Log:
valutazioni - 3, GPA: 3.7 ( )

Istruzioni per l'uso McCulloch, Modello 7096-H18A01

Produttore : McCulloch
File Size : 1.46 mb
File Nome : MOUS2006_7096H18A01.pdf
Lingua di insegnamento: enes
Vai a scaricare



Facilità d'uso


. . . . . . . . . . . . . . . . . . . .FHH20C Potencia . . . . . . . . . . . . . . . . . . . . . . . . . .13 Amp . . . . . . . . . . . . . . . . . . . . . . . .13Amp La Presion de la Boca (Max.) . . . . . . . . . .1800 psi (125 Bar) . . . . . . . . . . . . . . .2000 psi (140 Bar) La Bompa Presiona . . . . . . . . . . . . . . . . .1160 psi (80 Bar) . . . . . . . . . . . . . . . .1330 psi (91 Bar) Aguas Fluyen (Max.) . . . . . . . . . . . . . . . .1.45 GPM (5.5 L/m) . . . . . . . . . . . . . .1.45 GPM (5.5 L/m) Limpiar las Unidades (Maximum) . . . . . . .1682 . . . . . . . . . . . . . . . . . . . . . . . . . .1928.5 Longitud de la Cuerda (Max.) . . . . . . . . . .35 ft. (10.67m) . . . . . . . . . . . . . . . . . .35 ft. (10.67m) iegue con una manga la Longuitud . . . . .19 ft. (6m) . . . . . . . . . . . . . . . . . . . . . .19 ft. (6m) Angulo de Rociada . . . . . . . . . . . . . . . . . .0°-30° . . . . . . . . . . . . . . . . . . . . . . . . .0°-30. Peso neto . . . . . . . . . . . . . . . . . . . . . . . .20.9 Lbs. (9.5 kg) . . . . . . . . . . . . . . . .31.9 Lbs. (14.5 kg) • P.S. La presion (max.) de la boca se mide en la distancia de 10 cm de la boca. 12 1 - GENERAL INFORMATION - RENSEIGNMENTS GENERAUX INFORMACION GENERAL ONOFF2 1 3 4 5 6 7 8 9 1011 12 13 14 15 16 16 17 18 1. Handle 2. On-Off Switch Trigger Switch 3. Hose Hook 4. High Pressure Outlet 5. Water Inlet (water inlet filter#13 inside) 6. High Pressure Hose 7. Safety Lock 8. Trigger Gun 9. Lance Extension 10. Spray Wand 11. Screw-type female connector 12. Cleaning needle 13. Water Inlet Filter 14. Chemical Tank I 15. Chemical Tank II 16. Holder 17. Accessories Box 18. Upper tank cap 1. Mango de Pistola Disparadora 2. Interruptor Conectado-Desconectado 3. Sostenedor de la manguera 4. Salida de Presion Alta 5. Entrada de agua 6. Manga de Presion Alta 7. Cerradura de seguridad 8. Pistola Disparadora 9. Extension de Lanza 10. Vara Rociadora AltBaja 11. Conectador femenino tipo-enrosca 12. Aguja de limpieza 13. Entrada de Agua con Filtro 14. Tanque Quimico I 15. Tanque Quimico II 16. Sostenedor 17. Caja de los accesorios 18. Tapon de tanque superior E N G L I S H E N G L I S H E S P A N O GROUNDING INSTRUCTIONS This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for the electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with local codes and ordinances. DANGER: Improper connection of the equipment grounding conductor can result in a risk of electrocution. Check with a qualified electrician or service personel if you are in doubt as to wether the outlet is properly grounded. Do not modify the plug provided with the product - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use any type of adapter with this product. GROUND FAULT CIRCUIT INTERRUPTER PROTECTION This pressure washer is provided with a ground-fault circuit-interrupter (GFCI) built into the plug of the power supply cord. This device provides additional protection from the risk of electric shock. Should replacement of the plug or cord become necessary, use only identical replacement parts that include GFCI protection. EXTENSION CORDS Use of extension cords is NOT recommended unless plugged into a GFCI protected outlet. Use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole cord connectors that accept the plug from the product. Use only extension cords that are intended for outdoor use. These extension cords are identified by a marking “Acceptable for use with outdoor appliances; store indoors while not in use.” Use only extension cords having an electrical rating not less than the rating of the product. Do not use damaged extension cords. Examine extension cord before using and replace if damaged. Do not abuse extension cord and do not yank on any cord to disconnect. Keep cord away from heat and sharp edges. Always disconnect the extension cord from the receptacle before diconnecting the product from the extension cord. WARNING: To reduce the risk of electrocution, keep all connections dry and off the ground. Do not touch plug with wet hands. 1-2. GENERAL SAFETY RULES 1. High pressure hose can develop leaks from wear, kinking, abuse, etc. Water spraying from a leak is capable of injecting material into skin. Do not point the pressure washer spray at people or animals. 2. Locate this pressure washer in areas away from combustible materials, combustible fumes or dust. 3. Some chemicals or detergents may be harmful if inhaled or ingested, causing severe nausea, fainting or poisoning. The harmful elements may cause property damage or severe injury. 4. Do not allow children to operate the pressure washer at any time. INSTRUCCIONES DE CONECTAR CON TIERRA Este...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie