Log:
valutazioni - 0, GPA: 5 ( )

Istruzioni per l'uso Garmin, Modello 550C

Produttore : Garmin
File Size : 958.97 kb
File Nome : echo_200_300c_500c_550c_OM_EN.pdf
Lingua di insegnamento: en
Vai a scaricare



da questo dispositivo ha anche altre istruzioni :

Facilità d'uso


You can change the depth-range scale on the depth log. Increasing the depth- range scale allows you to view more variations in depth. Decreasing the depth-range scale allows you to view more detail in the variation. When the scale is set to Auto, the depth range automatically adjusts to display all the log values within the selected duration. 1. Select MENU > Depth Log Options > Scale. 2. Select a depth-range scale. echo 200, echo 300c, echo 500c, and echo 550c Owner’s Manual Viewing Pages Viewing the Temperature Log Page The Temperature Log page displays a graphic log of water temperature readings over time. 1. From any page, select MENU > Pages > Log. 2. If the temperature log or the split screen log is shown, select MENU > Change Log > Temperature. Setting the Temperature Log Duration Before you can set the temperature log duration, you must open the temperature log (page 7) or the split screen log (page 7). You can change the time scale on the water temperature log. Increasing the time scale allows you to view temperature variations over a longer period of time. Decreasing the time scale allows you to view more detail over a shorter period of time. 1. Select MENU > Temp. Log Options > Duration. 2. Select a duration. Setting the Temperature Log Scale Before you can set the temperature-range scale, you must open the temperature log (page 7) or the split screen log (page 7). You can change the temperature-range scale on the temperature log. Increasing the temperature-range scale allows you to view more variations in temperature. Decreasing the temperature-range scale allows you to view more detail in the variation. When the scale is set to Auto, the temperature range automatically adjusts to display all the log values within the selected duration. 1. Select MENU > Temp. Log Options > Scale. 2. Select a temperature-range scale. Viewing the Depth Log and the Temperature Log Simultaneously. You can view the depth log and temperature log simultaneously on the split screen log. You can adjust the depth log duration (page 6), the depth log scale (page 6), the temperature log duration (page 7), or the temperature log scale (page 7) from this screen. 1. From any page, select MENU > Pages > Log. 2. If the temperature log or the depth log is shown, select MENU > Change Log > Both. echo 200, echo 300c, echo 500c, and echo 550c Owner’s Manual Viewing Pages Flasher Page The Flasher page displays sonar information on a circular depth scale, indicating what is beneath your boat. It is organized as a ring that starts at the top and progresses clockwise. Depth is indicated by the scale inside the ring. Sonar information flashes on the ring when it is received at the depth indicated. The colors indicate different strengths of the sonar return (refer to the table on page 2). From any page, select MENU > Pages > Flasher. Opening the numbers Page The Numbers page displays numeric information instead of a graph. From any page, select MENU > Pages > Numbers. resetting the Odometer to Zero NOTE: The device must be connected to a speed-wheel transducer to use the odometer. From the Numbers page, select MENU > Reset Odometer. . . .Depth at your present location. .Depth scale. echo 200, echo 300c, echo 500c, and echo 550c Owner’s Manual Using the echo Using the echo Sonar Screen Settings The Full Screen page, the Split Zoom page, the Split Frequency page, and the Flasher page are a visual representation of the area beneath your boat. These sonar views can be customized as indicated in the following paragraphs. adjusting the range of the Depth Scale Before you can adjust the range of the depth scale, you must open the Full Screen page (page 4), the Split Zoom page (page 5), the Split Frequency page (page 5), or the Flasher page (page 8). You can adjust the range of the depth scale that appears on the right side of the Full Screen page, the Split Zoom page, and the Split Frequency page, and the inside of the flasher. This setting determines how deep the sonar will search for targets. 1. Select MENU > Range. 2. Select an option: • To allow the device to adjust the range automatically based on the depth, select Auto. • To increase or decrease the range of the depth scale manually, select Manual, select or , then select ENTER. When you set the range on one page, that setting is applied to the other pages. Zoom adjustments You can adjust the zoom of the Full Screen page, the Split Zoom page, and the Split Frequency page manually, or you can allow the device to adjust the zoom automatically. Adjust the zoom manually by selecting the span (amount of sonar data that will be displayed in the zoomed window) and selecting a fixed starting depth. For example, if you select a span of 15 meters and a starting depth of 5 meters, the device will display an area from 5 meters deep to 20 meters deep. When you adjust the zoom automatically, the span is the area that will be displayed on the screen from the contour of the bottom of the water. For exampl...

Questo manuale è adatto anche per i modelli :
Media Players - 500c (958.97 kb)
Sounders - echo 200 (958.97 kb)
Sounders - echo 300C (958.97 kb)
Sounders - echo 500C (958.97 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie