Feuergefahr darf die Sicherung nur gegen eine andere gleichen Typs und gleicher Nennleistung ausgewechselt werden. Instalacion E Instrucciones de Seguridad Modelos Sin Interruptor: La conexion debe ser instalada cerca del equipo y debe ser accesible. Para Todos Los Modelos: Dentro de la unidad , no hay partes para reparar. Llame un tecnico calificado. Modelos con Fusibles Internos o Externos: Para prevenir un incendio, reemplace solo con el mismo tipo de fusible. CE COMPLIANCE All products exported to Europe by Inline, Inc. after January 1, 1997 have been tested and found to comply with EU Council Directive 89/336/EEC. These devices conform to the following standards: EN50081-1 (1991), EN55022 (1987) EN50082-1 (1992 and 1994), EN60950-92 Shielded interconnect cables must be employed with this equipment to ensure compliance with the pertinent Electromagnetic Interference (EMI) and Electromagnetic Compatibility (EMC) standards governing this device. FCC COMPLIANCE This device has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide against harmful interference when equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at their own expense. Product Overview DESCRIPTION The IN1124 Twisted Pair Transmitter / Distribution Amplifier and IN1130 Twisted Pair Receiver / Distribution Amplifier combine to make a system for sending high-resolution RGBHV signals and audio signals up to 500 feet using Category 5 unshielded twisted pair (UTP) cable. By using one IN1124 transmitter and four IN1130 receivers, the VGA and audio signal from one source computer can be split and amplified to drive a local monitor plus up to eight additional displays. The IN1124 / IN1130 twisted pair video / audio transmission system lets A/V system designers and installers take advantage of the compact size, flexibility, and extremely low cost of CAT5 UTP cable. PRODUCT FEATURES IN1124-1 Twisted Pair Transmitter / Distribution Amplifier for High-Resolution Video - features four RJ45 female output ports (for connection to four CAT5 cables) as well as a local monitor output. IN1124-2 Twisted Pair Transmitter / Distribution Amplifier for High-Resolution Video & Audio -provides the same features as the IN1124-1 as well as dual stereo mini connectors: one for stereo audio input, and the other to drive a local audio device. IN1130-1 Twisted Pair Receiver / Distribution Amplifier for High-Resolution Video - can drive two data display devices simultaneously. IN1130-2 Twisted Pair Receiver / Distribution Amplifier for High-Resolution Video & Audio -provides the same features as the IN1130-1, as well as dual mini connectors for mono audio output. High Quality Video - The IN1124 / IN1130 system employs sophisticated video circuitry to maintain excellent video quality with VGA video signals at resolutions as high as 1600 x 1200. A Video Peaking control on the IN1130 receiver lets users fine tune the video compensation to optimize the video image for various cable lengths. Flexible Input Signal Compatibility - In addition to VGA signal compatibility at all resolutions up to 1600 x 1200, the IN1124 / IN1130 system is also compatible with high-resolution analog video RGBHV, RGBS, RGsB signals at a variety of resolutions and refresh rates. By using the appropriate adapter cables (see the table on page 6), the IN1124 / IN1130 system can transmit video and stereo audio signals from MAC, SUN, SGI and other high-resolution workstations. Twisted Pair Cable Compatibility - The IN1124 / IN1130 has been optimized for Category 5 unshielded twisted pair (UTP) cable. However, ...
Questo manuale è adatto anche per i modelli :Ricevitori - IN1130 (462.94 kb)